DOB09/18/2026FAILRE TO CMPLY W/PREV COMMSSNR'S ORDR CNTAIND IN 073126CE30601NB (CONTROL#359025).REMEDY:COMPLY W/ NEW ORDER
DOB08/04/2026EMERG WRK-OBSERVED ACTIVE EXCAVATION & SOE OF DEEP BRACKET PILES W/ UNDERPIN AT EXP4. OBSERVED DAMAGES, CRACKS, AND SIGNS OF MOVEMENT @ EXP2.OF ADJ. BLDG.POT HAZRD TO SITE,PUBLIC, AND ADJ PROP.REMEDY:COMPLY W/CODE. IMMED RETAIN NYS PE, CS, GC & SSM 2 STAB SITE. SGND&SEALD DOCS. DAILY PE INSPN/RPT. COORD W/ OTHER AGCY
DOB08/03/2026FAILURE TO COMPLY W/PREV COMMISSIONER'S ORDER.COMPLY W/NEW ORDER REMEDY:FAILURE TO COMPLY W/PREV COMMISSIONER'S ORDER CNTAIND IN DOB VIO#073026CE30602YU.COMPLY W/ NEW ORDER
DOB08/03/2026FAILURE TO COMPLY W/PREV COMMISSIONER'S ORDER.COMPLY W/ NEW ORDER REMEDY:FAILURE TO CMPLY W/ PREV COMMISSIONER'S ORDER CNTAIND IN DOB VIO#073026CE30601YU.COMPLY W/ NEW ORDER
DOB07/31/2026FTM. OBSERVED ACTIVE EXCAVATION & SOE OF DEEP BRACKET PILES W/ UNDERPINNING AT EXP4. OBSERVED CONSIDERABLE DAMAGES,CRACKS,AND SIGNS OF MOVEMENT AT EXP2 OF ADJOINING BUILDING.REMEDY:PROVIDE PLUMBNESS SURVEY BY 8/14/26.RETAIN NYS PE TO ESTABLISH SCOPE AND SUPERVISE.
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING, I OBSERVED UNDERPINNING IN PROGRESS AT EXPOSURE #4 ADJACENT BUILDING WITH A SINK HOLE AND LOTS OF CRACKS TO THE ROOF. UPON REVIEW OF THE DOB RECORD IT RE$5K due
DOB07/30/2026FTM/POT HAZARD.OBSERVED ACTIVE EXCAVATION & SOE OF DEEP BRACKET PILES W/UNDERPINNING AT EXP4.OBSERVED CONSIDERABLE DAMAGES, CRACKS,AND SIGNS OF MOVEMENT AT EXP2 OF ADJOINING BUILDING.REMEDY:PROVIDE MONITORING PER BC3309.16 & BC1817.9. SUBMIT INTERPRETATION REPORTS DAILY.
DOB07/30/2026FTM/POT HAZARD.OBSERVED ACTIVE EXCAVATION & SOE OF DEEP BRACKET PILES W/UNDERPINNING AT EXP4.OBSERVED CONSIDERABLE DAMAGES, CRACKS,AND SIGNS OF MOVEMENT AT EXP2 OF ADJOINING BUILDING.REMEDY:SUBMIT ENGINEERING EVALUATION REPORT & STABILIZATION/PROTECTION CONSTRUCTION DOCS BY 11AM , 8/3/26.COORD W/ ADJ BLDG
ECB07/30/2026BC 3310.5.3 AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING AT FOUNDATION/EXCAVATION PHASE, I OBSERVED UNDERPINNING IN PROGRESS, UPON REVIEW OF THE SITE SAFETY MANAGER LOG BOOK IT REVEAL THAT HIS LAST D$5K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING AT FOUNDATION/EXCAVATION, I OBSERVED UNDERPINNING IN PROGRESS AT EXPOSURE#4 ADJACENT BUILDING, INVESTIGATION REVEAL THAT DUE TO INADEQUATE SOE, MONITORING$10K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING AT FOUNDATION/EXCAVATION PHASE, I OBSERVED UNDERPINNING IN PROGRESS AT EXPOSURE #4 ADJACENT BUILDING, UPON REVIEW OF THE DEPARTMENT RECORD IT REVEAL THAT$2K due
ECB07/30/2026AT THE TIME OF MY INSPECTION OF A 17 STORY NEW BUILDING AT FOUNDATION/EXCAVATION PHASE, I OBSERVED UNDERPINNING IN PROGRESS AT EXPOSURE #4 ADJACENT BUILDING. UPON REVIEW OF THE DEPARTMENT RECORD IT REVEAL THAT$2K due
HPD11/24/2025§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
HPD12/04/2024§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
HPD11/28/2023§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
DOB01/27/2023STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION DAMAGE OBSERVED TO HAVE BEEN SUSTAINED TO CELLAR, WATER PENETRATION, EXPOSURE #2 WALL, ALONG WITH CEMENT AND FENCE POST INSTALLED DAMAGED PATIO STONE DUE TO ONGOING CONSTRUCTION WORK AT 65 4TH AVENUE.
HPD11/17/2022§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
HPD03/16/2022§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
DOB06/02/2021STRUCTURE RENDERED NON-COMPLIANT AT TIME OF INSPECTION DAMAGE OBSERVED TO HAVE BEEN SUSTAINED TO CELLAR DUE TO BORIG COMPANY HITTING WATER MAIN AND FLOODING CELLAR THIS WAS CAUSED DUE TO BORING WORK AT 65 4 AVENUE
HPD04/21/2021§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
HPD06/14/2012§ 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER 140 DEGREES IN THE BATHROOM LOCATED AT APT 3, 3rd STORY
HPD06/14/2012§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAILBOXES IN VESTIBULE , 1st STORY
HPD06/14/2012§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY
HPD06/14/2012§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 3, 3rd STORY
HPD06/14/2012§ 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF DRYWALL AND CONSTRUCTION DEBRIS AT PUBLIC HALL, 1st STORY
HPD06/14/2012§ 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 3, 3rd STORY
HPD06/14/2012§ 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 3, 3rd STORY
HPD06/14/2012§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE CABINET IN THE BATHROOM LOCATED AT APT 3, 3rd STORY
HPD06/14/2012§ 27-2026 ADMIN. CODE: REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN THE BATHROOM LOCATED AT APT 3, 3rd STORY
HPD06/14/2012§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY
DOB08/16/1993V-DOB VIOLATION - ACTIVE