← Back
Condo, residential tower (mixed-use, multi-family elevator) [derived]
67 CLINTON STREET
MANHATTAN · BIN 1004231
💬 Discuss this project
1900Year Built
6Stories
RMBuilding Class
R7AZoning
5,056 sfGross Floor Area
3Units
Rent Stabilized12 Open Violations ▸FDNY Report ↗
Condo, residential tower (mixed-use, multi-family elevator) [derived] · 1,010 sf lot · 5.01 FAR built · Flood zone X
Locations of Work
Architecture
Floor 15p · 1 filing · 20 docs
Cellar5p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FLEUR707/08/2026
SSP CONSTRUCTION CORP303/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
QWA STUDIO LLC405/09/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SYED-NAQVI ALTAFElectrical103/21/2026
SYED-NAQVI, ALTAFElectrical103/21/2026
CHEF CREATIVE OFFICE INCGeneral Contractor107/08/2026
WATSON'S PLBG, HTG, & BDGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
QWA STUDIO9293405/09/2025
Building Lifecycle
All (37)Filed (4)Permit Issued (2)Violation (15)Inspection (8)Special Inspection (8)
04/29/2026
Violation issued (HPD, open)
A
11/17/2025
Violation issued (HPD, open)
I
11/10/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/04/2025
Violation issued (HPD, open)
A
05/13/2025
Special inspection requirement — Tenant Protection Plan Compliance
Kun Wu
05/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kun Wu
05/13/2025
Special inspection requirement — Energy Code Compliance Inspections
Kun Wu
05/13/2025
Special inspection requirement — Interior lighting power
Kun Wu
05/13/2025
Special inspection requirement — Lighting controls
Kun Wu
05/09/2025
Filed — Alteration
INTERIOR RENOVATION OF EXISTING RESTAURANT. NEW PARTITION PER FLOOR PLANS. NO CHANGE, EGRESS OF USE OR OCCUPANCY.
M01158094-P2
05/08/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
05/01/2025
Violation issued (ECB, closed)
Unknown
04/29/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
04/24/2025
Filed — Alteration
INTERIOR RENOVATION OF EXISTING RESTAURANT. NEW PARTITION PER FLOOR PLANS. NO CHANGE, EGRESS OF USE OR OCCUPANCY.
M01158094-P1
04/22/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/12/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/07/2025
Permit issued — General Construction
M01158094-I1-GC
01/07/2025
Permit issued — Plumbing
M01158094-S1-PL
12/28/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING RESTAURANT. NEW PARTITION PER FLOOR PLANS. NO CHANGE, EGRESS OF USE OR OCCUPANCY.
M01158094-S1
12/28/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kun Wu
12/28/2024
Special inspection requirement — Tenant Protection Plan Compliance
Kun Wu
12/28/2024
Special inspection requirement — Energy Code Compliance Inspections
Kun Wu
12/19/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING RESTAURANT. NEW PARTITION PER FLOOR PLANS. NO CHANGE, EGRESS OF USE OR OCCUPANCY.
M01158094-I1
11/22/2024
Violation issued (HPD, open)
I
04/01/2024
Violation issued (HPD, open)
A
03/15/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
01/17/2024
Inspection — Pass-Final PL - More than 10 Requested Floors
Pass
View inspection ↗
01/02/2024
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
11/15/2023
Violation issued (HPD, open)
I
03/15/2023
Violation issued (HPD, open)
A
11/02/2022
Violation issued (HPD, open)
I
02/15/2022
Violation issued (HPD, open)
A
02/15/2022
Violation issued (HPD, open)
I
04/01/2021
Violation issued (HPD, open)
A
04/01/2021
Violation issued (HPD, open)
I
10/24/2016
Violation issued (HPD, closed)
I
03/29/2015
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedCHEF CREATIVE OFFICE INC02/07/2025
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG01/07/2025
BISPLISSUEDP.S.I. MECHANICAL03/08/2017
BISEQISSUEDSSP CONSTRUCTION CORP07/11/2016
BISFPISSUEDMASTER FIRE SYSTEMS, INC01/22/2016
BISPLISSUEDP.S.I. MECHANICAL10/21/2015
BISEQISSUEDA-LINE CONSTRUCTION CORP10/02/2015
BISOTISSUEDA-LINE CONSTRUCTION CORP10/02/2015
BISOTISSUEDSHANE PATRICK06/16/2006
BISPLISSUEDBARGAIN PLUMBING INC03/08/2006
BISPLISSUEDBARGAIN PLUMBING INC07/19/2005
BISOTISSUEDSHANE PATRICK07/08/2005
BISOTISSUEDSHANE PATRICK07/08/2005
BISOTISSUEDSHANE PATRICK07/08/2005
BISOTISSUEDSHANE PATRICK07/14/2004
BISOTISSUEDSHANE PATRICK06/21/2004
BISOTISSUEDSHANE PATRICK06/18/2004
BISOTISSUEDSHANE PATRICK12/12/2003
BISMHISSUEDSHANE PATRICK07/14/2003
BISOTISSUEDSHANE PATRICK08/09/2002
1 project · most recent 05/09/2025
Water/Sanitary
FiledStatusContractorScope
05/09/2025Signed-offWATSON'S PLBG, HTG, & BDGWater/Sanitary
2 projects · most recent 05/19/2025
General Wiring
FiledStatusContractorScope
05/19/2025CompleteATMOS ELECTRIC SVCE CORPGeneral Wiring
03/07/2018Permit IssuedDORION NORTON ELECL CONT1 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
11/10/2025Fail-Final General Construction Non-Directive 14FailView ↗
05/08/2025Fail-Final General Construction Non-Directive 14FailView ↗
04/29/2025Fail-Final General Construction Non-Directive 14FailView ↗
04/22/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/12/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/15/2024Pass-Final PL - UndergroundPassView ↗
01/17/2024Pass-Final PL - More than 10 Requested FloorsPassView ↗
01/02/2024Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
05/13/2025Tenant Protection Plan ComplianceKun Wuspecial
05/13/2025Fire-Resistant Penetrations and JointsKun Wuspecial
05/13/2025Energy Code Compliance InspectionsKun Wuprogress
05/13/2025Interior lighting powerKun Wuenergy_progress
05/13/2025Lighting controlsKun Wuenergy_progress
12/28/2024Fire-Resistant Penetrations and JointsKun Wuspecial
12/28/2024Tenant Protection Plan ComplianceKun Wuspecial
12/28/2024Energy Code Compliance InspectionsKun Wuprogress
▾Documents — 71 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/25/2026M01158094-I1Request digital key ↗
08/25/2026M01158094-P2Request digital key ↗
08/25/2026M01158094-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits13
▸BISWORK PERMIT APPLICATION7
03/20/2017140407815Open ↗
07/10/2016140519204Open ↗
01/27/2016122606670Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION6
07/10/2016140519204Open ↗
02/24/2016122606670Open ↗
02/19/2016140407815Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications25
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/25/2026M01158094-P1Open ↗
08/25/2026M01158094-I1Open ↗
08/13/2026M01158094-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/24/2026M01158094-S1Open ↗
08/23/2026M01158094-I1Open ↗
08/23/2026M01158094-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/24/2026M01158094-S1Open ↗
08/24/2026M01158094-S1Open ↗
08/23/2026M01158094-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
05/24/2016122606670Open ↗
02/24/2016122606670Open ↗
01/27/2016122606670Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
07/10/2016140519204Open ↗
02/24/2016122606670Open ↗
09/25/2015140407815Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
02/24/2016122606670Open ↗
06/28/2010120395642Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
07/10/2016140519204Open ↗
09/25/2015140407815Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
07/10/2016140519204Open ↗
09/25/2015140407815Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
06/28/2010120395642Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
02/19/2016140407815Open ↗
02/04/2016140407815Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
05/24/2016122606670Open ↗
▸BISSCHEDULE B - PLUMBING1
09/25/2015140407815Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
07/10/2016140519204Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/25/2026M01158094-P1Open ↗
08/25/2026M01158094-I1Open ↗
08/13/2026M01158094-S1Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
06/28/2010120395642Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/25/2015140407815Open ↗
▸Energy Compliance3
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
07/10/2016140519204Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/25/2015140407815Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
09/25/2015140407815Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
07/10/2016140519204Open ↗
09/25/2015140407815Open ↗
▸Approvals, Objections & Sign-offs3
▸BISADMINISTRATIVE OBJECTIONS1
06/28/2010120395642Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
03/20/2017140407815Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/24/2016122606670Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT4
05/24/2016122606670Open ↗
02/24/2016122606670Open ↗
09/25/2015140407815Open ↗
Showing 3 of 4 on file for this type
▸BISDEPT OF FINANCE VERIFICATION1
06/28/2010120395642Open ↗
▸Filing & Intake Forms5
▸BISEFILING JOB APPLICATION COVER SHEET2
07/10/2016140519204Open ↗
09/25/2015140407815Open ↗
▸BISEFILING COVER SHEET2
02/24/2016122606670Open ↗
06/28/2010120395642Open ↗
▸BISADDITIONAL INFORMATION1
02/19/2016140407815Open ↗