← Back
QUEENS
678 VIRGINIA STREET
QUEENS · Far Rockaway-Bayswater · BIN 4833649
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
0 Open ViolationsFDNY Report ↗
Flood zone X500
Locations of Work
ArchitectureStructuralCivil
Permit Issued — active, not yet Signed-off
Floor 1Under Construction8p · 1 filing · 20 docs
CellarUnder Construction32p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AZCONA203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WARREN MEISTER ARCHITECTS, PC603/14/2026
BGM ENGINEERING205/09/2024
VALENTINO POMPEO ARCHITECT, P.C.306/06/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPEDIA BUILDING SOLUTION803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALL-BORO REHAB CONSTRCT CGeneral Contractor304/09/2026
ALL-ISLAND IRRIGATION INCGeneral Contractor207/08/2026
MJH ENERGY CONSULTING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DAVID KATZ, P.E.6087403/14/2026
RAAD7727305/16/2024
C.M. TESTING LABORATORY,1352206/06/2022
Building Lifecycle
All (88)Filed (11)Permit Issued (6)Violation (2)Objection (39)Special Inspection (30)
04/03/2026
Objection raised — Scope
04/03/2026
Objection resolved — Addressed
04/03/2026
Objection raised — Plumbing
03/14/2026
Filed — New Building
MECHANICAL PLANS HEREWITH BEING FILED
Q00552707-P1
02/18/2025
Permit issued — Earth Work
Q00552707-S4-FO-EA
02/13/2025
Permit issued — Support of Excavation
Q00552707-S6-SE
02/11/2025
Permit issued — General Construction
Q00552707-I1-GC
05/20/2024
Objection resolved — Addressed
05/16/2024
Filed — New Building
MECHANICAL PLANS HEREWITH BEING FILED
Q00552707-S9
05/16/2024
Filed — New Building
MECHANICAL PLANS HEREWITH BEING FILED
Q00552707-S8
05/16/2024
Filed — New Building
MECHANICAL PLANS HEREWITH BEING FILED
Q00552707-S7
05/15/2024
Objection raised — Other
05/09/2024
Filed — New Building
MECHANICAL PLANS HEREWITH BEING FILED
Q00552707-S6
05/09/2024
Filed — New Building
MECHANICAL PLANS HEREWITH BEING FILED
Q00552707-S4
05/08/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
NICHOLAS AZADIAN
05/08/2024
Special inspection requirement — HVAC-R and service water heating equipment
NICHOLAS AZADIAN
05/08/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NICHOLAS AZADIAN
05/08/2024
Special inspection requirement — Energy Code Compliance Inspections
NICHOLAS AZADIAN
05/08/2024
Special inspection requirement — HVAC-R and service water heating system controls
NICHOLAS AZADIAN
05/08/2024
Special inspection requirement — Energy Code Compliance Inspections
NICHOLAS AZADIAN
05/08/2024
Special inspection requirement — HVAC-R and service water heating equipment
NICHOLAS AZADIAN
05/08/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
NICHOLAS AZADIAN
05/08/2024
Special inspection requirement — Ventilation and air distribution system
NICHOLAS AZADIAN
05/08/2024
Special inspection requirement — HVAC-R and service water heating system controls
NICHOLAS AZADIAN
04/17/2024
Special inspection requirement — Final
NICHOLAS AZADIAN
04/17/2024
Special inspection requirement — Sprinkler Systems
NICHOLAS AZADIAN
04/17/2024
Special inspection requirement — Mechanical Systems
NICHOLAS AZADIAN
04/11/2024
Special inspection requirement — Electric vehicle service equipment requirements
David Katz
04/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
David Katz
04/11/2024
Special inspection requirement — Air barrier — testing
David Katz
04/27/2023
Objection raised — Zoning
04/27/2023
Objection resolved — Addressed
04/27/2023
Objection raised — Scope
04/27/2023
Objection resolved — Addressed
04/27/2023
Objection raised — Scope
04/27/2023
Objection resolved — Addressed
02/01/2023
Permit issued — General Construction
Q00717607-I1-GC
01/20/2023
Objection raised — Zoning
01/20/2023
Objection resolved — Addressed
01/20/2023
Objection raised — Zoning
01/20/2023
Objection resolved — Addressed
10/21/2022
Violation issued (ECB, closed)
Construction
07/08/2022
Permit issued — Plumbing
Q00717607-S1-PL
07/05/2022
Permit issued — General Construction
Q00717607-I1-GC
06/22/2022
Special inspection requirement — Subgrade Inspections
JOHN SEMIOLI
06/22/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
SAMER ABOU-GHAIDA
06/22/2022
Special inspection requirement — Concrete - Cast-In-Place
JOHN SEMIOLI
06/20/2022
Objection resolved — Addressed
06/20/2022
Objection resolved — Addressed
06/07/2022
Objection raised — Scope
06/07/2022
Objection raised — Inspections
06/06/2022
Filed — Alteration
APPLICATION FILED FOR THE INSTALLATION OF INDOOR IN-GROUND SWIMMING POOL. FILED IN CONJUNCTION WITH NB APPLICATION # Q00552707. ALL WORK IS AS PER PLANS SUBMITTED HEREWITH. NO CHANGE IN USE, BULK, OCCUPANCY OR EGRESS.
Q00717607-P1
06/02/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
06/02/2022
Special inspection requirement — Subgrade Inspections
JOHN SEMIOLI
06/02/2022
Special inspection requirement — Concrete - Cast-In-Place
JOHN SEMIOLI
05/09/2022
Filed — Alteration
APPLICATION FILED FOR THE INSTALLATION OF INDOOR IN-GROUND SWIMMING POOL. FILED IN CONJUNCTION WITH NB APPLICATION # Q00552707. ALL WORK IS AS PER PLANS SUBMITTED HEREWITH. NO CHANGE IN USE, BULK, OCCUPANCY OR EGRESS.
Q00717607-S1
04/27/2022
Special inspection requirement — HVAC-R and service water heating equipment
JOHN SEMIOLI
04/27/2022
Special inspection requirement — Energy Code Compliance Inspections
JOHN SEMIOLI
04/27/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
JOHN SEMIOLI
04/27/2022
Special inspection requirement — HVAC-R and service water heating system controls
JOHN SEMIOLI
Latest 60 of 88 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWEarth WorkPermit IssuedALL-BORO REHAB CONSTRCT C02/18/2025
DOB NOWSupport of ExcavationPermit IssuedALL-BORO REHAB CONSTRCT C02/13/2025
DOB NOWGeneral ConstructionPermit IssuedALL-BORO REHAB CONSTRCT C02/11/2025
DOB NOWGeneral ConstructionPermit IssuedALL-ISLAND IRRIGATION INC02/01/2023
DOB NOWPlumbingPermit IssuedMJH ENERGY CONSULTING INC07/08/2022
DOB NOWGeneral ConstructionPermit IssuedALL-ISLAND IRRIGATION INC07/05/2022
1 project · most recent 03/14/2026
Heating and Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
03/14/2026Permit IssuedALL-BORO REHAB CONSTRCT CHeating and Air Conditioning Systems, Heating Systems
Heat / Cool
Lg ARUM036GSS5 36,000 BTU · Vrf Outdoor ×1
Heating
Reznor EGW 300 CFM · Electric Heater ×2
1 project · most recent 03/14/2026
Steel Concrete
FiledStatusContractorScope
03/14/2026Permit IssuedALL-BORO REHAB CONSTRCT CSteel, Concrete
▾Special Inspection Requirements (DOB NOW) — 44
DateRequirementInspectorRole
05/08/2024HVAC-R and service water piping design and insulationNICHOLAS AZADIANenergy_progress
05/08/2024HVAC-R and service water heating equipmentNICHOLAS AZADIANenergy_progress
05/08/2024Fire-Resistant Penetrations and JointsNICHOLAS AZADIANspecial
05/08/2024Energy Code Compliance InspectionsNICHOLAS AZADIANprogress
05/08/2024HVAC-R and service water heating system controlsNICHOLAS AZADIANenergy_progress
05/08/2024Energy Code Compliance InspectionsNICHOLAS AZADIANprogress
05/08/2024HVAC-R and service water heating equipmentNICHOLAS AZADIANenergy_progress
05/08/2024HVAC-R and service water piping design and insulationNICHOLAS AZADIANenergy_progress
05/08/2024Ventilation and air distribution systemNICHOLAS AZADIANenergy_progress
05/08/2024HVAC-R and service water heating system controlsNICHOLAS AZADIANenergy_progress
04/17/2024FinalNICHOLAS AZADIANprogress
04/17/2024Sprinkler SystemsNICHOLAS AZADIANspecial
04/17/2024Mechanical SystemsNICHOLAS AZADIANspecial
04/11/2024Electric vehicle service equipment requirementsDavid Katzenergy_progress
04/11/2024Fire-Resistant Penetrations and JointsDavid Katzspecial
04/11/2024Air barrier — testing David Katzenergy_progress
06/22/2022Subgrade InspectionsJOHN SEMIOLIspecial
06/22/2022Subsurface Investigations (Borings/Test Pits)SAMER ABOU-GHAIDAspecial
06/22/2022Concrete - Cast-In-PlaceJOHN SEMIOLIspecial
06/02/2022Subsurface Investigations (Borings/Test Pits)—special
06/02/2022Subgrade InspectionsJOHN SEMIOLIspecial
06/02/2022Concrete - Cast-In-PlaceJOHN SEMIOLIspecial
04/27/2022HVAC-R and service water heating equipmentJOHN SEMIOLIenergy_progress
04/27/2022Energy Code Compliance InspectionsJOHN SEMIOLIprogress
04/27/2022HVAC-R and service water piping design and insulationJOHN SEMIOLIenergy_progress
Latest 25 of 44.
▾Documents — 90 on file (BIS + DOB NOW)
▸Plans & Drawings13
▸DOB NOWPlans/Sketch13
08/26/2026Q00717607-I1Request digital key ↗
08/26/2026Q00717607-S1Request digital key ↗
08/17/2026Q00552707-Z2Request digital key ↗
Showing 3 of 13 on file for this type
▸Applications & Permits2
▸BISWORK PERMIT APPLICATION1
06/23/2021421776046Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
11/09/2020421776046Open ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00552707-I1Open ↗
08/13/2026Q00552707-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/13/2026Q00552707-P1Open ↗
08/13/2026Q00552707-I1Open ↗
▸Seals & Professional Certifications37
▸DOB NOWDPL-1: Design Professional Seal & Signature13
08/26/2026Q00717607-P1Open ↗
08/26/2026Q00717607-S1Open ↗
08/26/2026Q00717607-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
09/23/2026Q00552707-S3Open ↗
09/16/2026Q00552707-S9Open ↗
09/16/2026Q00552707-S9Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature11
09/23/2026Q00552707-S3Open ↗
09/16/2026Q00552707-S9Open ↗
09/02/2026Q00717607-I1Open ↗
Showing 3 of 11 on file for this type
▸Trade Schedules & Equipment6
▸BISSEWER CUT-OFF2
06/23/2021421776046Open ↗
06/23/2021421776046Open ↗
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026Q00552707-I1Open ↗
08/13/2026Q00552707-P1Open ↗
▸BISGAS CUT-OFF1
06/23/2021421776046Open ↗
▸BISELECTRIC CUT-OFF1
06/23/2021421776046Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist2
08/13/2026Q00552707-I1Open ↗
08/13/2026Q00552707-P1Open ↗
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE1
06/23/2021421776046Open ↗
▸BISHPD: SRO MD CERTIFICATE OF NO HARASSMENT1
06/23/2021421776046Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00552707-I1Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/23/2021421776046Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026Q00717607-P1Open ↗
08/13/2026Q00717607-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00717607-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00717607-I1Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION2
06/23/2021421776046Open ↗
06/23/2021421776046Open ↗
▸BISTAP LETTER - DOM SVC : DEP-DOM1
06/23/2021421776046Open ↗
▸BISLANDMARKS APPROVAL1
06/23/2021421776046Open ↗
▸Cost, Insurance & Ownership4
▸BISDEPT OF FINANCE VERIFICATION1
06/23/2021421776046Open ↗
▸BISPROJECT-SPECIFIC GL INSURANCE1
06/23/2021421776046Open ↗
▸DOB NOWCertificate of Insurance1
08/13/2026Q00552707-I1Open ↗
▸DOB NOWCertification by Insurance Broker or Agency1
08/13/2026Q00552707-I1Open ↗
▸Filing & Intake Forms3
▸BISBOROUGH INTAKE FORM2
06/23/2021421776046Open ↗
11/09/2020421776046Open ↗
▸BISEFILING COVER SHEET1
11/09/2020421776046Open ↗
▸Other Documents7
▸DOB NOWSite Survey: Initial2
08/13/2026Q00552707-Z2Open ↗
08/13/2026Q00552707-P1Open ↗
▸DOB NOWAdjoining Owners Notification2
08/13/2026Q00552707-S6Open ↗
08/13/2026Q00552707-S4Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00552707-P1Open ↗
08/13/2026Q00552707-I1Open ↗
▸DOB NOWAdditional Insured Authorizations1
08/13/2026Q00552707-I1Open ↗