← Back
Two family brick
68-30 78 STREET
QUEENS · Middle Village · BIN 4092024
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R4Zoning
2,160 sfGross Floor Area
2Units
Two family brick · 2,400 sf lot · 0.9 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GREEN DESIGN204/08/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PHOENIX SUTTON STR INCGeneral Contractor307/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BUTTERFIELD & O'CONNOR4189104/07/2021
Building Lifecycle
All (9)Filed (2)Permit Issued (2)Signed Off (2)Special Inspection (3)
07/01/2021
Signed off — Alteration
NEW BRICK VENEER AND NEW STUCCO WORK NO CHANGE IN USE EGRESS OR OCCUPANCY
Q00495723-I1
06/30/2021
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE.
Q00500198-I1
04/23/2021
Permit issued — Sidewalk Shed
Q00500198-I1-SH
04/13/2021
Permit issued — General Construction
Q00495723-I1-GC
04/08/2021
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE.
Q00500198-I1
04/07/2021
Filed — Alteration
NEW BRICK VENEER AND NEW STUCCO WORK NO CHANGE IN USE EGRESS OR OCCUPANCY
Q00495723-I1
03/31/2021
Special inspection requirement — Masonry
BRIAN T. O'CONNOR
03/31/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
BRIAN T. O'CONNOR
03/31/2021
Special inspection requirement — Final
BRIAN T. O'CONNOR
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSidewalk ShedSigned-offPHOENIX SUTTON STR INC04/23/2021
DOB NOWGeneral ConstructionSigned-offPHOENIX SUTTON STR INC04/13/2021
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
03/31/2021MasonryBRIAN T. O'CONNORspecial
03/31/2021Structural Stability – Alterations of existing buildingsBRIAN T. O'CONNORspecial
03/31/2021FinalBRIAN T. O'CONNORprogress
▾Documents — 8 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026Q00495723-I1Request digital key ↗
08/27/2026Q00500198-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q00495723-I1Open ↗
08/13/2026Q00500198-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026Q00495723-I1Open ↗
08/26/2026Q00495723-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/26/2026Q00495723-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00495723-I1Open ↗