← Back
One family attached or semi-detached
68 STERLING STREET
BROOKLYN · BIN 3034888
💬 Discuss this project
1930Year Built
2Stories
A5Building Class
R5Zoning
2,640 sfGross Floor Area
1Units
One family attached or semi-detached · 2,625 sf lot · 1.01 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Roof23p · 2 filings · 20 docs
Floor 224p · 2 filings · 20 docs
Floor 124p · 2 filings · 20 docs
Cellar23p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
USA DEVELOPMENT2107/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/16/2023$2.5M—— → —$956/sf building
04/27/2022$1.6M—Private party → NEW BROOKLYN NY LLC$591/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
L & C ASSOCIATES812/05/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
L&C ASSOCIATES803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
STELLAR INDUSTRIES INCGeneral Contractor407/08/2026
POWER SURGE ELECTRIC, INCElectrical103/22/2026
HORBRIDGE PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LAM AND CO CONSULTING LLC8065411/29/2022
Building Lifecycle
All (48)Filed (8)Permit Issued (3)Signed Off (2)Inspection (7)Special Inspection (28)
01/23/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/16/2023
Signed off — Alteration CO
FILING FOR MECHANICAL WORK TYPE IN CONJUNCTION WITH ALT1 GC JOB# B00725206. CONVERTING EXISTING TWO (2) DWELLING UNITS TO ONE (1) DWELLING UNIT. ADD NEW BULKHEAD TO EXISTING TWO (2) STORIES BUILDING WITH CELLAR.
B00725206-S1
01/09/2023
Permit issued — Mechanical Systems
B00725206-S1-MS
12/27/2022
Signed off — Alteration
FILING FOR PLUMBING WORK TYPE IN CONJUNCTION WITH ALT 1 GC JOB# B00725206-I1
B00786906-I1
12/19/2022
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/14/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHI WAI CHUNG
12/14/2022
Special inspection requirement — Energy Code Compliance Inspections
CHI WAI CHUNG
12/14/2022
Special inspection requirement — Interior lighting power
CHI WAI CHUNG
12/14/2022
Special inspection requirement — Fenestration areas
CHI WAI CHUNG
12/14/2022
Special inspection requirement — Fenestration air leakage
CHI WAI CHUNG
12/14/2022
Special inspection requirement — Insulation placement and R values
CHI WAI CHUNG
12/14/2022
Special inspection requirement — Air barrier - visual inspection
CHI WAI CHUNG
12/14/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
CHI WAI CHUNG
12/09/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/06/2022
Special inspection requirement — HVAC-R and service water heating equipment
CHI WAI CHUNG
12/06/2022
Special inspection requirement — Energy Code Compliance Inspections
CHI WAI CHUNG
12/06/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
CHI WAI CHUNG
12/06/2022
Special inspection requirement — HVAC-R and service water heating system controls
CHI WAI CHUNG
12/05/2022
Filed — Alteration
FILING FOR PLUMBING WORK TYPE IN CONJUNCTION WITH ALT 1 GC JOB# B00725206-I1
B00786906-P2
12/02/2022
Special inspection requirement — Energy Code Compliance Inspections
CHI WAI CHUNG
12/02/2022
Special inspection requirement — HVAC-R and service water heating system controls
CHI WAI CHUNG
12/02/2022
Special inspection requirement — HVAC-R and service water heating equipment
CHI WAI CHUNG
12/02/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
CHI WAI CHUNG
12/01/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/30/2022
Filed — Alteration CO
FILING FOR MECHANICAL WORK TYPE IN CONJUNCTION WITH ALT1 GC JOB# B00725206. CONVERTING EXISTING TWO (2) DWELLING UNITS TO ONE (1) DWELLING UNIT. ADD NEW BULKHEAD TO EXISTING TWO (2) STORIES BUILDING WITH CELLAR.
B00725206-P3
11/29/2022
Filed — Alteration CO
FILING FOR MECHANICAL WORK TYPE IN CONJUNCTION WITH ALT1 GC JOB# B00725206. CONVERTING EXISTING TWO (2) DWELLING UNITS TO ONE (1) DWELLING UNIT. ADD NEW BULKHEAD TO EXISTING TWO (2) STORIES BUILDING WITH CELLAR.
B00725206-P2
11/29/2022
Filed — Alteration
FILING FOR PLUMBING WORK TYPE IN CONJUNCTION WITH ALT 1 GC JOB# B00725206-I1
B00786906-P1
11/29/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
CHI WAI CHUNG
11/29/2022
Special inspection requirement — Energy Code Compliance Inspections
CHI WAI CHUNG
11/29/2022
Special inspection requirement — Air barrier - visual inspection
CHI WAI CHUNG
11/29/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
CHI WAI CHUNG
11/29/2022
Special inspection requirement — Fenestration areas
CHI WAI CHUNG
11/29/2022
Special inspection requirement — Insulation placement and R values
CHI WAI CHUNG
11/29/2022
Special inspection requirement — Fenestration air leakage
CHI WAI CHUNG
11/29/2022
Special inspection requirement — Interior lighting power
CHI WAI CHUNG
11/29/2022
Special inspection requirement — Energy Code Compliance Inspections
CHI WAI CHUNG
11/29/2022
Special inspection requirement — HVAC-R and service water heating equipment
CHI WAI CHUNG
11/29/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHI WAI CHUNG
11/29/2022
Special inspection requirement — HVAC-R and service water heating system controls
CHI WAI CHUNG
10/11/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/11/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/11/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/29/2022
Filed — Alteration CO
FILING FOR MECHANICAL WORK TYPE IN CONJUNCTION WITH ALT1 GC JOB# B00725206. CONVERTING EXISTING TWO (2) DWELLING UNITS TO ONE (1) DWELLING UNIT. ADD NEW BULKHEAD TO EXISTING TWO (2) STORIES BUILDING WITH CELLAR.
B00725206-S1
09/26/2022
Permit issued — General Construction
B00725206-I1-GC
09/08/2022
Filed — Alteration CO
FILING FOR MECHANICAL WORK TYPE IN CONJUNCTION WITH ALT1 GC JOB# B00725206. CONVERTING EXISTING TWO (2) DWELLING UNITS TO ONE (1) DWELLING UNIT. ADD NEW BULKHEAD TO EXISTING TWO (2) STORIES BUILDING WITH CELLAR.
B00725206-P1
09/06/2022
Permit issued — Plumbing
B00786906-I1-PL
08/11/2022
Filed — Alteration
FILING FOR PLUMBING WORK TYPE IN CONJUNCTION WITH ALT 1 GC JOB# B00725206-I1
B00786906-I1
05/02/2022
Filed — Alteration CO
FILING FOR MECHANICAL WORK TYPE IN CONJUNCTION WITH ALT1 GC JOB# B00725206. CONVERTING EXISTING TWO (2) DWELLING UNITS TO ONE (1) DWELLING UNIT. ADD NEW BULKHEAD TO EXISTING TWO (2) STORIES BUILDING WITH CELLAR.
B00725206-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offSTELLAR INDUSTRIES INC01/09/2023
DOB NOWGeneral ConstructionPermit IssuedSTELLAR INDUSTRIES INC09/26/2022
DOB NOWPlumbingSigned-offHORBRIDGE PLUMBING & HEAT09/06/2022
BISOTISSUED1ST LIGHT ENERGY INC06/12/2018
1 project · most recent 11/30/2022
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
11/30/2022Signed-offSTELLAR INDUSTRIES INCAir Conditioning Systems, Heating Systems
Cooling
Goodman GM9S800603BN 48,000 BTU · Furnace ×8
GSX130361EH 36,000 BTU · Condensing Unit ×8
Heating
Goodman GM9S800603BN 60,000 BTU · Furnace ×8
2 projects · most recent 12/16/2022
General Wiring
FiledStatusContractorScope
12/16/2022CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
02/02/2018CompleteMAVEN ELECTRIC INC—
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
01/23/2023Pass-Final CND-Occupancy InspectionPassView ↗
12/19/2022Pass-Final CND-Occupancy InspectionPassView ↗
12/09/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/01/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/11/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/11/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/11/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 28
DateRequirementInspectorRole
12/14/2022Fire-Resistant Penetrations and JointsCHI WAI CHUNGspecial
12/14/2022Energy Code Compliance InspectionsCHI WAI CHUNGprogress
12/14/2022Interior lighting powerCHI WAI CHUNGenergy_progress
12/14/2022Fenestration areasCHI WAI CHUNGenergy_progress
12/14/2022Fenestration air leakageCHI WAI CHUNGenergy_progress
12/14/2022Insulation placement and R valuesCHI WAI CHUNGenergy_progress
12/14/2022Air barrier - visual inspectionCHI WAI CHUNGenergy_progress
12/14/2022Fenestration and door U-factor and product ratingsCHI WAI CHUNGenergy_progress
12/06/2022HVAC-R and service water heating equipmentCHI WAI CHUNGenergy_progress
12/06/2022Energy Code Compliance InspectionsCHI WAI CHUNGprogress
12/06/2022HVAC-R and service water piping design and insulationCHI WAI CHUNGenergy_progress
12/06/2022HVAC-R and service water heating system controlsCHI WAI CHUNGenergy_progress
12/02/2022Energy Code Compliance InspectionsCHI WAI CHUNGprogress
12/02/2022HVAC-R and service water heating system controlsCHI WAI CHUNGenergy_progress
12/02/2022HVAC-R and service water heating equipmentCHI WAI CHUNGenergy_progress
12/02/2022HVAC-R and service water piping design and insulationCHI WAI CHUNGenergy_progress
11/29/2022HVAC-R and service water piping design and insulationCHI WAI CHUNGenergy_progress
11/29/2022Energy Code Compliance InspectionsCHI WAI CHUNGprogress
11/29/2022Air barrier - visual inspectionCHI WAI CHUNGenergy_progress
11/29/2022Fenestration and door U-factor and product ratingsCHI WAI CHUNGenergy_progress
11/29/2022Fenestration areasCHI WAI CHUNGenergy_progress
11/29/2022Insulation placement and R valuesCHI WAI CHUNGenergy_progress
11/29/2022Fenestration air leakageCHI WAI CHUNGenergy_progress
11/29/2022Interior lighting powerCHI WAI CHUNGenergy_progress
11/29/2022Energy Code Compliance InspectionsCHI WAI CHUNGprogress
Latest 25 of 28.
▾Documents — 85 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/28/2026B00786906-I1Request digital key ↗
08/28/2026B00786906-P2Request digital key ↗
08/28/2026B00786906-P1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
02/13/2018340583416Open ↗
▸BISWORK PERMIT APPLICATION1
06/12/2018340583416Open ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026B00725206-I1Open ↗
08/13/2026B00725206-P1Open ↗
08/13/2026B00725206-P2Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00725206-I1Open ↗
▸Seals & Professional Certifications21
▸DOB NOWProgress Inspector Seal & Signature10
09/01/2026B00725206-I1Open ↗
09/01/2026B00725206-I1Open ↗
08/28/2026B00786906-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/28/2026B00786906-I1Open ↗
08/28/2026B00786906-P1Open ↗
08/28/2026B00786906-P2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B00725206-I1Open ↗
08/23/2026B00725206-P2Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
02/13/2018340583416Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist3
08/28/2026B00725206-P2Open ↗
08/28/2026B00725206-P1Open ↗
08/28/2026B00725206-I1Open ↗
▸BISTENANT PROTECTION PLAN AND NOTES1
02/13/2018340583416Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00725206-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/28/2026B00786906-I1Open ↗
08/28/2026B00786906-P2Open ↗
08/28/2026B00786906-P1Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/13/2018340583416Open ↗
▸Energy Compliance8
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
03/30/2022340583416Open ↗
02/13/2018340583416Open ↗
02/13/2018340583416Open ↗
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026B00786906-I1Open ↗
08/13/2026B00725206-I1Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
03/30/2022340583416Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
02/13/2018340583416Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
03/30/2022340583416Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
03/30/2022340583416Open ↗
02/13/2018340583416Open ↗
02/13/2018340583416Open ↗
▸Approvals, Objections & Sign-offs3
▸BISFINAL ELECTRICAL SIGNOFF1
03/31/2022340583416Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
03/31/2022340583416Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/31/2022340583416Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
02/13/2018340583416Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
03/30/2022340583416Open ↗
▸Filing & Intake Forms5
▸BISADDITIONAL INFORMATION4
06/07/2018340583416Open ↗
05/23/2018340583416Open ↗
04/23/2018340583416Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
02/13/2018340583416Open ↗
▸Other Documents15
▸DOB NOWProperty Ownership Certification5
08/28/2026B00725206-S1Open ↗
08/28/2026B00725206-P2Open ↗
08/28/2026B00725206-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlot Diagram3
08/13/2026B00725206-P2Open ↗
08/13/2026B00725206-P1Open ↗
08/13/2026B00725206-I1Open ↗
▸DOB NOWSite Survey: Initial3
08/13/2026B00725206-P1Open ↗
08/13/2026B00725206-P2Open ↗
08/13/2026B00725206-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026B00725206-P1Open ↗
08/13/2026B00725206-P2Open ↗
08/13/2026B00725206-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00725206-I1Open ↗