← Back
One story retail building
68 WEST 125 STREET
MANHATTAN · Harlem (South) · BIN 1053483
💬 Discuss this project
1960Year Built
1Stories
K1Building Class
C6-3Zoning
2,422 sfGross Floor Area
1Units
One story retail building · Owner of record: 64 WEST LLC · 2,422 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 19p · 2 filings · 13 docs
Cellar6p · 2 filings · 13 docs
Filed — no permit issued3p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ROJO ASSOCIATES1007/08/2026
DIAMOND BRACES103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EUGENE KHANANOV AIA305/05/2022
CONCORD CONSULTING ENGINEERING PC103/14/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SEVENTH FLOOR SERVICES INGeneral Contractor203/21/2026
ENTERPRISE ELEC'L SYSTEMSElectrical103/22/2026
RITE WAY HEATING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
EUGENE KHANANOV ARCHITECT2816305/05/2022
Building Lifecycle
All (11)Filed (4)Permit Issued (2)Inspection (3)Special Inspection (2)
10/10/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/13/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/05/2022
Filed — Alteration
PROPOSED PLUMBING WORK IN EXISTING COMMERCIAL SPACE AS PER PLANS FILED HEREWITH. NO CHANGE IN ZONING USE GROUP, EGRESS OR OCCUPANCY
M00670766-P1
05/04/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eugene Khananov
05/04/2022
Special inspection requirement — Energy Code Compliance Inspections
Eugene Khananov
03/14/2022
Filed — Alteration
Modifications to an existing HVAC system to match new tenant fit our layout
M00698277-I1
03/10/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/15/2022
Permit issued — Plumbing
M00670766-I1-PL
02/11/2022
Permit issued — General Construction
M00670735-I1-GC
02/01/2022
Filed — Alteration
PROPOSED INTERIOR FIT-OUT OF EXISTING COMMERCIAL SPACE, PER B.B. #2009-025 NO CHANGE IN ZONING USE GROUP, EGRESS OR OCCUPANCY.
M00670735-I1
02/01/2022
Filed — Alteration
PROPOSED PLUMBING WORK IN EXISTING COMMERCIAL SPACE AS PER PLANS FILED HEREWITH. NO CHANGE IN ZONING USE GROUP, EGRESS OR OCCUPANCY
M00670766-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offLS PLUMBING CORP02/15/2022
DOB NOWGeneral ConstructionPermit IssuedSEVENTH FLOOR SERVICES IN02/11/2022
BISOTISSUEDKINGS STAR CONSTRUCTION C11/07/2012
BISEQRE-ISSUEDKINGS STAR CONSTRUCTION C11/07/2012
BISPLISSUEDAVON PLBG & HTG INC06/13/2001
BISOTISSUEDNOVA PLUMB HEAT INC.06/13/2001
BISEQISSUEDKORMAN DESIGN & BUILD02/15/2001
BISOTISSUEDKORMAN DESIGN & BUILD02/15/2001
1 project · most recent 03/14/2022
Air Conditioning Systems Heating Systems
FiledStatusContractorScope
03/14/2022——Air Conditioning Systems, Heating Systems
1 project · most recent 05/05/2022
Water/Sanitary
FiledStatusContractorScope
05/05/2022Signed-offRITE WAY HEATING CORPWater/Sanitary
2 projects · most recent 02/28/2022
General Wiring
FiledStatusContractorScope
02/28/2022CompleteENTERPRISE ELEC'L SYSTEMSGeneral Wiring
12/19/2021Permit IssuedBLZ ELECTRIC INC.1 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
10/10/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/13/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/10/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
05/04/2022Fire-Resistant Penetrations and JointsEugene Khananovspecial
05/04/2022Energy Code Compliance InspectionsEugene Khananovprogress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/02/2026M00670735-I1Request digital key ↗
09/02/2026M00698277-I1Request digital key ↗
09/02/2026M00670766-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
11/13/2012121365753Open ↗
11/13/2012121365753Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
09/14/2012121365753Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/02/2026M00670766-P1Open ↗
09/02/2026M00670766-I1Open ↗
08/13/2026M00698277-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
09/14/2012121365753Open ↗
09/14/2012121365753Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/14/2012121365753Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
09/14/2012121365753Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026M00670766-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026M00670766-P1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/02/2026M00670766-I1Open ↗
09/02/2026M00670766-P1Open ↗
08/13/2026M00670735-I1Open ↗
▸DOB NOWOER: Notice to Proceed2
08/13/2026M00670735-I1Open ↗
08/13/2026M00670766-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/14/2012121365753Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
09/14/2012121365753Open ↗
09/14/2012121365753Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
09/14/2012121365753Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/14/2012121365753Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/14/2012121365753Open ↗
▸Other Documents2
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
11/13/2012121365753Open ↗
▸BISENVIRONMENTAL 'E' DEP NOTICE TO PROCEED1
11/21/2012121365753Open ↗