← Back
Five to six families
6812 13 AVENUE
BROOKLYN · Dyker Heights · BIN 3143202
💬 Discuss this project
1920Year Built
3Stories
C2Building Class
R6BZoning
4,020 sfGross Floor Area
5Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Five to six families · Owner of record: W&Z BUILDING LLC · 1,963 sf lot · 2.05 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
W AND Z BUILDING LLC503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HUAN DESIGN INC.211/17/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GRAVITY STUDIO403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GOLDEN TIME CONTRACTING IGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HUAN DESIGN INC7669211/17/2024
Building Lifecycle
All (46)Filed (2)Permit Issued (1)Violation (31)Objection (4)Special Inspection (8)
05/06/2026
Violation issued (HPD, closed)
B
05/06/2026
Violation issued (HPD, open)
B
02/04/2025
Violation issued (ECB, closed)
Construction
12/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ZHENHUAN XU
12/02/2024
Special inspection requirement — Tenant Protection Plan Compliance
12/02/2024
Special inspection requirement — Final
ZHENHUAN XU
12/02/2024
Special inspection requirement — Fire-Resistance Rated Construction
ZHENHUAN XU
11/25/2024
Objection resolved — Addressed
11/22/2024
Objection raised — Other
11/19/2024
Objection raised — Other
11/19/2024
Objection resolved — Addressed
11/17/2024
Filed — Alteration
INTERIOR RENOVATION REPAIR FLOOR BASEBOARD, FLOOR TILE AND REPAIRE/REPLACE WOOD JOIST IN THE EXISTING HALLWAY AREAS. ADDRESS VIOLATION 39108531R;39108533K;39108532Z. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01021204-P1
11/17/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ZHENHUAN XU
11/17/2024
Special inspection requirement — Tenant Protection Plan Compliance
11/17/2024
Special inspection requirement — Final
ZHENHUAN XU
11/17/2024
Special inspection requirement — Fire-Resistance Rated Construction
ZHENHUAN XU
09/19/2024
Permit issued — General Construction
B01021204-I1-GC
03/27/2024
Filed — Alteration
INTERIOR RENOVATION REPAIR FLOOR BASEBOARD, FLOOR TILE AND REPAIRE/REPLACE WOOD JOIST IN THE EXISTING HALLWAY AREAS. ADDRESS VIOLATION 39108531R;39108533K;39108532Z. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01021204-I1
03/12/2024
Violation issued (ECB, closed)
Unknown
03/12/2024
Violation issued (ECB, closed)
Construction
03/12/2024
Violation issued (ECB, closed)
Construction
11/21/2023
Violation issued (HPD, closed)
I
04/26/2023
Violation issued (HPD, open)
A
08/09/2019
Violation issued (HPD, closed)
B
10/06/2015
Violation issued (HPD, closed)
I
02/05/2015
Violation issued (HPD, closed)
I
08/06/2014
Violation issued (HPD, closed)
B
06/12/2013
Violation issued (HPD, closed)
B
06/12/2013
Violation issued (HPD, closed)
B
06/12/2013
Violation issued (HPD, closed)
B
02/23/2011
Violation issued (HPD, closed)
B
05/01/2008
Violation issued (HPD, closed)
A
03/04/2006
Violation issued (HPD, closed)
B
07/01/2005
Violation issued (HPD, closed)
B
07/01/2005
Violation issued (HPD, closed)
B
07/01/2005
Violation issued (HPD, closed)
B
06/24/2003
Violation issued (HPD, closed)
A
06/24/2003
Violation issued (HPD, closed)
B
06/24/2003
Violation issued (HPD, closed)
C
06/24/2003
Violation issued (HPD, closed)
B
06/24/2003
Violation issued (HPD, closed)
B
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/25/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/01/1988
Violation issued (HPD, closed)
C
06/01/1988
Violation issued (HPD, closed)
C
06/01/1988
Violation issued (HPD, closed)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedGOLDEN TIME CONTRACTING I09/19/2024
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
12/02/2024Fire-Resistant Penetrations and JointsZHENHUAN XUspecial
12/02/2024Tenant Protection Plan Compliance—special
12/02/2024FinalZHENHUAN XUprogress
12/02/2024Fire-Resistance Rated ConstructionZHENHUAN XUprogress
11/17/2024Fire-Resistant Penetrations and JointsZHENHUAN XUspecial
11/17/2024Tenant Protection Plan Compliance—special
11/17/2024FinalZHENHUAN XUprogress
11/17/2024Fire-Resistance Rated ConstructionZHENHUAN XUprogress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026B01021204-I1Request digital key ↗
08/14/2026B01021204-P1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
08/25/2026B01021204-P1Open ↗
08/25/2026B01021204-P1Open ↗
08/23/2026B01021204-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026B01021204-P1Open ↗
08/25/2026B01021204-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026B01021204-P1Open ↗
08/23/2026B01021204-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026B01021204-I1Open ↗
08/14/2026B01021204-P1Open ↗