← Back
BuildNYC
Two stories - detached, small or mid-size
684 OAKLAND AVENUE
STATEN ISLAND · BIN 5007915
💬 Discuss this project
1935Year Built
2.5Stories
A1Building Class
R2Zoning
2,400 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 7,120 sf lot · 0.34 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof1p · 1 filing · 20 docs
Floor 310p · 1 filing · 20 docs
Floor 2Extension and renovation15p · 2 filings · 20 docs
Floor 1Extension and renovation18p · 2 filings · 20 docs
CellarExtension and renovation16p · 2 filings · 20 docs
Sub-Basement3p · 1 filing · 20 docs
Site & exterior10p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Jock Deboer, AIA411/23/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A+ Expediting803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Stout HomesGeneral Contractor707/08/2026
Amber Electl ContngElectrical103/22/2026
Ridge ElectricElectrical103/22/2026
Sea Bright SolarGeneral Contractor103/21/2026
Duo Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A Tech Engineering NYC, P6738209/02/2022
Building Lifecycle
10/14/2023
Permit expired, never signed off — Plumbing
The city's record still shows this permit as issued, with no sign-off on its filing
S00681679-I1-PL
03/01/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
02/22/2023
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
S00673214-I1-GC
02/22/2023
Permit expired, never signed off — Structural
The city's record still shows this permit as issued, with no sign-off on its filing
S00673214-S1-ST
02/22/2023
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
S00673214-S4-GC
36 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedStout Homes01/18/2023
DOB NOWStructuralPermit IssuedStout Homes01/17/2023
DOB NOWPlumbingPermit IssuedDuo Plumbing & Heating12/23/2022
DOB NOWGeneral ConstructionPermit IssuedStout Homes12/14/2022
BISOTISSUEDSea Bright Solar04/08/2022
1 project · most recent 09/15/2022
Gas Water/Sanitary
FiledStatusContractorScope
09/15/2022Permit IssuedDuo Plumbing & HeatingGas, Water/Sanitary
2 projects · most recent 07/10/2023
General Wiring
FiledStatusContractorScope
07/10/2023CompleteRidge ElectricGeneral Wiring
04/19/2022CompleteAmber Electl Contng—
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
03/01/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/05/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
02/16/2022Energy Code Compliance Inspectionsanthony santoroprogress
02/02/2022Concrete - Cast-In-Placeanthony santorospecial
02/02/2022Fire-Resistant Penetrations and Jointsanthony santorospecial
02/02/2022Masonryanthony santorospecial
02/02/2022Structural Stability – Alterations of existing buildingsanthony santorospecial
02/02/2022Finalanthony santoroprogress
02/02/2022Energy Code Compliance Inspectionsanthony santoroprogress
02/02/2022Fire-Resistance Rated Constructionanthony santoroprogress
02/02/2022Subsurface Investigations (Borings/Test Pits)anthony santorospecial
02/02/2022Air barrier — testing anthony santoroenergy_progress
02/02/2022Lighting controlsanthony santoroenergy_progress
02/02/2022Insulation placement and R valuesanthony santoroenergy_progress
02/02/2022Lighting in dwelling unitsanthony santoroenergy_progress
02/02/2022Fenestration air leakageanthony santoroenergy_progress
02/02/2022Protection of exposed foundation insulationanthony santoroenergy_progress
02/02/2022Fenestration and door U-factor and product ratingsanthony santoroenergy_progress
02/02/2022Lowest Floor Elevationanthony santoroprogress
52 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account