Locations of Work
Plumbing
Floor 21p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/10/2021$2.3M—Private party → Private party$738/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ROGER BROOME, ARCHITECT P.C.401/30/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EDI CONSULTING GROUP803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JONATHAN R POPEGeneral Contractor303/21/2026
HENRY MYERS P & H, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
H2 CONSULTING PE PC835105/31/2022
Building Lifecycle
All (42)Filed (4)Permit Issued (2)Signed Off (2)Inspection (3)Objection (22)Special Inspection (9)
02/29/2024
Signed off — Alteration
Plumbing work in conjunction with interior renovation to existing 1-family house, as per plans. No change in use, egress or occupancy under this application
B00746278-S1
05/23/2023
Signed off — Alteration
Plumbing work in conjunction with interior renovation to existing 1-family house, as per plans. No change in use, egress or occupancy under this application
B00746278-I1
01/31/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/31/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/30/2023
Filed — Alteration
Plumbing work in conjunction with interior renovation to existing 1-family house, as per plans. No change in use, egress or occupancy under this application
B00746278-P2
12/12/2022
Objection resolved — Addressed
12/11/2022
Objection raised — Scope
11/29/2022
Filed — Alteration
Plumbing work in conjunction with interior renovation to existing 1-family house, as per plans. No change in use, egress or occupancy under this application
B00746278-P1
09/16/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/13/2022
Permit issued — Plumbing
B00746278-S1-PL
07/12/2022
Permit issued — General Construction
B00746278-I1-GC
06/23/2022
Objection raised — Scope
06/23/2022
Objection resolved — Addressed
06/23/2022
Objection raised — Inspections
06/23/2022
Objection resolved — Addressed
06/23/2022
Objection raised — Scope
06/23/2022
Objection resolved — Addressed
06/23/2022
Objection raised — Admin
06/23/2022
Objection resolved — Addressed
06/23/2022
Objection raised — Inspections
06/23/2022
Objection resolved — Addressed
06/23/2022
Objection raised — Inspections
06/23/2022
Objection resolved — Addressed
06/22/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Harry Hong
06/15/2022
Filed — Alteration
Plumbing work in conjunction with interior renovation to existing 1-family house, as per plans. No change in use, egress or occupancy under this application
B00746278-S1
06/08/2022
Objection raised — Fire_Protection
06/08/2022
Objection resolved — Addressed
06/08/2022
Objection raised — Scope
06/08/2022
Objection resolved — Addressed
06/08/2022
Objection raised — Scope
06/08/2022
Objection resolved — Addressed
06/08/2022
Objection raised — Scope
06/08/2022
Objection resolved — Addressed
05/31/2022
Filed — Alteration
Plumbing work in conjunction with interior renovation to existing 1-family house, as per plans. No change in use, egress or occupancy under this application
B00746278-I1
05/26/2022
Special inspection requirement — Final
Roger Broome
05/26/2022
Special inspection requirement — Energy Code Compliance Inspections
Roger Broome
05/26/2022
Special inspection requirement — Fenestration areas
Roger Broome
05/26/2022
Special inspection requirement — Interior lighting power
Roger Broome
05/26/2022
Special inspection requirement — Lighting controls
Roger Broome
05/26/2022
Special inspection requirement — Fenestration air leakage
Roger Broome
05/26/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Roger Broome
05/26/2022
Special inspection requirement — Lighting in dwelling units
Roger Broome
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offHENRY MYERS P & H, INC09/13/2022
DOB NOWGeneral ConstructionSigned-offJONATHAN R POPE07/12/2022
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
01/31/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/31/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/16/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
06/22/2022Structural Stability – Alterations of existing buildingsHarry Hongspecial
05/26/2022FinalRoger Broomeprogress
05/26/2022Energy Code Compliance InspectionsRoger Broomeprogress
05/26/2022Fenestration areasRoger Broomeenergy_progress
05/26/2022Interior lighting powerRoger Broomeenergy_progress
05/26/2022Lighting controlsRoger Broomeenergy_progress
05/26/2022Fenestration air leakageRoger Broomeenergy_progress
05/26/2022Fenestration and door U-factor and product ratingsRoger Broomeenergy_progress
05/26/2022Lighting in dwelling unitsRoger Broomeenergy_progress
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/29/2026B00746278-P2Request digital key ↗
08/15/2026B00746278-P1Request digital key ↗
08/15/2026B00746278-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature7
08/22/2026B00746278-I1Open ↗
08/22/2026B00746278-I1Open ↗
08/22/2026B00746278-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/29/2026B00746278-P1Open ↗
08/29/2026B00746278-S1Open ↗
08/13/2026B00746278-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026B00746278-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/15/2026B00746278-P1Open ↗
08/15/2026B00746278-S1Open ↗
08/13/2026B00746278-I1Open ↗
Showing 3 of 4 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00746278-I1Open ↗