| Owner | Filings | Most Recent |
|---|---|---|
| One45 Lenox | 3 | 03/22/2026 |
| NYC Department of Housing Preservation and Development | 2 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Jfa Architects & Engineers | 6 | 09/16/2026 |
| Elevated Engineering NYC | 4 | 06/30/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Joey Electrical Co | Electrical | 2 | 03/21/2026 |
| Greco Electric | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| Domani Inspection Service | 843 | 2 | 06/30/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| BIS | MH | ISSUED | Done Right Kitchen Exhaus | 03/08/2019 |
| BIS | MH | ISSUED | Wediss Contracting | 12/14/2012 |
| BIS | FP | ISSUED | NY Fire | 11/20/2012 |
| BIS | — | ISSUED | Johnson Design Consulting | 09/18/2012 |
| BIS | PL | ISSUED | C James Plumbing & Heating | 05/03/2012 |
| BIS | OT | ISSUED | Wediss Contracting | 04/20/2012 |
| BIS | OT | ISSUED | A.russo Wrecking | 04/16/2010 |
| BIS | FP | ISSUED | Chief Fire Prevention & Mechanical | 06/22/2007 |
| BIS | PL | ISSUED | Deroza Watson Plumbing Heating | 07/12/2005 |
| BIS | OT | ISSUED | Entire Construction | 06/28/2005 |
| BIS | PL | ISSUED | Mega Plumbing | 01/09/2002 |
| BIS | OT | ISSUED | Leader Improvements | 09/22/2000 |
| BIS | PL | ISSUED | John Cannett | 01/05/2000 |
| BIS | OT | ISSUED | Matthew Painting & Contracting | 08/24/1999 |
| BIS | OT | ISSUED | Bullard Pyrchasing | 08/01/1996 |
| BIS | PL | ISSUED | Avon Plumbing & Heating | 11/28/1995 |
| BIS | SP | ISSUED | Water Plus II | 06/24/1992 |
| BIS | OT | ISSUED | Cra Construction | 04/24/1992 |
| BIS | EQ | ISSUED | JMA & Associates | 09/17/1991 |
| BIS | MH | ISSUED | JMA & Associates | 09/17/1991 |
| BIS | MH | ISSUED | JMA & Associates | 09/16/1991 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 09/16/2026 | Permit Issued | Soho Construction Management | Heating and Air Conditioning Systems, Heating Systems | Heat / Cool Islandaire EZLA09L231E 9,600 BTU · Heat Pump Outdoor ×529 EZLA16L341E 15,000 BTU · Heat Pump Outdoor ×392 Daikin RXYA168AATJA 162,000 BTU · Vrf Outdoor ×6 RXYA96AATJA 96,000 BTU · Vrf Outdoor ×3 RXTA24AAVJU 23,000 BTU · Vrf Outdoor ×2 REYA168AATJA (BC-1 CONTROLLER) 162,000 BTU · Vrf Outdoor ×1 RXTA36AAVJU 34,200 BTU · Vrf Outdoor ×1 RXTA48AAVJU 45,500 BTU · Vrf Outdoor ×1 RXTA60AAVJU 57,500 BTU · Vrf Outdoor ×1 RXYA120AATJA 114,000 BTU · Vrf Outdoor ×1 |
| 09/15/2026 | Permit Issued | Soho Construction Management | Heating and Air Conditioning Systems, Heating Systems | Heat / Cool Daikin EZLA12L341E 12,000 BTU · Wshp ×24 RXYA144AATJA 138,000 BTU · Vrf Outdoor ×8 RXTA24AAVJU 23,000 BTU · Vrf Outdoor ×5 RXYA120AATJA 114,000 BTU · Vrf Outdoor ×4 RXYA96AATJA 92,000 BTU · Vrf Outdoor ×4 RXTA36AAVJU 34,200 BTU · Vrf Outdoor ×2 RXYA168AATJA 162,000 BTU · Vrf Outdoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/16/2026 | — | — | Sprinkler System |
| 09/15/2026 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/16/2026 | — | — | Gas, Storm, Water/Sanitary |
| 09/15/2026 | — | — | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/16/2026 | Permit Issued | Soho Construction Management | Concrete |
| 09/15/2026 | Permit Issued | Soho Construction Management | Concrete |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/16/2026 | Permit Issued | Soho Construction Management | Fence |
| 09/15/2026 | Permit Issued | Soho Construction Management | Fence |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/15/2026 | Permit Issued | Soho Construction Management | Earthwork |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/08/2026 | Metering | — | energy_progress |
| 07/08/2026 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 07/08/2026 | Vestibules | — | energy_progress |
| 07/08/2026 | Air barrier - visual inspection | — | energy_progress |
| 07/08/2026 | Fenestration areas | — | energy_progress |
| 07/08/2026 | Exterior lighting power | — | energy_progress |
| 07/08/2026 | Air barrier continuity plan testing | — | energy_progress |
| 07/08/2026 | Insulation placement and R values | — | energy_progress |
| 07/08/2026 | Fenestration air leakage | — | energy_progress |
| 07/08/2026 | Electrical motors and elevators | — | energy_progress |
| 07/08/2026 | Vestibules | — | energy_progress |
| 07/08/2026 | Maintenance information | — | energy_progress |
| 07/08/2026 | Protection of exposed foundation insulation | — | energy_progress |
| 06/29/2026 | Construction Operations Influencing Adjacent Structures | — | special |
| 06/29/2026 | Subsurface Investigations (Borings/Test Pits) | — | special |
| 06/25/2026 | Concrete - Cast-In-Place | JOHN MCMONAGLE | special |
| 06/25/2026 | Final | JOHN MCMONAGLE | progress |
| 06/25/2026 | Subsurface Conditions – Fill Placement & In-Place Density | JOHN MCMONAGLE | special |
| 06/25/2026 | Footing and Foundation | JOHN MCMONAGLE | progress |
| 06/25/2026 | Deep Foundation Elements | Gregory Moormann | special |
| 05/06/2026 | Construction Operations Influencing Adjacent Structures | — | special |
| 05/06/2026 | Concrete - Cast-In-Place | — | special |
| 05/06/2026 | Post-installed Anchors | — | special |
| 05/06/2026 | Concrete - Cast-In-Place | — | special |
| 05/06/2026 | Post-installed Anchors | — | special |