← Back
Two family frame
69-09 BURCHELL AVENUE
QUEENS · Rockaway Beach-Arverne-Edgemere · BIN 4624748
💬 Discuss this project
2024Year Built
—Stories
B2Building Class
R4AZoning
2,464 sfGross Floor Area
2Units
Two family frame · 3,400 sf lot · 0.72 FAR built · Flood zone AE
Locations of Work
StructuralMechanicalPlumbingCivilGeneral
Roof2p · 1 filing · 10 docs
Floor 37p · 1 filing · 20 docs
Floor 29p · 2 filings · 20 docs
Floor 18p · 1 filing · 20 docs
Cellar1p · 1 filing · 10 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
UNITED DEVELOPERS2007/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/18/2024$983K—— → —$399/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PIROOZ ENGINEERING, P.C.706/30/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J&J DESIGNS INCGeneral Contractor507/08/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PIROOZ ENGINEERING P.C7177406/30/2024
IP CONCRETE TESTING AND I6252206/27/2024
Building Lifecycle
All (81)Filed (7)Permit Issued (4)Signed Off (3)Inspection (9)Objection (28)Special Inspection (30)
08/26/2024
Signed off — Alteration
Installation of Plumbing fixtures and related piping in conjunction with New Building JOB # Q00904434
Q00904550-I1
08/16/2024
Signed off — Alteration
PROPOSED 12' CURB CUT IN CONJUNCTION WITH NB APPLICATION # Q00904434
Q00904361-I1
08/12/2024
Signed off — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE IN CONJUNCTION WITH NB APPLICATION # Q00904434
Q00904405-I1
08/02/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/02/2024
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
07/25/2024
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
07/22/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/17/2024
Permit issued — Curb Cut
Q00904361-I1-CC
07/11/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
PIROOZ SOLTANIZADEH
07/11/2024
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
INDARDEO PARBHUNATH
07/11/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
PIROOZ SOLTANIZADEH
07/11/2024
Special inspection requirement — Energy Code Compliance Inspections
PIROOZ SOLTANIZADEH
06/30/2024
Filed — New Building
PROPOSED 3-STORY BUILDING ( 2 STORY FRAME OVER 1 STORY CONCRETE), TWO FAMILY.
Q00904434-P1
06/27/2024
Filed — Alteration
Installation of Plumbing fixtures and related piping in conjunction with New Building JOB # Q00904434
Q00904550-P1
06/27/2024
Objection resolved — Addressed
06/27/2024
Special inspection requirement — Heating Systems
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Masonry
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Mechanical Systems
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Structural Cold-Formed Steel
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Structural Steel - Details
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Subgrade Inspections
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
INDARDEO PARBHUNATH
06/27/2024
Special inspection requirement — Energy Code Compliance Inspections
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Final
JAN PEREZ
06/27/2024
Special inspection requirement — Fire-Resistance Rated Construction
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Footing and Foundation
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Lowest Floor Elevation
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Preliminary
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Structural Wood Frame
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Fenestration air leakage
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Maintenance information
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — HVAC-R and service water heating system controls
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Air barrier — testing
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Fenestration areas
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — HVAC-R and service water heating equipment
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Metering
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Air barrier - visual inspection
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Interior lighting power
PIROOZ SOLTANIZADEH
06/27/2024
Special inspection requirement — Duct leakage testing, insulation and design
PIROOZ SOLTANIZADEH
06/24/2024
Objection raised — Scope
06/11/2024
Filed — Alteration
PROPOSED 12' CURB CUT IN CONJUNCTION WITH NB APPLICATION # Q00904434
Q00904361-P1
03/18/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/18/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
03/18/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/18/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/18/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/22/2024
Permit issued — Plumbing
Q00904550-I1-PL
01/26/2024
Permit issued — Construction Fence
Q00904405-I1-FN
01/26/2024
Permit issued — Structural
Q00904434-I1-GC-CX
12/29/2023
Objection resolved — Addressed
12/28/2023
Objection resolved — Addressed
12/18/2023
Objection resolved — Addressed
09/26/2023
Objection raised — Fire_Protection
09/26/2023
Objection raised — Mechanical
09/26/2023
Objection resolved — Addressed
09/19/2023
Objection resolved — Addressed
09/19/2023
Objection resolved — Addressed
09/19/2023
Objection resolved — Addressed
Latest 60 of 81 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offJ&J DESIGNS INC07/17/2024
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR02/22/2024
DOB NOWConstruction FenceSigned-offJ&J DESIGNS INC01/26/2024
DOB NOWStructuralPermit IssuedJ&J DESIGNS INC01/26/2024
1 project · most recent 06/30/2024
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/30/2024Permit IssuedJ&J DESIGNS INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Lg LT0816CER 8,000 BTU · Ptac ×12
LT1216CER 12,000 BTU · Ptac ×4
Heating
Navien NCB-190/060H 60,000 BTU · Boiler ×4
Ventilation
Panasonic FV-05VQ5 50 CFM · Exhaust Fan ×8
FV-15VQ5 150 BTU · Exhaust Fan ×4
1 project · most recent 07/21/2024
General Wiring
FiledStatusContractorScope
07/21/2024CompleteSKY ELECTRIC LLCGeneral Wiring
1 project · most recent 06/30/2024
Steel Concrete Wood
FiledStatusContractorScope
06/30/2024Permit IssuedJ&J DESIGNS INCSteel, Concrete, Wood
1 project · most recent 06/30/2024
Earthwork
FiledStatusContractorScope
06/30/2024Permit IssuedJ&J DESIGNS INCEarthwork
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
08/02/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/02/2024Pass-Final Curb Cut Non-Directive 14PassView ↗
07/25/2024Fail-Final Curb Cut Non-Directive 14FailView ↗
07/22/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/18/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/18/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
03/18/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/18/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/18/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 42
DateRequirementInspectorRole
07/11/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationPIROOZ SOLTANIZADEHspecial
07/11/2024Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesINDARDEO PARBHUNATHspecial
07/11/2024Fire-Resistant Penetrations and JointsPIROOZ SOLTANIZADEHspecial
07/11/2024Energy Code Compliance InspectionsPIROOZ SOLTANIZADEHprogress
06/27/2024Heating SystemsPIROOZ SOLTANIZADEHspecial
06/27/2024MasonryPIROOZ SOLTANIZADEHspecial
06/27/2024Mechanical SystemsPIROOZ SOLTANIZADEHspecial
06/27/2024Structural Cold-Formed SteelPIROOZ SOLTANIZADEHspecial
06/27/2024Structural Steel - DetailsPIROOZ SOLTANIZADEHspecial
06/27/2024Subgrade InspectionsPIROOZ SOLTANIZADEHspecial
06/27/2024Subsurface Investigations (Borings/Test Pits)INDARDEO PARBHUNATHspecial
06/27/2024Energy Code Compliance InspectionsPIROOZ SOLTANIZADEHprogress
06/27/2024FinalJAN PEREZprogress
06/27/2024Fire-Resistance Rated ConstructionPIROOZ SOLTANIZADEHprogress
06/27/2024Footing and FoundationPIROOZ SOLTANIZADEHprogress
06/27/2024Lowest Floor ElevationPIROOZ SOLTANIZADEHprogress
06/27/2024PreliminaryPIROOZ SOLTANIZADEHprogress
06/27/2024Structural Wood FramePIROOZ SOLTANIZADEHprogress
06/27/2024Fenestration air leakagePIROOZ SOLTANIZADEHenergy_progress
06/27/2024Fenestration and door U-factor and product ratingsPIROOZ SOLTANIZADEHenergy_progress
06/27/2024Maintenance informationPIROOZ SOLTANIZADEHenergy_progress
06/27/2024HVAC-R and service water heating system controlsPIROOZ SOLTANIZADEHenergy_progress
06/27/2024Air barrier — testing PIROOZ SOLTANIZADEHenergy_progress
06/27/2024Fenestration areasPIROOZ SOLTANIZADEHenergy_progress
06/27/2024HVAC-R and service water heating equipmentPIROOZ SOLTANIZADEHenergy_progress
Latest 25 of 42.
▾Documents — 76 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/24/2026Q00904405-I1Request digital key ↗
08/22/2026Q00904361-I1Request digital key ↗
08/22/2026Q00904550-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION2
05/22/2024440800545Open ↗
08/30/2023440800545Open ↗
▸BISDOT 410 PERMITS FOR ADA RAMPS1
09/10/2024440800545Open ↗
▸BISBPP-DOT: SIDEWALK/CURB/ROAD WORK PERMITS1
09/10/2024440800545Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
06/12/2024440800545Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/22/2026Q00904434-I1Open ↗
08/13/2026Q00904434-P1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/22/2026Q00904434-I1Open ↗
08/13/2026Q00904434-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00904434-I1Open ↗
▸Seals & Professional Certifications21
▸DOB NOWSpecial Inspector Seal & Signature7
09/27/2026Q00904550-I1Open ↗
09/27/2026Q00904550-I1Open ↗
08/26/2026Q00904434-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/24/2026Q00904405-I1Open ↗
08/22/2026Q00904434-I1Open ↗
08/13/2026Q00904361-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/27/2026Q00904550-I1Open ↗
08/26/2026Q00904434-P1Open ↗
08/26/2026Q00904434-P1Open ↗
Showing 3 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
08/30/2023440800545Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/30/2023440800545Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/22/2026Q00904434-I1Open ↗
08/13/2026Q00904434-P1Open ↗
▸Safety & Tenant Protection9
▸DOB NOWStreet Tree Checklist2
08/22/2026Q00904434-I1Open ↗
08/13/2026Q00904434-P1Open ↗
▸BISSTREET TREES SITE PLAN1
09/09/2024440800545Open ↗
▸BISBPP: STREET TREES SITE PLAN1
06/12/2024440800545Open ↗
▸BISSTREET TREE CHECKLIST1
09/22/2023440800545Open ↗
▸BISSTREET TREE SIGNOFF1
09/09/2024440800545Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00904434-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026Q00904434-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00904434-I1Open ↗
▸Energy Compliance1
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q00904434-I1Open ↗
▸Inspections & Test Reports5
▸DOB NOWSOIL REPORT2
08/22/2026Q00904434-I1Open ↗
08/13/2026Q00904434-P1Open ↗
▸BISBPP: SIDEWALK CONCRETE STRENGTH REPORT1
09/10/2024440800545Open ↗
▸BISBPP: FIELD INSPECTION1
09/10/2024440800545Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00904434-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
09/10/2024440800545Open ↗
▸BISCURB CUT (CC) SIGNOFF1
09/09/2024440800545Open ↗
▸BISDOT APPROVAL FOR APEX CORNER PEDRAMPS1
06/12/2024440800545Open ↗
▸Cost, Insurance & Ownership1
▸BISBPP: ENGINEERS AFFIDAVIT1
09/10/2024440800545Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
08/30/2023440800545Open ↗
▸Other Documents16
▸DOB NOWSite Survey: Initial2
08/22/2026Q00904434-I1Open ↗
08/13/2026Q00904434-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/22/2026Q00904434-I1Open ↗
08/13/2026Q00904434-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/22/2026Q00904434-I1Open ↗
08/13/2026Q00904434-P1Open ↗
▸BISBPP: TOPOGRAPHIC SURVEY1
09/22/2023440800545Open ↗
▸BISBPP-PARKS: PLANT NEW TREE1
09/10/2024440800545Open ↗
▸BISBPP: FINAL AS-BUILT PHOTOGRAPHS1
09/10/2024440800545Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
09/22/2023440800545Open ↗
▸BISBPP: AS-BUILT SIDEWALK SURVEY1
09/10/2024440800545Open ↗
▸BISDOT COMPLIANCES FOR ADA RAMPS AT CORNERS1
09/10/2024440800545Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
09/16/2024440800545Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00904434-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00904434-I1Open ↗
▸DOB NOWFEMA Elevation Certificate (086-0-33)/Flood Proofing Certificate (086-0-34)1
08/13/2026Q00904434-I1Open ↗