← Back
Three families
69-14 FRESH MEADOW LANE
QUEENS · Pomonok-Electchester-Hillcrest · BIN 4150235
💬 Discuss this project
1950Year Built
2Stories
C0Building Class
R4Zoning
2,646 sfGross Floor Area
3Units
1 Open Violation ▸FDNY Report ↗
Three families · 2,244 sf lot · 1.18 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Filed — no permit issued6p · 2 filings · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/07/2023$1.2M—— → —$448/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LI ARCHITECT ASSOCIATE, PLLC202/28/2023
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LI ARCHITECT ASSOCIATE, P1104112/09/2022
Building Lifecycle
All (18)Filed (2)Violation (1)Objection (4)Special Inspection (11)
02/28/2023
Filed — Alteration CO
Q00836526-I1
02/28/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/28/2023
Special inspection requirement — Energy Code Compliance Inspections
02/28/2023
Special inspection requirement — Fire-Resistance Rated Construction
02/28/2023
Special inspection requirement — Fenestration areas
02/28/2023
Special inspection requirement — Insulation placement and R values
02/28/2023
Special inspection requirement — Interior lighting power
02/28/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
02/28/2023
Special inspection requirement — Maintenance information
02/28/2023
Special inspection requirement — Air barrier - visual inspection
02/28/2023
Special inspection requirement — Fenestration air leakage
01/10/2023
Objection resolved — Addressed
12/16/2022
Objection raised — Plumbing
12/16/2022
Objection raised — Scope
12/16/2022
Objection resolved — Addressed
12/09/2022
Filed — Alteration
INSTALL NEW GAS BOILER AND NEW GAS H.W.H,SEPARATE GAS UTILITY FOR 1ST & 2ND FL DWELLING.NO CHANGE IN USE, EGRESS, AND OCCUPANCY
Q08051465-I1
12/07/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ling Li
01/08/1990
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Nothing on file for this building.
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
02/28/2023Fire-Resistant Penetrations and Joints—special
02/28/2023Energy Code Compliance Inspections—progress
02/28/2023Fire-Resistance Rated Construction—progress
02/28/2023Fenestration areas—energy_progress
02/28/2023Insulation placement and R values—energy_progress
02/28/2023Interior lighting power—energy_progress
02/28/2023Fenestration and door U-factor and product ratings—energy_progress
02/28/2023Maintenance information—energy_progress
02/28/2023Air barrier - visual inspection—energy_progress
02/28/2023Fenestration air leakage—energy_progress
12/07/2022Fire-Resistant Penetrations and JointsLing Lispecial
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026Q08051465-I1Request digital key ↗
08/25/2026Q00836526-I1Request digital key ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026Q08051465-I1Open ↗
08/25/2026Q00836526-I1Open ↗
▸Other Documents2
▸DOB NOWFinal Survey1
08/13/2026Q00836526-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/25/2026Q00836526-I1Open ↗