| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 11/08/2022 | $960K | — | PROPER BOOKKEEPING INC. → A9Z | $482/sf building |
| 01/21/2022 | $820K | — | Private party → PROPER BOOKKEEPING INC | $412/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| NY Building Associates | 1 | 03/26/2024 |
| AA Building & Inspection Service | 8 | 02/20/2024 |
| KNF Services Crop | 1 | 05/27/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| Dmconsulting6860 | 16 | 03/21/2026 |
| KNF Services Crop | 1 | 03/21/2026 |
| S R Solar Design | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Gim Construction | General Contractor | 4 | 03/21/2026 |
| Amber Electrical Contracting | General Contractor | 3 | 03/21/2026 |
| FRSS Group | Scaffold | 2 | 03/21/2026 |
| All Pro Plumbing & Heating | Plumbing | 2 | 07/08/2026 |
| G.M.A. Plumbing & Heating | Plumbing | 1 | 07/08/2026 |
| FRSS Group | General Contractor | 1 | 07/08/2026 |
| Great Tim Construction | Scaffold | 1 | 07/08/2026 |
| Joseph Weinstein Electric | Electrical | 1 | 03/22/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| NKM Engineering | 6244 | 1 | 03/26/2024 |
| HRF Services | 5616 | 8 | 02/20/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Solar | Signed-off | Amber Electrical Contracting | 12/04/2024 |
| DOB NOW | Plumbing | Signed-off | All Pro Plumbing & Heating | 01/03/2024 |
| DOB NOW | Construction Fence | Signed-off | FRSS Group | 02/03/2023 |
| DOB NOW | Plumbing | Signed-off | All Pro Plumbing & Heating | 12/07/2022 |
| DOB NOW | Mechanical Systems | Permit Issued | FRSS Group | 12/05/2022 |
| DOB NOW | Plumbing | Signed-off | G.M.A. Plumbing & Heating | 06/27/2022 |
| DOB NOW | Foundation | Permit Issued | Richter + Ratner Builders | 06/10/2022 |
| DOB NOW | Mechanical Systems | Permit Issued | Richter + Ratner Builders | 04/12/2022 |
| DOB NOW | Construction Fence | Signed-off | Great Tim Construction | 03/15/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 02/20/2024 | Permit Issued | FRSS Group | Air Conditioning Systems, Heating Systems | Cooling Mitsubishi Electric M4H36W06060615-B 400,000 BTU ×10 Heating Mitsubishi Electric M4H36W06060615-B 40,000 BTU ×10 Ventilation Mitsubishi Electric M4H36W06060615-B 40,000 BTU ×10 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/20/2024 | Signed-off | All Pro Plumbing & Heating | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/25/2024 | Complete | Amber Electl Contng | — |
| 12/15/2023 | Complete | Joseph Weinstein Electric | General Wiring |
| 07/05/2022 | Cancelled | Lens Electric | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/20/2024 | Signed-off | All Pro Plumbing & Heating | Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 01/24/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 01/17/2024 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 12/05/2023 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/17/2023 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 03/17/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/17/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 03/21/2024 | Air barrier - visual inspection | NARESH MAHANGU | energy_progress |
| 03/21/2024 | Final | NARESH MAHANGU | progress |
| 03/21/2024 | Energy Code Compliance Inspections | NARESH MAHANGU | progress |
| 03/21/2024 | Structural Stability – Alterations of existing buildings | NARESH MAHANGU | special |
| 03/21/2024 | Fire-Resistant Penetrations and Joints | NARESH MAHANGU | special |
| 02/23/2024 | Heating Systems | FAHAD FATEH | special |
| 02/23/2024 | High-Pressure Fuel-Gas Piping (Welding) | FAHAD FATEH | special |
| 02/23/2024 | Concrete - Cast-In-Place | FAHAD FATEH | special |
| 02/23/2024 | Structural Stability – Alterations of existing buildings | FAHAD FATEH | special |
| 02/23/2024 | Structural Wood Frame | FAHAD FATEH | progress |
| 02/23/2024 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 02/23/2024 | Final | FAHAD FATEH | progress |
| 02/23/2024 | Fire-Resistance Rated Construction | FAHAD FATEH | progress |
| 02/23/2024 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 02/23/2024 | Interior lighting power | FAHAD FATEH | energy_progress |
| 02/23/2024 | Exterior lighting power | FAHAD FATEH | energy_progress |
| 02/23/2024 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 02/23/2024 | Mechanical Systems | FAHAD FATEH | special |
| 02/23/2024 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 02/23/2024 | Maintenance information | FAHAD FATEH | energy_progress |
| 02/23/2024 | HVAC-R and service water piping design and insulation | FAHAD FATEH | energy_progress |
| 02/23/2024 | Protection of exposed foundation insulation | FAHAD FATEH | energy_progress |
| 02/23/2024 | HVAC-R and service water heating equipment | FAHAD FATEH | energy_progress |
| 02/23/2024 | Duct leakage testing, insulation and design | FAHAD FATEH | energy_progress |
| 02/23/2024 | HVAC-R and service water heating system controls | FAHAD FATEH | energy_progress |