Locations of Work
ArchitectureStructuralPlumbing
Roof1p · 1 filing · 14 docs
Floor 21p · 1 filing · 14 docs
Floor 12p · 1 filing · 14 docs
Cellar1p · 1 filing · 14 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/05/2021$1.4M—Private party → Private party$624/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TL ARCHITECT, PLLC303/25/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HTX BUILDING CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
XH&RC PLBG AND HTG INCPlumbing207/08/2026
JYNY CONSTRUCTION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CITISCAPE CONSULTING LTD762203/25/2023
Building Lifecycle
All (22)Filed (3)Permit Issued (3)Signed Off (2)Inspection (5)Special Inspection (9)
07/23/2024
Signed off — Alteration
Propose plumbing work.
Q00690312-S1
07/23/2024
Signed off — Alteration
Propose plumbing work.
Q00690312-I1
03/07/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/05/2024
Permit issued — Plumbing
Q00690312-S1-PL
04/03/2023
Special inspection requirement — Fire-Resistance Rated Construction
Timothy Lee
04/03/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Joe Lieberman
04/03/2023
Special inspection requirement — Energy Code Compliance Inspections
Timothy Lee
04/03/2023
Special inspection requirement — Final
Timothy Lee
03/25/2023
Filed — Alteration
Propose plumbing work.
Q00690312-P1
03/20/2023
Special inspection requirement — Fire-Resistance Rated Construction
Timothy Lee
03/20/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Joe Lieberman
03/20/2023
Special inspection requirement — Energy Code Compliance Inspections
Timothy Lee
03/20/2023
Special inspection requirement — Final
Timothy Lee
01/17/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/17/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/12/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/22/2022
Permit issued — Plumbing
Q00690312-S1-PL
09/15/2022
Filed — Alteration
Propose plumbing work.
Q00690312-S1
09/14/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Timothy Lee
08/18/2022
Permit issued — General Construction
Q00690312-I1-GC
03/11/2022
Filed — Alteration
Propose plumbing work.
Q00690312-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offXH&RC PLBG AND HTG INC03/05/2024
DOB NOWPlumbingSigned-offXH&RC PLBG AND HTG INC10/22/2022
DOB NOWGeneral ConstructionSigned-offJYNY CONSTRUCTION08/18/2022
1 project · most recent 03/26/2024
General Wiring
FiledStatusContractorScope
03/26/2024CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
03/07/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/17/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/17/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/17/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/12/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
04/03/2023Fire-Resistance Rated ConstructionTimothy Leeprogress
04/03/2023Fire-Resistant Penetrations and JointsJoe Liebermanspecial
04/03/2023Energy Code Compliance InspectionsTimothy Leeprogress
04/03/2023FinalTimothy Leeprogress
03/20/2023Fire-Resistance Rated ConstructionTimothy Leeprogress
03/20/2023Fire-Resistant Penetrations and JointsJoe Liebermanspecial
03/20/2023Energy Code Compliance InspectionsTimothy Leeprogress
03/20/2023FinalTimothy Leeprogress
09/14/2022HVAC-R and service water piping design and insulationTimothy Leeenergy_progress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/26/2026Q00690312-P1Request digital key ↗
08/26/2026Q00690312-S1Request digital key ↗
08/26/2026Q00690312-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/26/2026Q00690312-P1Open ↗
08/26/2026Q00690312-S1Open ↗
08/26/2026Q00690312-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/27/2026Q00690312-S1Open ↗
08/26/2026Q00690312-P1Open ↗
08/23/2026Q00690312-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026Q00690312-P1Open ↗
08/23/2026Q00690312-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/26/2026Q00690312-P1Open ↗
08/26/2026Q00690312-S1Open ↗
08/26/2026Q00690312-I1Open ↗