← Back
One story - permanent living quarter
69-26 171 STREET
QUEENS · Fresh Meadows-Utopia · BIN 4150027
💬 Discuss this project
1950Year Built
1Stories
A2Building Class
R2Zoning
1,372 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
One story - permanent living quarter · 4,085 sf lot · 0.34 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalGeneral
Roof1 filing · 4 docs
Floor 11p · 1 filing · 6 docs
Cellar1p · 1 filing · 6 docs
Site & exterior2p · 1 filing · 6 docs
Filed — no permit issued5p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Fabrikant of America Development407/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/10/2023$1.1M—— → —$802/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HAYM S. GROSS, ARCHITECT209/10/2024
M-CON ENGINEERING, PC109/05/2024
AMINOV DESIGN ENGINEER, PC111/04/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BRITZ ENTERPRISES INC.403/21/2026
A D BUILDING SOLUTIONS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUSTAINABLE STRATEGIESGeneral Contractor203/21/2026
ASCUATECH ELECTRICAL CORPElectrical103/22/2026
FABRIKANT OF AMERICA DEVGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M-CON ENGINEERING7341109/05/2024
Building Lifecycle
All (27)Filed (4)Permit Issued (2)Signed Off (1)Violation (1)Inspection (2)Special Inspection (17)
07/13/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
06/30/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/15/2024
Signed off — Alteration
Q01105197-I1
09/13/2024
Permit issued — Solar
Q01105197-I1-SL
09/10/2024
Filed — Alteration
ENLARGE FRONT AND REAR CONCRETE PORCHES
Q01057741-P1
09/05/2024
Filed — Alteration
Q01105197-I1
06/14/2024
Permit issued — General Construction
Q01057741-I1-GC
06/07/2024
Filed — Alteration
ENLARGE FRONT AND REAR CONCRETE PORCHES
Q01057741-I1
05/06/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/05/2023
Special inspection requirement — Interior lighting power
11/05/2023
Special inspection requirement — Permanent certificate
11/05/2023
Special inspection requirement — Ventilation and air distribution system
11/05/2023
Special inspection requirement — Fire-Resistance Rated Construction
11/05/2023
Special inspection requirement — Maintenance information
11/04/2023
Filed — Alteration
APPLICATION FILED FOR INTERIOR RENOVATION TO AN EXISTING ONE FAMILY DWELLING. NO CHANGE IN BULK, USE OR EGRESS IS PROPOSED.
Q00953712-I1
10/26/2023
Special inspection requirement — Mechanical Systems
10/26/2023
Special inspection requirement — HVAC-R and service water heating system controls
10/26/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
10/26/2023
Special inspection requirement — Electric vehicle service equipment requirements
10/26/2023
Special inspection requirement — Air barrier - visual inspection
10/26/2023
Special inspection requirement — Fenestration areas
10/26/2023
Special inspection requirement — Insulation placement and R values
10/26/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
10/26/2023
Special inspection requirement — Final
10/26/2023
Special inspection requirement — Energy Code Compliance Inspections
10/26/2023
Special inspection requirement — Fenestration air leakage
10/26/2023
Special inspection requirement — HVAC-R and service water heating equipment
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUSTAINABLE STRATEGIES09/13/2024
DOB NOWGeneral ConstructionPermit IssuedFABRIKANT OF AMERICA DEV06/14/2024
1 project · most recent 11/04/2023
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
11/04/2023——Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-8c48NA 48,000 BTU · Heat Pump Outdoor ×2
3 projects · most recent 09/01/2024
General Wiring
FiledStatusContractorScope
09/01/2024Permit IssuedASCUATECH ELECTRICAL CORP—
08/25/2024CompleteSOURCE ELECTRIC INC1 meters
05/16/2024Permit IssuedKINGS ELECTRIC CO., INC.General Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
07/13/2026Fail-Final General Construction Non-Directive 14FailView ↗
06/30/2026Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
11/05/2023Interior lighting power—energy_progress
11/05/2023Permanent certificate—energy_progress
11/05/2023Ventilation and air distribution system—energy_progress
11/05/2023Fire-Resistance Rated Construction—progress
11/05/2023Maintenance information—energy_progress
10/26/2023Mechanical Systems—special
10/26/2023HVAC-R and service water heating system controls—energy_progress
10/26/2023HVAC-R and service water piping design and insulation—energy_progress
10/26/2023Electric vehicle service equipment requirements—energy_progress
10/26/2023Air barrier - visual inspection—energy_progress
10/26/2023Fenestration areas—energy_progress
10/26/2023Insulation placement and R values—energy_progress
10/26/2023Fenestration and door U-factor and product ratings—energy_progress
10/26/2023Final—progress
10/26/2023Energy Code Compliance Inspections—progress
10/26/2023Fenestration air leakage—energy_progress
10/26/2023HVAC-R and service water heating equipment—energy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/23/2026Q00953712-I1Request digital key ↗
08/21/2026Q01105197-I1Request digital key ↗
08/21/2026Q01057741-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/23/2026Q00953712-I1Open ↗
08/21/2026Q01105197-I1Open ↗
08/21/2026Q01057741-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/23/2026Q00953712-I1Open ↗
08/21/2026Q01105197-I1Open ↗
08/21/2026Q01057741-I1Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01105197-I1Open ↗