← Back
Condo, commercial tower (mixed-use) [derived]
69-30 AUSTIN STREET
QUEENS · BIN 4077468
💬 Discuss this project
1988Year Built
4Stories
RCBuilding Class
R5DZoning
45,713 sfGross Floor Area
10Units
LL97 Covered1 Open Violation ▸
Condo, commercial tower (mixed-use) [derived] · Owner of record: UNAVAILABLE OWNER · 15,380 sf lot · 2.97 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionEquipmentCivilGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction13p · 7 filings · 20 docs
Floor 4Under Construction13p · 3 filings · 20 docs
Floor 3Under Construction13p · 4 filings · 20 docs
Floor 2Under Construction13p · 5 filings · 20 docs
Floor 1Under Construction13p · 7 filings · 20 docs
CellarUnder Construction1p · 1 filing · 4 docs
3 jobs · most recent 07/13/2026
Heating and Air Conditioning Systems Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/13/2026Permit IssuedTITAN BUILDERS & CONSTRAir Conditioning Systems, Heating and Air Conditioning Systems
Cooling
Lg KUSAB181A 18,000 BTU · Heat Pump Outdoor ×2
Daikin FAQ18TAVJUA 18,000 BTU · Vrf Indoor ×2
Heat / Cool
Lg 505KCGW2LU63 37,000 BTU · Heat Pump Outdoor ×1
ARUM072BTE5 73,000 BTU · Vrf Outdoor ×1
ARUN096BSS6 103,000 BTU · Vrf Outdoor ×1
ZRUM048GSS0 49,500 BTU · Vrf Outdoor ×1
Trane YSK150A3SBH 202,500 BTU · Rooftop Unit ×2
Captiveaire CAS-HVAC3-I.400-20-20T-DOAS 280,000 BTU · Makeup Air ×1
Daikin RXTQ48TAVJUA 49,500 BTU · Vrf Outdoor ×3
RXTQ36TAVJ9A 34,200 BTU · Vrf Outdoor ×1
RXYQ96XATJA 92,000 BTU · Vrf Outdoor ×1
Carrier 48LCRA12A2M5-4R2CO 10 tons · Rooftop Unit ×2
62X718-GMTCAG4-BN 238,300 BTU · Condensing Unit ×1
07/17/2025Signed-offSPK/LEWIS CONSTRUCTION LLHeating and Air Conditioning Systems
Heat / Cool
Lg ARUN024GSS4 27,000 BTU · Vrf Outdoor ×2
Trane YSK150A3SBH 248,000 BTU · Rooftop Unit ×2
04/12/2024Signed-offTITAN BUILDERS & CONSTRVentilation Systems
Ventilation
Greenheck SQ-70-VG 150 CFM · Exhaust Fan ×1
6 jobs · most recent 07/13/2026
Sprinkler System
FiledStatusContractorScope
07/13/2026Signed-offARCO PLBG AND HTG INCSprinkler System
09/30/2025Signed-offARCO PLBG AND HTG INC66 heads
07/17/2025Signed-offARCO PLBG AND HTG INCSprinkler System
04/12/2024Signed-offARCO PLBG AND HTG INC—
11/09/2022Signed-offARCO PLBG AND HTG INC—
06/01/2022Signed-offBROOK PLUMBING & HTG CORP—
4 jobs · most recent 07/13/2026
Water/Sanitary Gas Storm
FiledStatusContractorScope
07/13/2026Signed-offPIPE SOLUTIONS ADVIS INCGas, Storm, Water/Sanitary
07/17/2025Signed-offPIPE SOLUTIONS ADVIS INCGas, Water/Sanitary
04/12/2024Signed-offPIPE SOLUTIONS ADVIS INCWater/Sanitary
11/09/2022Permit IssuedPIPE SOLUTIONS ADVIS INCWater/Sanitary
8 jobs · most recent 11/03/2025
General Wiring
FiledStatusContractorScope
11/03/2025Permit IssuedA.S.K. ELECTRICAL CORPGeneral Wiring
09/18/2025Permit IssuedWATTS A MATTA ELEC LLCGeneral Wiring
05/16/2025Permit IssuedQUEENSBORO ELEC'L CONTR'G—
03/29/2025CompleteNASH ELECTRIC SERVICES IN—
03/14/2023Permit IssuedHIRSCHEL ELECTRICAL INC.General Wiring
01/17/2023Permit IssuedVILLAGE ELECTL CONTRS INCGeneral Wiring
12/08/2022CompleteHIGH QUALITY ELECTRIC OF—
12/13/2019Permit IssuedLIPPOLIS ELECTRIC, INC.General Wiring
1 job · most recent 07/13/2026
Steel Concrete Masonry
FiledStatusContractorScope
07/13/2026Permit IssuedTITAN BUILDERS & CONSTRSteel, Concrete, Masonry
Building Lifecycle
All (296)Filed (38)Permit Issued (58)Signed Off (27)Violation (60)Inspection (44)Objection (39)Special Inspection (30)
09/02/2026
Permit issued — Structural
Q08008613-S4-ST
08/24/2026
Objection resolved — Resolved
08/21/2026
Objection raised — Scope
08/04/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/29/2026
Signed off — Alteration CO
Installation of new HVAC as shown on plans filed herewith.
Q08008613-S3
07/16/2026
Signed off — Alteration
MECHANICAL WORK ASSOCIATED WITH INTERIOR RENOVATION AT 4TH FL AS PER PLANS FILED HEREWITH
Q01198796-S2
07/16/2026
Signed off — Alteration
Modifications to existing sprinkler system on 1st floor for tenant fit-out as per plans filed.
Q08033059-I1
07/16/2026
Signed off — Alteration
PLUMBING AND SPRINKLER SCOPE ASSOCIATED WITH OFFICE FIT OUT AS PER PLANS FILED HEREWITH.
Q00990912-S2
07/16/2026
Signed off — Alteration CO
Installation of new HVAC as shown on plans filed herewith.
Q08008613-S5
07/16/2026
Signed off — Alteration
Modifications to existing sprinkler system on floors 1 and 2 for tenant fit-out as per plans filed.
Q08006302-I1
07/13/2026
Filed — Alteration CO
Installation of new HVAC as shown on plans filed herewith.
Q08008613-P1
06/23/2026
Permit issued — Sprinklers
Q00745833-I1-EW-SP
06/22/2026
Signed off — Alteration
Plumbing work on 1st floor in conjunction with tenant fit-out.
Q08033045-I1
06/04/2026
Signed off — Alteration CO
Installation of new HVAC as shown on plans filed herewith.
Q08008613-S6
05/29/2026
Signed off — Alteration
PLUMBING AND SPRINKLER SCOPE ASSOCIATED WITH OFFICE FIT OUT AS PER PLANS FILED HEREWITH.
Q00990912-S1
05/29/2026
Signed off — Alteration
Q00745805-I1
05/27/2026
Signed off — Alteration
Mechanical modifications and installations in conjunction partial 1st and 2nd floor tenant fit-out.
Q08006281-I1
05/27/2026
Signed off — Alteration
MECHANICAL WORK ASSOCIATED WITH INTERIOR RENOVATION AT 4TH FL AS PER PLANS FILED HEREWITH
Q01198796-S1
05/27/2026
Signed off — Alteration
Mechanical modifications and installations in conjunction with tenant fit-out on 1st floor and roof.
Q08033052-I1
05/20/2026
Signed off — Alteration
MECHANICAL WORK ASSOCIATED WITH INTERIOR RENOVATION AT 4TH FL AS PER PLANS FILED HEREWITH
Q01198796-I1
05/15/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/13/2026
Signed off — Alteration
Q08006319-I1
05/13/2026
Signed off — Alteration
Install two bathrooms on 1st floor.
Q00745816-I1
05/06/2026
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
05/06/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/05/2026
Permit issued — Mechanical Systems
Q08033052-I1-MS
05/01/2026
Signed off — Alteration
Plumbing modifications and installations in conjunction with tenant fit-out per plans filed.
Q08006291-I1
05/01/2026
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
04/29/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/27/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/24/2026
Signed off — Alteration
Interior partitions on 1st floor.
Q00745734-I1
04/24/2026
Signed off — Alteration
Interior buildout on first floor. Change use from retail Use Group 6A to health and fitness establishment Use Group 6A which is permitted as per BB 2009-025.
Q08033264-I1
04/24/2026
Signed off — Alteration
PLUMBING AND SPRINKLER SCOPE ASSOCIATED WITH OFFICE FIT OUT AS PER PLANS FILED HEREWITH.
Q00990912-I1
04/24/2026
Signed off — Alteration CO
Installation of new HVAC as shown on plans filed herewith.
Q08008613-S1
04/24/2026
Permit issued — Sprinklers
Q08006302-I1-EW-SP
04/23/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
04/22/2026
Permit issued — Sprinklers
Q08033059-I1-EW-SP
04/22/2026
Permit issued — Standpipe
Q08008613-S5-EW-SD
04/22/2026
Permit issued — Plumbing
Q00990912-S2-EW-SP
04/22/2026
Permit issued — Sprinklers
Q01198796-S2-EW-SP
04/22/2026
Permit issued — Sprinklers
Q08008613-S3-EW-SP
04/21/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/20/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/15/2026
Permit issued — Mechanical Systems
Q08008613-S6-MS
04/15/2026
Objection resolved — Resolved
04/14/2026
Filed — Alteration CO
Installation of new HVAC as shown on plans filed herewith.
Q08008613-S6
04/14/2026
Permit issued — Plumbing
Q08006291-I1-PL
04/03/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/02/2026
Permit issued — Plumbing
Q00745816-I1-PL
04/02/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/27/2026
Permit issued — General Construction
Q08008613-I1-GC
03/27/2026
Special inspection requirement — HVAC-R and service water heating system controls
SHAHRIAR QUAYYUM
03/27/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
03/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SHAHRIAR QUAYYUM
03/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/27/2026
Special inspection requirement — Final
SHAHRIAR QUAYYUM
03/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
SHAHRIAR QUAYYUM
03/27/2026
Special inspection requirement — Maintenance information
Latest 60 of 296 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
69-40 AUSTIN STREET PARTNER LLC REC2509/03/2026
TRAVE8607/08/2026
JEM CONTRACTING507/08/2026
ARGONAUT HOLDING103/22/2026
OWNER OF PREMISES103/22/2026
TO THE OWNER OF103/22/2026
69-40 AUSTIN STREET103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.5403/21/2026
GEIGER E A GROUP803/21/2026
HIERARCH-E203/21/2026
ADVANCED BUILDERS SERVICES103/21/2026
ARCHI PRO GROUP103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRAVE LLCGeneral Contractor3207/08/2026
DYNAMIX SCAFFOLD GROUP LLGeneral Contractor807/08/2026
PIPE SOLUTIONS ADVIS INCPlumbing707/08/2026
TITAN BUILDERS & CONSTRGeneral Contractor609/03/2026
ARCO PLBG AND HTG INCFire Protection607/08/2026
SPK/LEWIS CONSTRUCTION LLGeneral Contractor407/08/2026
MC SUPERSTRUCTURE INCGeneral Contractor404/09/2026
TITAN REALTY & CONSTRUCTIGeneral Contractor307/08/2026
FLINT MECHANICAL CORPFire Protection306/27/2026
SUPERIOR SERVICES DEMO INGeneral Contractor303/21/2026
P & D MECHANICAL CORPFire Protection207/08/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
WATTS A MATTA ELEC LLCElectrical103/22/2026
BROOK PLUMBING & HTG CORPFire Protection106/27/2026
PRIME PIPING & HEATING INFire Protection106/28/2026
JEM CONTRACTING CORPGeneral Contractor107/08/2026
BROOK PLUMBING & HTG CORPPlumbing107/08/2026
NASH ELECTRIC SERVICES INElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP56162507/13/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedTITAN BUILDERS & CONSTR09/02/2026
DOB NOWSprinklersSigned-offBROOK PLUMBING & HTG CORP06/23/2026
DOB NOWMechanical SystemsSigned-offTITAN BUILDERS & CONSTR05/05/2026
DOB NOWSprinklersSigned-offARCO PLBG AND HTG INC04/24/2026
DOB NOWSprinklersSigned-offARCO PLBG AND HTG INC04/22/2026
DOB NOWStandpipeSigned-offARCO PLBG AND HTG INC04/22/2026
DOB NOWPlumbingSigned-offARCO PLBG AND HTG INC04/22/2026
DOB NOWSprinklersSigned-offARCO PLBG AND HTG INC04/22/2026
DOB NOWSprinklersSigned-offARCO PLBG AND HTG INC04/22/2026
DOB NOWMechanical SystemsSigned-offTITAN REALTY & CONSTRUCTI04/15/2026
DOB NOWPlumbingSigned-offPIPE SOLUTIONS ADVIS INC04/14/2026
DOB NOWPlumbingSigned-offBROOK PLUMBING & HTG CORP04/02/2026
DOB NOWGeneral ConstructionPermit IssuedTITAN REALTY & CONSTRUCTI03/27/2026
DOB NOWProtection and Mechanical MethodsSigned-offMC SUPERSTRUCTURE INC03/20/2026
DOB NOWSprinklersSigned-offP & D MECHANICAL CORP02/10/2026
DOB NOWSprinklersSigned-offP & D MECHANICAL CORP02/09/2026
DOB NOWMechanical SystemsSigned-offTITAN BUILDERS & CONSTR01/07/2026
DOB NOWMechanical SystemsSigned-offSPK/LEWIS CONSTRUCTION LL11/24/2025
DOB NOWGeneral ConstructionSigned-offSPK/LEWIS CONSTRUCTION LL11/24/2025
DOB NOWPlumbingSigned-offPIPE SOLUTIONS ADVIS INC10/30/2025
DOB NOWPlumbingSigned-offPIPE SOLUTIONS ADVIS INC10/27/2025
DOB NOWPlumbingSigned-offPIPE SOLUTIONS ADVIS INC10/24/2025
DOB NOWPlumbingSigned-offBLETSAS P&H CORP10/21/2025
DOB NOWPlumbingSigned-offBLETSAS P&H CORP10/21/2025
DOB NOWSprinklersSigned-offBLETSAS P&H CORP10/20/2025
DOB NOWPlumbingPermit IssuedPIPE SOLUTIONS ADVIS INC09/18/2025
DOB NOWGeneral ConstructionSigned-offSPK/LEWIS CONSTRUCTION LL09/15/2025
DOB NOWMechanical SystemsSigned-offSPK/LEWIS CONSTRUCTION LL09/15/2025
DOB NOWGeneral ConstructionSigned-offTITAN BUILDERS & CONSTR07/17/2025
DOB NOWGeneral ConstructionSigned-offTITAN BUILDERS & CONSTR07/17/2025
DOB NOWGeneral ConstructionSigned-offTITAN BUILDERS & CONSTR07/17/2025
DOB NOWPlumbingSigned-offPIPE SOLUTIONS ADVIS INC05/14/2025
DOB NOWSupported ScaffoldSigned-offMC SUPERSTRUCTURE INC04/18/2025
DOB NOWSidewalk ShedSigned-offMC SUPERSTRUCTURE INC03/27/2025
DOB NOWGeneral ConstructionPermit IssuedTITAN REALTY & CONSTRUCTI03/27/2025
DOB NOWGeneral ConstructionSigned-offTRAVE LLC05/23/2024
DOB NOWMechanical SystemsSigned-offTRAVE LLC05/23/2024
DOB NOWPlumbingSigned-offPIPE SOLUTIONS ADVIS INC03/22/2024
DOB NOWSidewalk ShedSigned-offDYNAMIX SCAFFOLD GROUP LL12/15/2023
DOB NOWConstruction FenceSigned-offDYNAMIX SCAFFOLD GROUP LL12/13/2023
+ 16 more permits on file
▾Field Inspections (DOB CAP) — 44
DateTypeResultReport
08/04/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/15/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/06/2026Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
05/06/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/01/2026Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
04/29/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/27/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/23/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/21/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/20/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/03/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/02/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/30/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/23/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/09/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
02/24/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
02/23/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/11/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/04/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
02/04/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/02/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/09/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/16/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/12/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
Latest 25 of 44.
▾Special Inspection Requirements (DOB NOW) — 75
DateRequirementInspectorRole
03/27/2026HVAC-R and service water heating system controls—energy_progress
03/27/2026Maintenance information—energy_progress
03/27/2026HVAC-R and service water piping design and insulation—energy_progress
03/27/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
03/27/2026Shutoff dampersSHAHRIAR QUAYYUMenergy_progress
03/27/2026HVAC-R and service water heating equipment—energy_progress
03/27/2026HVAC-R and service water heating system controlsSHAHRIAR QUAYYUMenergy_progress
03/27/2026HVAC-R and service water heating equipmentSHAHRIAR QUAYYUMenergy_progress
03/27/2026HVAC-R and service water piping design and insulationSHAHRIAR QUAYYUMenergy_progress
03/27/2026FinalSHAHRIAR QUAYYUMprogress
03/27/2026Mechanical SystemsSHAHRIAR QUAYYUMspecial
03/27/2026Shutoff dampers—energy_progress
03/25/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
10/07/2025Energy Code Compliance InspectionsFAHAD FATEHprogress
10/07/2025FinalFAHAD FATEHprogress
10/07/2025HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
10/07/2025HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
10/07/2025HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
10/07/2025Mechanical SystemsFAHAD FATEHspecial
10/03/2025Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
10/01/2025Sprinkler SystemsFAHAD FATEHspecial
10/01/2025Standpipe SystemsFAHAD FATEHspecial
09/30/2025HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
09/30/2025HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
09/30/2025FinalFAHAD FATEHprogress
Latest 25 of 75.
▾Documents — 187 on file (BIS + DOB NOW)
▸Plans & Drawings39
▸DOB NOWPlans/Sketch39
08/27/2026Q00602897-I1Request digital key ↗
08/26/2026Q00745734-I1Request digital key ↗
08/26/2026Q00745805-I1Request digital key ↗
Showing 3 of 39 on file for this type
▸Applications & Permits7
▸BISPLAN / WORK APPROVAL APPLICATION5
03/28/2018421602242Open ↗
03/13/2018421602242Open ↗
02/20/2018421602242Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION2
02/23/2018421602242Open ↗
08/19/2015421202077Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026Q08008613-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026Q08008613-I1Open ↗
▸Seals & Professional Certifications87
▸DOB NOWDPL-1: Design Professional Seal & Signature39
08/26/2026Q00745734-I1Open ↗
08/26/2026Q00745805-I1Open ↗
08/26/2026Q00745816-I1Open ↗
Showing 3 of 39 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature21
09/23/2026Q01198796-S1Open ↗
09/05/2026Q01198796-S2Open ↗
09/02/2026Q00990912-S2Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWProgress Inspector Seal & Signature20
09/23/2026Q01198796-S1Open ↗
09/23/2026Q01198796-S1Open ↗
09/01/2026Q08006281-P2Open ↗
Showing 3 of 20 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
01/10/2019421602242Open ↗
02/20/2018421602242Open ↗
08/17/2015421202077Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
02/20/2018421602242Open ↗
08/17/2015421202077Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
02/20/2018421602242Open ↗
08/17/2015421202077Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
03/28/2018421602242Open ↗
03/13/2018421602242Open ↗
02/20/2018421602242Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
02/20/2018421602242Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q08008613-I1Open ↗
▸Environmental & Asbestos26
▸DOB NOWDEP ACP-5: Asbestos Assessment Report17
08/26/2026Q00745734-I1Open ↗
08/26/2026Q00745805-I1Open ↗
08/26/2026Q00745816-P1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form7
08/17/2026Q08008613-S2Open ↗
08/17/2026Q08008613-S3Open ↗
08/17/2026Q08008613-S6Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
08/17/2015421202077Open ↗
11/18/2013420921998Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
01/10/2019421602242Open ↗
02/20/2018421602242Open ↗
08/17/2015421202077Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
01/10/2019421602242Open ↗
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
01/10/2019421602242Open ↗
09/01/2016420921998Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
09/01/2016420921998Open ↗
07/19/2016421202077Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
11/18/2013420921998Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
01/10/2019421602242Open ↗
02/20/2018421602242Open ↗
09/01/2016420921998Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
02/20/2018421602242Open ↗
08/17/2015421202077Open ↗
11/18/2013420921998Open ↗
▸BISBOROUGH INTAKE FORM1
03/28/2018421602242Open ↗
▸Other Documents2
▸DOB NOWProperty Ownership Certification1
08/17/2026Q08008613-I1Open ↗
▸DOB NOWFinal Survey1
08/17/2026Q08008613-I1Open ↗