← Back
Three families
69 HYLAN BOULEVARD
STATEN ISLAND · Rosebank-Shore Acres-Park Hill · BIN 5042162
💬 Discuss this project
1899Year Built
2Stories
C0Building Class
R4Zoning
1,436 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Three families · 3,500 sf lot · 0.41 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof4p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RESIDENCE103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC204/07/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNCO CAPITAL LLCGeneral Contractor203/21/2026
FOLINO, PETERElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854204/07/2025
Building Lifecycle
All (23)Filed (2)Permit Issued (1)Violation (6)Objection (2)Special Inspection (12)
04/14/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
04/14/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
04/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
04/14/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
04/14/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
04/14/2025
Special inspection requirement — Final
TOM PETERSEN
04/07/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
S01179255-P1
04/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
04/07/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
04/07/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
04/07/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
04/07/2025
Special inspection requirement — Final
TOM PETERSEN
04/07/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
03/25/2025
Permit issued — Solar
S01179255-I1-SL
03/07/2025
Objection resolved — Addressed
02/27/2025
Objection raised — Other
02/18/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
S01179255-I1
04/22/2021
Violation issued (HPD, closed)
I
11/08/2019
Violation issued (HPD, closed)
I
09/04/2019
Violation issued (ECB, closed)
Construction
01/10/2018
Violation issued (HPD, closed)
I
10/25/2003
Violation issued (ECB, closed)
Construction
10/20/2003
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSUNCO CAPITAL LLC03/25/2025
BISOTISSUEDM. JORDAN GENERAL CONTRACTING07/12/2017
BISPLISSUEDABLE PLBG CO RICHMOND INC07/12/2017
4 projects · most recent 03/04/2025
General Wiring
FiledStatusContractorScope
03/04/2025CompleteBERGER QUALITY ELEC'L CON3 meters
02/20/2025CompleteBERGER QUALITY ELEC'L CON—
04/24/2020CompleteJOSEPH WEINSTEIN ELECTRIC2 meters
09/23/2019CompleteJOSEPH WEINSTEIN ELECTRICGeneral Wiring
1 project · most recent 04/07/2025
FiledStatusContractorScope
04/07/2025Permit IssuedSUNCO CAPITAL LLC28 panels, 11.76 kw, 890 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
04/14/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
04/14/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
04/14/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
04/14/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
04/14/2025Energy Code Compliance InspectionsTOM PETERSENprogress
04/14/2025FinalTOM PETERSENprogress
04/07/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
04/07/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
04/07/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
04/07/2025Energy Code Compliance InspectionsTOM PETERSENprogress
04/07/2025FinalTOM PETERSENprogress
04/07/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/19/2026S01179255-I1Request digital key ↗
08/19/2026S01179255-P1Request digital key ↗
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
08/01/2017520278262Open ↗
08/01/2017520278262Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
06/27/2017520278262Open ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026S01179255-P1Open ↗
09/01/2026S01179255-P1Open ↗
08/25/2026S01179255-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026S01179255-P1Open ↗
09/01/2026S01179255-P1Open ↗
08/25/2026S01179255-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026S01179255-I1Open ↗
08/13/2026S01179255-P1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/27/2017520278262Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/27/2017520278262Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
06/27/2017520278262Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026S01179255-I1Open ↗
08/13/2026S01179255-P1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
08/31/2017520278262Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
06/27/2017520278262Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
08/31/2017520278262Open ↗
06/27/2017520278262Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
06/27/2017520278262Open ↗
▸BISBOROUGH INTAKE FORM1
08/31/2017520278262Open ↗