← Back
Two family brick
69 MONROE STREET
BROOKLYN · BIN 3057045
💬 Discuss this project
1899Year Built
2Stories
B1Building Class
R6AZoning
2,415 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two family brick · 1,575 sf lot · 1.53 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
Floor 3Under Construction5p · 2 filings · 9 docs
Floor 2Under Construction5p · 2 filings · 9 docs
Floor 1Under Construction5p · 2 filings · 9 docs
CellarUnder Construction7p · 2 filings · 9 docs
Sub-BasementUnder Construction5p · 2 filings · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ELITE PROPERTIES NYC308/29/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PRIME ZONE BUILDING CONSULTING206/26/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
XINLI.CONSTRUCTION LLCGeneral Contractor107/02/2026
PRIME PIPING & HEATING INPlumbing107/02/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PRIME ZONE BUILDING CONSU9474206/26/2026
NKM ENGINEERING PLLC6244105/26/2026
Building Lifecycle
All (10)Filed (2)Permit Issued (2)Violation (1)Special Inspection (5)
06/30/2026
Permit issued — Mechanical Systems
B01406709-I1-GC-CX
06/30/2026
Permit issued — Plumbing
B01422658-I1-PL
06/26/2026
Filed — Alteration
PLUMBING WORK IN EXISTING 3 STORY WITH BASEMENT & CELLAR,2 FAMILY BUILDING, AS PER PLANS IN CONJUNCTION WITHALT 2 APPLICATION B01406709.NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION.
B01422658-I1
06/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
JICHEN SUN
06/26/2026
Special inspection requirement — Energy Code Compliance Inspections
JICHEN SUN
06/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
JICHEN SUN
06/26/2026
Special inspection requirement — HVAC-R and service water heating system controls
JICHEN SUN
06/26/2026
Special inspection requirement — HVAC-R and service water heating equipment
JICHEN SUN
05/26/2026
Filed — Alteration
INTERIOR RENOVATION IN EXISTING (3) THREE STORY WITH BASEMENT AND CELLAR, (2) TWO-FAMILY BUILDING WITH MECHANICAL WORK. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY IN THIS APPLICATION.
B01406709-I1
12/04/2024
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedXINLI.CONSTRUCTION LLC06/30/2026
DOB NOWPlumbingPermit IssuedPRIME PIPING & HEATING IN06/30/2026
1 project · most recent 05/26/2026
Air Conditioning Systems Heating Systems
FiledStatusContractorScope
05/26/2026Permit IssuedXINLI.CONSTRUCTION LLCAir Conditioning Systems, Heating Systems
1 project · most recent 06/26/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/26/2026Permit IssuedA M B MECHANICAL INCGas, Water/Sanitary
1 project · most recent 06/03/2026
General Wiring
FiledStatusContractorScope
06/03/2026Permit IssuedAPPROVED ELECTRIC CORP.General Wiring
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
06/26/2026Fire-Resistant Penetrations and JointsJICHEN SUNspecial
06/26/2026Energy Code Compliance InspectionsJICHEN SUNprogress
06/26/2026HVAC-R and service water piping design and insulationJICHEN SUNenergy_progress
06/26/2026HVAC-R and service water heating system controlsJICHEN SUNenergy_progress
06/26/2026HVAC-R and service water heating equipmentJICHEN SUNenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/16/2026B01406709-I1Request digital key ↗
08/16/2026B01422658-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/16/2026B01406709-I1Open ↗
08/16/2026B01422658-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026B01422658-I1Open ↗
08/24/2026B01422658-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026B01422658-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/16/2026B01406709-I1Open ↗
08/16/2026B01422658-I1Open ↗