← Back
Two family frame
692 DELAFIELD AVENUE
STATEN ISLAND · BIN 5006084
💬 Discuss this project
1899Year Built
2.5Stories
B2Building Class
R3AZoning
2,688 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 9,050 sf lot · 0.3 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 10 docs
Floor 11p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RESIDENCE103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PATRICIA L. GASS603/21/2026
DESIGN CONCEPTS203/21/2026
SANARK CONSULTING ENGINEERING D P C203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KCM PLUMBING & HEATING COPlumbing507/08/2026
2D CONSTRUCTION CORPGeneral Contractor203/21/2026
AQUATECH MECH,PLBG & ELECElectrical103/22/2026
MAXIMUM CONTRACTING INCGeneral Contractor107/08/2026
V & M DRAIN CLEANING INCPlumbing107/08/2026
Building Lifecycle
All (32)Filed (6)Permit Issued (8)Signed Off (3)Violation (3)Inspection (2)Objection (5)Special Inspection (5)
08/07/2026
Objection raised — Scope
09/24/2025
Filed — New Building
HEREWITH, FILING FOR THE CONSTRUCTION OF TWO ACCESORY BUILDINGS GREATER THAN 120 S.F. EACH, NO CHANGE TO EX. USE, EGRESS, OCCUPANCY, PARKING, ENERGY EFFICIENCY, ACCESSIBILITY, OR FIRE RESISTANCE RATINGS FROM THE RESIDENTIAL BLG. IS PROPOSED UNDER THIS APP
S01252510-I1
09/23/2025
Special inspection requirement — Concrete - Cast-In-Place
REJEP KOLAR
09/23/2025
Special inspection requirement — Subgrade Inspections
REJEP KOLAR
09/23/2025
Special inspection requirement — Energy Code Compliance Inspections
REJEP KOLAR
09/23/2025
Special inspection requirement — Fire-Resistance Rated Construction
REJEP KOLAR
09/23/2025
Special inspection requirement — Interior lighting power
REJEP KOLAR
10/30/2024
Signed off — Alteration
S00844910-I1
10/30/2024
Signed off — Alteration
Single story addition to an existing 2 family dwelling
S00841962-I1
06/24/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/19/2024
Permit issued — General Construction
S00841962-I1-GC
03/13/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/07/2024
Permit issued — Plumbing
S00844910-I1-PL
03/01/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/24/2023
Permit issued — Plumbing
S00844910-I1-PL
10/09/2023
Filed — Alteration
S00844910-I1
09/25/2023
Permit issued — General Construction
S00841962-I1-GC
08/21/2023
Objection resolved — Addressed
08/07/2023
Objection resolved — Addressed
08/01/2023
Objection raised — Structural
07/17/2023
Objection raised — Scope
06/29/2023
Filed — Alteration
Single story addition to an existing 2 family dwelling
S00841962-I1
08/09/2022
Signed off — Alteration
APPLICATION FILED IN CONJUNCTION WITH ALTERATION TYPE 2 APPLICATION TO INSTALL (1) GAS PIPE FOR BBQ AND (1) STANDPIPE FOR RESIDENTIAL SINK AT REAR OF RESIDENCE.
S00376312-I1
06/18/2022
Permit issued — Plumbing
S57750013-I1-PL
02/16/2022
Filed — Alteration
APPLICATION FILED IN CONJUNCTION WITH ALTERATION TYPE 2 APPLICATION TO INSTALL (1) GAS PIPE FOR BBQ AND (1) STANDPIPE FOR RESIDENTIAL SINK AT REAR OF RESIDENCE.
S00376312-P2
06/28/2021
Permit issued — Plumbing
S57750013-I1-PL
09/23/2020
Filed — Alteration
APPLICATION FILED IN CONJUNCTION WITH ALTERATION TYPE 2 APPLICATION TO INSTALL (1) GAS PIPE FOR BBQ AND (1) STANDPIPE FOR RESIDENTIAL SINK AT REAR OF RESIDENCE.
S00376312-P1
07/29/2020
Permit issued — Plumbing
S57750013-I1-PL
07/27/2020
Filed — Alteration
APPLICATION FILED IN CONJUNCTION WITH ALTERATION TYPE 2 APPLICATION TO INSTALL (1) GAS PIPE FOR BBQ AND (1) STANDPIPE FOR RESIDENTIAL SINK AT REAR OF RESIDENCE.
S00376312-I1
07/27/2020
Permit issued — Plumbing
S00376312-I1-PL
05/11/1992
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
02/21/1992
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-off2D CONSTRUCTION CORP03/19/2024
DOB NOWPlumbingSigned-offV & M DRAIN CLEANING INC03/07/2024
DOB NOWPlumbingSigned-offKCM PLUMBING & HEATING CO10/24/2023
DOB NOWGeneral ConstructionSigned-offMAXIMUM CONTRACTING INC09/25/2023
DOB NOWPlumbingSigned-offKCM PLUMBING & HEATING CO06/18/2022
DOB NOWPlumbingSigned-offKCM PLUMBING & HEATING CO06/28/2021
DOB NOWPlumbingSigned-offKCM PLUMBING & HEATING CO07/29/2020
DOB NOWPlumbingSigned-offKCM PLUMBING & HEATING CO07/27/2020
BISOTISSUEDKCM PLMBG & HTNG CORP08/17/2020
2 projects · most recent 12/12/2023
General Wiring
FiledStatusContractorScope
12/12/2023CompleteM & M CONTROL WIRING &General Wiring
05/03/2022CompleteAQUATECH MECH,PLBG & ELEC2 meters
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
06/24/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/13/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
09/23/2025Concrete - Cast-In-PlaceREJEP KOLARspecial
09/23/2025Subgrade InspectionsREJEP KOLARspecial
09/23/2025Energy Code Compliance InspectionsREJEP KOLARprogress
09/23/2025Fire-Resistance Rated ConstructionREJEP KOLARprogress
09/23/2025Interior lighting powerREJEP KOLARenergy_progress
▾Documents — 39 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch - Plumbing3
08/26/2026S00376312-P2Request digital key ↗
08/26/2026S00376312-I1Request digital key ↗
08/15/2026S00376312-P1Request digital key ↗
▸DOB NOWPlans/Sketch3
08/23/2026S00841962-I1Request digital key ↗
08/22/2026S00844910-I1Request digital key ↗
08/14/2026S01252510-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
08/14/2020540181435Open ↗
▸BISWORK PERMIT APPLICATION1
08/17/2020540181435Open ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026S01252510-I1Open ↗
08/13/2026S00841962-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/14/2026S01252510-I1Open ↗
08/13/2026S01252510-I1Open ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/23/2026S00841962-I1Open ↗
08/22/2026S00844910-I1Open ↗
08/18/2026S01252510-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026S01252510-I1Open ↗
08/23/2026S01252510-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
08/14/2020540181435Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/14/2020540181435Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/14/2020540181435Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026S01252510-I1Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026S01252510-I1Open ↗
08/13/2026S00841962-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/23/2026S00841962-I1Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
08/14/2020540181435Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
03/11/2021540181435Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
03/11/2021540181435Open ↗
08/14/2020540181435Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/11/2021540181435Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
03/11/2021540181435Open ↗
08/14/2020540181435Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
08/14/2020540181435Open ↗
▸Other Documents4
▸DOB NOWSite Survey: Initial2
08/13/2026S01252510-I1Open ↗
08/13/2026S00841962-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026S00841962-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026S00841962-I1Open ↗