← Back
BuildNYC
Two stories - detached, small or mid-size
7-31 LEGGETT PLACE
QUEENS · BIN 4102772
💬 Discuss this project
1950Year Built
2Stories
A1Building Class
R2AZoning
1,997 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,800 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
PlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 24p · 2 filings · 20 docs
Floor 14p · 2 filings · 20 docs
Cellar4p · 4 filings · 20 docs
Site & exteriorProposed fence construction1p · 1 filing · 3 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/20/2013$600K—Private party → Private party$300/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CD Architect Studio307/23/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CD Architect Studio603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Apollo Plumbing & HeatingPlumbing507/08/2026
Abanno WaterproofingScaffold407/08/2026
Pro Tech RenovationsGeneral Contractor106/24/2020
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CD Architect Studio2573207/23/2020
Building Lifecycle
08/19/2024
Signed off — Alteration
Remove and cap kitchen equipment and shower at 1st floor, new Navien combination boiler at cellar, new kitchen and fireplace at 1st floor and (3) new bathrooms at 2nd floor
Q00358239-S1
08/19/2024
Signed off — Alteration
Remove and cap kitchen equipment and shower at 1st floor, new Navien combination boiler at cellar, new kitchen and fireplace at 1st floor and (3) new bathrooms at 2nd floor
Q00358239-I1
07/23/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/18/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/15/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
37 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offApollo Plumbing & Heating07/02/2024
DOB NOWPlumbingSigned-offApollo Plumbing & Heating07/02/2024
DOB NOWConstruction FenceSigned-offAbanno Waterproofing09/14/2021
DOB NOWConstruction FenceSigned-offAbanno Waterproofing10/07/2020
DOB NOWPlumbingSigned-offApollo Plumbing & Heating07/31/2020
DOB NOWPlumbingSigned-offApollo Plumbing & Heating07/23/2020
DOB NOWPlumbingSigned-offApollo Plumbing & Heating07/23/2020
DOB NOWConstruction FenceSigned-offAbanno Waterproofing06/09/2020
BIS—ISSUEDPro Tech Renovations06/24/2020
1 project · most recent 08/24/2020
General Wiring
FiledStatusContractorScope
08/24/2020CompleteNew York City ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
07/23/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/18/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/15/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
07/09/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/09/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
07/09/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
07/23/2020HVAC insulation and sealing Nat Costanzaenergy_progress
07/23/2020Fire-Resistant Penetrations and JointsNat Costanzaspecial
07/23/2020Energy Code Compliance InspectionsNat Costanzaprogress
07/23/2020Fire-Resistance Rated ConstructionNat Costanzaprogress
07/23/2020Maintenance informationNat Costanzaenergy_progress
07/23/2020HVAC and service water heating equipment Nat Costanzaenergy_progress
07/23/2020Electrical energy consumptionNat Costanzaenergy_progress
07/23/2020HVAC and service water heating system controls Nat Costanzaenergy_progress
07/16/2020Maintenance informationNat Costanzaenergy_progress
07/16/2020HVAC and service water heating equipment Nat Costanzaenergy_progress
07/16/2020HVAC and service water heating system controls Nat Costanzaenergy_progress
07/16/2020HVAC insulation and sealing Nat Costanzaenergy_progress
06/15/2020Electrical energy consumptionNat Costanzaenergy_progress
06/15/2020Fire-Resistance Rated ConstructionNat Costanzaprogress
06/15/2020Energy Code Compliance InspectionsNat Costanzaprogress
06/15/2020Fire-Resistant Penetrations and JointsNat Costanzaspecial
06/05/2020FinalNat Costanzaprogress
83 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account