← Back
Miscellaneous two family
7 CLIFFORD PLACE
BROOKLYN · BIN 3065262
💬 Discuss this project
1920Year Built
2Stories
B9Building Class
R6BZoning
2,260 sfGross Floor Area
2Units
Miscellaneous two family · 2,275 sf lot · 0.99 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction21p · 1 filing · 20 docs
Floor 3Under Construction25p · 1 filing · 20 docs
Floor 2Under Construction21p · 1 filing · 20 docs
Floor 1Under Construction21p · 1 filing · 20 docs
CellarUnder Construction25p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/26/2024$2.6M—— → —$1,173/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JEFFREY BEANE ENGINEERING, PLLC103/31/2026
ATELIERTEK ARCHITECTS210/06/2025
WELLS ENGINEERING, PLLC205/30/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EUROSTRUCT INCGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASE ENGINEERING PLLC5785403/31/2026
Building Lifecycle
All (34)Filed (5)Permit Issued (2)Inspection (5)Objection (22)
08/03/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/29/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/17/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/17/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/15/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/04/2026
Permit issued — Construction Fence
B01218398-S4-FN
04/27/2026
Permit issued — General Construction
B01218398-I1-GC
04/10/2026
Objection resolved — Addressed
03/31/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed 236.58 linear feet of construction fence. Street frontage is 25 feet
B01218398-S1
10/06/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed 236.58 linear feet of construction fence. Street frontage is 25 feet
B01218398-S4
09/22/2025
Objection resolved — Addressed
09/11/2025
Objection resolved — Resolved
09/11/2025
Objection resolved — Resolved
08/21/2025
Objection resolved — Addressed
07/31/2025
Objection resolved — Addressed
07/31/2025
Objection resolved — Addressed
06/16/2025
Objection raised — Plumbing
06/16/2025
Objection raised — Energy
05/30/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed 236.58 linear feet of construction fence. Street frontage is 25 feet
B01218398-S3
05/30/2025
Objection raised — Plumbing
05/30/2025
Objection raised — Plumbing
05/30/2025
Objection raised — Energy
05/30/2025
Objection raised — Admin
05/30/2025
Objection resolved — Addressed
05/30/2025
Objection resolved — Addressed
05/29/2025
Objection raised — Scope
05/29/2025
Objection raised — Scope
05/29/2025
Objection raised — Admin
05/29/2025
Objection raised — Zoning
05/29/2025
Objection raised — Fire_Protection
05/29/2025
Objection raised — Scope
05/29/2025
Objection raised — Zoning
05/22/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed 236.58 linear feet of construction fence. Street frontage is 25 feet
B01218398-S2
05/15/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
Proposed 236.58 linear feet of construction fence. Street frontage is 25 feet
B01218398-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedEUROSTRUCT INC05/04/2026
DOB NOWGeneral ConstructionPermit IssuedEUROSTRUCT INC04/27/2026
1 project · most recent 03/31/2026
Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/31/2026Permit IssuedEUROSTRUCT INCHeating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM60NL 66,000 BTU · Condensing Unit ×2
Heating
Electro Industries EDB-T1-36-208-3 123,000 BTU · Boiler ×2
Ventilation
Mitsubishi Electric PEFY-L15NMAU-A 15,000 BTU · Vrf Indoor ×4
PKFY-L15NLMU-A 15,000 BTU · Vrf Indoor ×1
PVFY-L30NAMU-A 30,000 BTU · Vrf Indoor ×1
PVFY-L36NAMU-A 36,000 BTU · Vrf Indoor ×1
Panasonic FV-0511VQC1 150 CFM · Exhaust Fan ×4
FV-15VE1S 150 CFM · Erv ×1
1 project · most recent 03/31/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
03/31/2026——Gas, Storm, Water/Sanitary
1 project · most recent 03/31/2026
Steel Concrete Wood
FiledStatusContractorScope
03/31/2026Permit IssuedEUROSTRUCT INCSteel, Concrete, Wood
1 project · most recent 03/31/2026
Fence
FiledStatusContractorScope
03/31/2026Permit IssuedEUROSTRUCT INCFence
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/03/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/29/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/17/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/17/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/15/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
06/01/2026HVAC-R and service water heating system controls—energy_progress
06/01/2026Permanent certificate—energy_progress
06/01/2026Maintenance information—energy_progress
06/01/2026HVAC-R and service water piping design and insulation—energy_progress
06/01/2026HVAC-R and service water heating equipment—energy_progress
05/22/2025Fire-Resistant Penetrations and Jointsalon egozispecial
05/22/2025Energy Code Compliance Inspectionsalon egoziprogress
05/15/2025Protection of exposed foundation insulationalon egozienergy_progress
05/15/2025Fire-Resistant Penetrations and Jointsalon egozispecial
05/15/2025Energy Code Compliance Inspectionsalon egoziprogress
05/15/2025Fire-Resistance Rated Constructionalon egoziprogress
05/06/2025Air barrier - visual inspectionalon egozienergy_progress
05/06/2025Permanent certificatealon egozienergy_progress
05/06/2025Fenestration air leakagealon egozienergy_progress
05/06/2025Fenestration and door U-factor and product ratingsalon egozienergy_progress
05/06/2025Fenestration areasalon egozienergy_progress
05/06/2025Insulation placement and R valuesalon egozienergy_progress
05/06/2025Air barrier — testing alon egozienergy_progress
▾Documents — 36 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/17/2026B01218398-S3Request digital key ↗
08/17/2026B01218398-S2Request digital key ↗
08/17/2026B01218398-S1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
06/30/2009320044938Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026B01218398-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/17/2026B01218398-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/17/2026B01218398-I1Open ↗
08/17/2026B01218398-S4Open ↗
08/17/2026B01218398-S3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/24/2026B01218398-I1Open ↗
08/24/2026B01218398-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
06/30/2009320044938Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026B01218398-I1Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING1
06/30/2009320044938Open ↗
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/17/2026B01218398-I1Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
06/30/2009320044938Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
08/17/2026B01218398-S2Open ↗
08/17/2026B01218398-I1Open ↗
08/17/2026B01218398-S3Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
06/30/2009320044938Open ↗
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/17/2026B01218398-S1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
06/30/2009320044938Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
06/30/2009320044938Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
06/30/2009320044938Open ↗
▸BISEFILING COVER SHEET1
06/30/2009320044938Open ↗
▸Other Documents7
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/17/2026B01218398-I1Open ↗
08/17/2026B01218398-S1Open ↗
▸DOB NOWSite Survey: Initial2
08/17/2026B01218398-S1Open ↗
08/17/2026B01218398-I1Open ↗
▸BISPLOT DIAGRAM1
06/30/2009320044938Open ↗
▸DOB NOWAdjoining Owners Notification1
08/17/2026B01218398-S1Open ↗
▸DOB NOWProperty Ownership Certification1
08/17/2026B01218398-I1Open ↗