← Back
Miscellaneous indoor public assembly
7 SKILLMAN STREET
BROOKLYN · BIN 3334680
💬 Discuss this project
1960Year Built
1Stories
P9Building Class
M1-2/R6AZoning
25,794 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Miscellaneous indoor public assembly · Owner of record: BEDFORD FLUSHING HOLDING CORP. · 23,715 sf lot · 1.09 FAR built · Flood zone X
Locations of Work
Architecture
Roof3p · 1 filing · 15 docs
Floor 12p · 1 filing · 15 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BEDFORD FLUSHING HOLDING CORP.903/21/2026
CONCORD PLAZA103/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ADVANCED BUILDERS SERVICES603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GREEN LIGHT ELECL & MECHElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
REGIONAL TESTING CORP.394206/10/2022
Building Lifecycle
All (58)Filed (6)Violation (12)Objection (10)Special Inspection (30)
11/03/2022
Violation issued (FDNY_ORDER, closed)
11/03/2022
Violation issued (FDNY_ORDER, closed)
11/03/2022
Violation issued (FDNY_ORDER, closed)
11/03/2022
Violation issued (FDNY_ORDER, closed)
11/03/2022
Violation issued (FDNY_ORDER, closed)
11/03/2022
Violation issued (FDNY_NOV, closed)
11/03/2022
Violation issued (FDNY_ORDER, closed)
06/10/2022
Filed — Alteration
Foundation application filed for one footing only; filed in conjunction with NB, job number: B00724881-I1.
B00742527-P2
06/10/2022
Special inspection requirement — Deep Foundation Elements
Paul Raymond
06/10/2022
Special inspection requirement — Final
Paul Raymond
06/10/2022
Special inspection requirement — Footing and Foundation
Paul Raymond
06/10/2022
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
Paul Raymond
06/10/2022
Special inspection requirement — Concrete - Cast-In-Place
Paul Raymond
06/10/2022
Special inspection requirement — Subgrade Inspections
Paul Raymond
06/10/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
GEORGE CAMBOURAKIS
06/09/2022
Objection resolved — Resolved
06/08/2022
Objection resolved — Resolved
06/08/2022
Objection resolved — Resolved
06/08/2022
Objection resolved — Resolved
06/02/2022
Filed — Alteration
8'-0" High Temporary Construction Fence in conjunction New Building #B
B00748568-I1
06/02/2022
Objection raised — Energy
06/02/2022
Objection raised — Admin
06/02/2022
Objection raised — Scope
06/01/2022
Objection resolved — Resolved
05/27/2022
Objection raised — Other
05/27/2022
Objection raised — Energy
05/25/2022
Filed — Alteration
Foundation application filed for one footing only; filed in conjunction with NB, job number: B00724881-I1.
B00742527-P1
05/24/2022
Special inspection requirement — Concrete - Cast-In-Place
05/24/2022
Special inspection requirement — Deep Foundation Elements
05/24/2022
Special inspection requirement — Subgrade Inspections
05/24/2022
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
05/24/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
GEORGE CAMBOURAKIS
05/24/2022
Special inspection requirement — Final
05/24/2022
Special inspection requirement — Footing and Foundation
05/23/2022
Filed — Alteration
Foundation application filed for one footing only; filed in conjunction with NB, job number: B00724881-I1.
B00742527-I1
05/23/2022
Filed — New Building
B00724881-S1
05/23/2022
Special inspection requirement — Deep Foundation Elements
05/23/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
05/17/2022
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
05/17/2022
Special inspection requirement — Concrete - Cast-In-Place
05/17/2022
Special inspection requirement — Insulation placement and R values
05/17/2022
Special inspection requirement — Final
05/17/2022
Special inspection requirement — Footing and Foundation
05/17/2022
Special inspection requirement — Protection of exposed foundation insulation
05/17/2022
Special inspection requirement — Subgrade Inspections
05/13/2022
Filed — New Building
B00724881-I1
05/02/2022
Special inspection requirement — Lighting in dwelling units
05/02/2022
Special inspection requirement — Exterior lighting power
05/02/2022
Special inspection requirement — Metering
05/02/2022
Special inspection requirement — Protection of exposed foundation insulation
05/02/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
05/02/2022
Special inspection requirement — Permanent certificate
05/02/2022
Special inspection requirement — Vestibules
07/29/2021
Violation issued (FDNY_NOV, closed)
05/25/2018
Violation issued (FDNY_NOV, closed)
03/26/2018
Violation issued (FDNY_NOV, closed)
01/11/2017
Violation issued (FDNY_NOV, closed)
08/18/2016
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISPLISSUEDPRIME PIPING & HEATING IN07/19/2018
BISFPISSUEDALLIED FIRE CONTROL SVCS11/21/2017
BISPLISSUEDSAFETY PLMBG & HTG LLC11/22/2016
BISFPISSUEDALLIED FIRE CONTROL SVCS11/01/2016
BISPLISSUEDS. WACHTEL PLBG & HTG INC02/26/2016
BISOTISSUEDM. INT'L ENGINEERING PLLC11/24/2015
BISPLISSUEDPREMIER SEWER & WATERMAIN LLC,06/18/2014
BISSPISSUEDPREMIER SEWER & WATERMAIN06/17/2014
BISSPISSUEDH.A.M. FIRE EQUIPMENT INC12/05/2013
BISPLISSUEDJTP PLBING CONTRACTOR, LT08/08/2013
BISMHISSUEDBEDFORD FLUSHING HOL;DING CORP03/25/2005
BISPLISSUEDNYC WATER MAIN WORKS INC.01/02/2004
BISPLISSUEDKAMAR MECHANICAL PLBG & HTG INC11/13/2002
BIS—ISSUEDBEDFORD FLUSHING HOLDING02/18/1998
BISSPISSUEDCAPITOL FIRE SPKL CO,INC12/14/1995
1 project · most recent 05/16/2019
FiledStatusContractorScope
05/16/2019CompleteGREEN LIGHT ELECL & MECH—
1 project · most recent 06/10/2022
FiledStatusContractorScope
06/10/2022——4 scope_items
1 project · most recent 06/02/2022
Fence
FiledStatusContractorScope
06/02/2022——Fence
▾Special Inspection Requirements (DOB NOW) — 47
DateRequirementInspectorRole
06/10/2022Deep Foundation ElementsPaul Raymondspecial
06/10/2022FinalPaul Raymondprogress
06/10/2022Footing and FoundationPaul Raymondprogress
06/10/2022Subsurface Conditions – Fill Placement & In-Place DensityPaul Raymondspecial
06/10/2022Concrete - Cast-In-PlacePaul Raymondspecial
06/10/2022Subgrade InspectionsPaul Raymondspecial
06/10/2022Subsurface Investigations (Borings/Test Pits)GEORGE CAMBOURAKISspecial
05/24/2022Concrete - Cast-In-Place—special
05/24/2022Deep Foundation Elements—special
05/24/2022Subgrade Inspections—special
05/24/2022Subsurface Conditions – Fill Placement & In-Place Density—special
05/24/2022Subsurface Investigations (Borings/Test Pits)GEORGE CAMBOURAKISspecial
05/24/2022Final—progress
05/24/2022Footing and Foundation—progress
05/23/2022Deep Foundation Elements—special
05/23/2022Subsurface Investigations (Borings/Test Pits)—special
05/17/2022Subsurface Conditions – Fill Placement & In-Place Density—special
05/17/2022Concrete - Cast-In-Place—special
05/17/2022Insulation placement and R values—energy_progress
05/17/2022Final—progress
05/17/2022Footing and Foundation—progress
05/17/2022Protection of exposed foundation insulation—energy_progress
05/17/2022Subgrade Inspections—special
05/02/2022Lighting in dwelling units—energy_progress
05/02/2022Exterior lighting power—energy_progress
Latest 25 of 47.
▾Documents — 85 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/29/2026B00724881-I1Request digital key ↗
08/29/2026B00724881-S1Request digital key ↗
08/29/2026B00742527-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits26
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION9
11/29/2018321249662Open ↗
11/29/2018321249662Open ↗
11/29/2018321249662Open ↗
Showing 3 of 9 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION8
12/11/2018321249662Open ↗
12/06/2018321249662Open ↗
11/23/2018321249662Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION7
07/19/2018321249662Open ↗
11/21/2017340437575Open ↗
11/23/2016321249662Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDEP Stormwater Construction Permit2
08/13/2026B00724881-S1Open ↗
08/13/2026B00724881-I1Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026B00724881-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B00724881-I1Open ↗
▸Seals & Professional Certifications19
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/29/2026B00724881-I1Open ↗
08/29/2026B00724881-S1Open ↗
08/29/2026B00742527-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/30/2026B00742527-I1Open ↗
08/30/2026B00742527-I1Open ↗
08/30/2026B00742527-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
10/27/2016340437575Open ↗
10/09/2015321249662Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/30/2026B00742527-I1Open ↗
08/30/2026B00742527-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/09/2015321249662Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/27/2016340437575Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
10/09/2015321249662Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/27/2016340437575Open ↗
▸Trade Schedules & Equipment8
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE6
12/11/2018321249662Open ↗
12/06/2018321249662Open ↗
11/23/2018321249662Open ↗
Showing 3 of 6 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA1
08/15/2018340437575Open ↗
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026B00724881-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/29/2026B00724881-I1Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/09/2015321249662Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
10/09/2015321249662Open ↗
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT4
08/29/2026B00742527-I1Open ↗
08/29/2026B00742527-P1Open ↗
08/29/2026B00742527-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram1
08/29/2026B00742527-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/29/2026B00742527-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
08/15/2018340437575Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
08/15/2018340437575Open ↗
10/27/2016340437575Open ↗
10/09/2015321249662Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION3
11/23/2018321249662Open ↗
06/09/2017321249662Open ↗
09/22/2016321249662Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/27/2016340437575Open ↗
▸BISBOROUGH INTAKE FORM1
08/15/2018340437575Open ↗
▸BISEFILING COVER SHEET1
10/09/2015321249662Open ↗
▸Other Documents5
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
10/27/2016340437575Open ↗
10/27/2016340437575Open ↗
▸BISPlot Diagram1
09/03/2014300685603Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B00724881-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/29/2026B00724881-I1Open ↗