← Back
BuildNYC
Elevator apt, fireproof with stores
7W57
7 WEST 57TH STREET · BIN 1035072
💬 Discuss this project
2018Year Built
19Stories
D6Building Class
C5-3Zoning
44,550 sfGross Floor Area
17Units
LL97 CoveredRent Stabilized0 Active Violations
Elevator apt, fireproof with stores · Owner of record: 7 West 57th Street Realty Company · 3,216 sf lot · 13.85 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 2Abel Richard13p · 4 filings · 20 docs
Floor 1Abel Richard13p · 9 filings · 20 docs
CellarAbel Richard13p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Solow Realty Development Company2303/21/2026
Second Ave Solow Development1203/21/2026
7 W57 St Realty Company703/21/2026
7 West 57th Street Realty Company103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HNY Consulting Engineers507/31/2026
Armour Unsderfer Engineering Inc, P207/02/2026
TPG Architecture207/01/2026
IW Architecture101/06/2026
WSP101/29/2025
Highland Associates201/13/2025
Universal Builders Supply309/04/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Milrose Consultants603/21/2026
New York Sign Consultants203/21/2026
Codegreen303/21/2026
Eurocelt Expediting603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Schimenti Construction CoGeneral Contractor605/29/2026
Universal Builders SupplyScaffold507/08/2026
Benchmark BuildersGeneral Contractor307/08/2026
Allstate SprinklerFire Protection207/08/2026
Capitol Fire Sprinkler CoFire Protection107/08/2026
Vallesigns & AwningsSign hanger107/08/2026
Bedrock Plumbing & HeatingPlumbing106/28/2026
Difazio Electric NYElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Crosscheck Inspection Services544907/31/2026
Codegreen510301/29/2025
Building Lifecycle
All (132)Filed (16)Permit Issued (16)Signed Off (8)Violation (55)Inspection (7)Special Inspection (30)
09/22/2026
Signed off — Alteration
Interior renovation as per plans filed herewith. No change in use, egress or occupancy.
M01198079-I1
07/31/2026
Filed — Alteration
New installation and modifications to plumbing, sprinkler systems & standpipe systems as per plans filed herewith.
M01204482-P2
07/09/2026
Signed off — Alteration
Provide new duct work, air devices, and VRF indoor units as per plans filed herewith. No change in use, egress or occupancy.
M01200496-I1
07/09/2026
Signed off — Alteration
Slab Infill and Unistrut support framing for hanging mechanical units. No change in use, egress or occupancy.
M01200476-I1
07/06/2026
Special inspection requirement — Final
Thomas Hughes
07/06/2026
Special inspection requirement — Post-installed Anchors
EUGENE BIFULCO
07/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
EUGENE BIFULCO
07/06/2026
Special inspection requirement — Tenant Protection Plan Compliance
EUGENE BIFULCO
07/06/2026
Special inspection requirement — Fire-Resistance Rated Construction
EUGENE BIFULCO
07/06/2026
Special inspection requirement — Post-installed Anchors
EUGENE BIFULCO
07/06/2026
Special inspection requirement — Duct leakage testing, insulation and design
EUGENE BIFULCO
07/06/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
EUGENE BIFULCO
07/06/2026
Special inspection requirement — HVAC-R and service water heating system controls
EUGENE BIFULCO
07/06/2026
Special inspection requirement — HVAC-R and service water heating equipment
EUGENE BIFULCO
07/06/2026
Special inspection requirement — Final
EUGENE BIFULCO
07/06/2026
Special inspection requirement — Tenant Protection Plan Compliance
EUGENE BIFULCO
07/06/2026
Special inspection requirement — Heating Systems
EUGENE BIFULCO
07/06/2026
Special inspection requirement — Mechanical Systems
EUGENE BIFULCO
07/02/2026
Filed — Alteration
Slab Infill and Unistrut support framing for hanging mechanical units. No change in use, egress or occupancy.
M01200476-P1
07/01/2026
Filed — Alteration
Interior renovation as per plans filed herewith. No change in use, egress or occupancy.
M01198079-P1
07/01/2026
Filed — Alteration
Provide new duct work, air devices, and VRF indoor units as per plans filed herewith. No change in use, egress or occupancy.
M01200496-P1
06/22/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/22/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/22/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/17/2026
Special inspection requirement — Tenant Protection Plan Compliance
06/15/2026
Special inspection requirement — Final
EUGENE BIFULCO
06/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
EUGENE BIFULCO
06/15/2026
Special inspection requirement — Post-installed Anchors
EUGENE BIFULCO
06/15/2026
Special inspection requirement — Sprinkler Systems
EUGENE BIFULCO
06/15/2026
Special inspection requirement — Standpipe Systems
EUGENE BIFULCO
06/15/2026
Special inspection requirement — Heating Systems
EUGENE BIFULCO
06/15/2026
Special inspection requirement — Mechanical Systems
EUGENE BIFULCO
06/15/2026
Special inspection requirement — Post-installed Anchors
EUGENE BIFULCO
06/15/2026
Special inspection requirement — Final
EUGENE BIFULCO
06/15/2026
Special inspection requirement — Duct leakage testing, insulation and design
EUGENE BIFULCO
06/15/2026
Special inspection requirement — HVAC-R and service water heating equipment
EUGENE BIFULCO
06/15/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
EUGENE BIFULCO
05/19/2026
Permit issued — General Construction
M01198079-I1-GC
04/14/2026
Signed off — Alteration
ERECT NON-ILLUMINATED ACCESSORY BUSINESS WALL SIGN ON EXISTING MULLION, NON-FLASHING, NON-ADVERTISING SIGN, NO CHANGE IN USE, EGRESS, OR OCCUPANCY
M01226018-I1
03/26/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/26/2026
Inspection — Certified StandPipe-SD-Fixtures-Finish-SD
Certified
View inspection ↗
03/24/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/24/2026
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
01/07/2026
Permit issued — Sign
M01226018-I1-SG
01/06/2026
Filed — Alteration
ERECT NON-ILLUMINATED ACCESSORY BUSINESS WALL SIGN ON EXISTING MULLION, NON-FLASHING, NON-ADVERTISING SIGN, NO CHANGE IN USE, EGRESS, OR OCCUPANCY
M01226018-I1
11/03/2025
Signed off — Alteration
SPRINKLER MODIFICATIONS TAKING PLACE ON 1ST FLOOR AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M01155133-I1
10/06/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/11/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/05/2025
Signed off — Alteration
STRUCTURAL MODIFICATIONS TAKING PLACE ON 1ST FLOOR AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M01155126-I1
08/01/2025
Signed off — Alteration
GENERAL CONSTRUCTION TAKING PLACE ON 1ST FLOOR AS PER PLANS FILED HEREWITH. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
M01155123-I1
07/18/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/14/2025
Filed — Alteration
New installation and modifications to plumbing, sprinkler systems & standpipe systems as per plans filed herewith.
M01204482-P1
06/03/2025
Permit issued — Plumbing
M01204482-I1-EW-SP
06/02/2025
Permit issued — Plumbing
M01204482-I1-EW-SD
05/21/2025
Permit issued — Sprinklers
M01204482-I1-PL
05/13/2025
Permit issued — Structural
M01200476-I1-ST
05/13/2025
Permit issued — Mechanical Systems
M01200496-I1-MS
05/02/2025
Permit issued — General Construction
M01198079-I1-GC
04/09/2025
Filed — Alteration
Slab Infill and Unistrut support framing for hanging mechanical units. No change in use, egress or occupancy.
M01200476-I1
04/08/2025
Filed — Alteration
Provide new duct work, air devices, and VRF indoor units as per plans filed herewith. No change in use, egress or occupancy.
M01200496-I1
Latest 60 of 132 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offSchimenti Construction Co05/19/2026
DOB NOWSignSigned-offVallesigns & Awnings01/07/2026
DOB NOWSprinklersSigned-offAllstate Sprinkler06/03/2025
DOB NOWStandpipeSigned-offAllstate Sprinkler06/02/2025
DOB NOWPlumbingPermit IssuedBedrock Plumbing & Heating05/21/2025
DOB NOWStructuralSigned-offSchimenti Construction Co05/13/2025
DOB NOWMechanical SystemsSigned-offSchimenti Construction Co05/13/2025
DOB NOWGeneral ConstructionSigned-offSchimenti Construction Co05/02/2025
DOB NOWStructuralSigned-offBenchmark Builders03/14/2025
DOB NOWSprinklersSigned-offCapitol Fire Sprinkler Co02/12/2025
DOB NOWGeneral ConstructionSigned-offBenchmark Builders01/29/2025
DOB NOWSidewalk ShedSigned-offUniversal Build Supp09/20/2021
DOB NOWSidewalk ShedSigned-offUniversal Build Supp09/15/2020
DOB NOWSidewalk ShedSigned-offUniversal Build Supp09/23/2019
DOB NOWSidewalk ShedSigned-offUniversal Build Supp10/02/2018
DOB NOWSidewalk ShedSigned-offUniversal Build Supp03/09/2018
BIS—ISSUEDSecond Ave Solow Development03/29/2022
BIS—ISSUEDSecond Ave Solow Development12/28/2021
BISOTISSUEDSecond Ave Solow Development12/14/2021
BIS—ISSUEDSecond Ave Solow Development10/05/2021
BISEQISSUEDSecond Ave Solow Development09/15/2021
BIS—ISSUEDSecond Ave Solow Development08/09/2021
BIS—ISSUEDSecond Ave Solow Development07/22/2021
BIS—ISSUEDSecond Ave Solow Development04/05/2021
BISSPISSUEDAshlar Mechanical02/26/2021
BISEQISSUEDGreg Logistics01/06/2021
BISPLISSUEDOlympic Plumbing & Heating Service12/28/2020
BIS—ISSUEDSecond Ave Solow Development12/23/2020
BISEQISSUEDSecond Ave Solow Development09/15/2020
BISBLISSUEDAccurate Mechanical09/11/2020
BIS—ISSUEDSecond Ave Solow Development06/29/2020
BIS—ISSUEDSecond Ave Solow Development06/01/2020
BISBLISSUEDAccurate Mechanical02/28/2020
BISEQISSUEDGreg Logistics01/10/2020
BISPLISSUEDOlympic Plumbing & Heating Service01/06/2020
BISSDISSUEDCurrent Fire Protection07/19/2019
BIS—ISSUEDSecond Ave Solow Development06/05/2019
BISEQISSUEDUniversal Builders Supply02/01/2019
BISEQISSUEDGreg Logistics01/17/2019
BISPLISSUEDOlympic Plumbing & Heating Service01/14/2019
+ 26 more permits on file
1 project · most recent 07/01/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/01/2026Signed-offSchimenti Construction CoHeating and Air Conditioning Systems
Heat / Cool
Hitachi HIDH027B22S 24 BTU · Vrf Indoor ×1
HIDH030B22S 27 BTU · Ahu ×1
HIDH036B22S 33 BTU · Heat Pump Outdoor ×1
HIDH054B22S 49 BTU · Heat Pump Outdoor ×1
TIAH60B22S 57 BTU · Vrf Outdoor ×1
1 project · most recent 07/31/2026
FiledStatusContractorScope
07/31/2026Signed-offAllstate Sprinkler108 heads, 4 outlets
1 project · most recent 07/31/2026
Storm Water/Sanitary
FiledStatusContractorScope
07/31/2026Permit IssuedBedrock Plumbing & HeatingStorm, Water/Sanitary
8 projects · most recent 05/21/2025
General Wiring
FiledStatusContractorScope
05/21/2025CompleteMer ElectricGeneral Wiring
11/18/2020CompleteLivingston Electrical AssociatesGeneral Wiring
07/18/2018CompleteDifazio Electric NY—
07/18/2018CompleteDifazio Electric NY—
02/14/2018CompleteLivingston Electrical Associates—
01/30/2018CompleteLivingston Electrical Associates—
01/30/2018CompleteLivingston Electrical Associates—
01/30/2018CompleteLivingston Electrical Associates—
1 project · most recent 07/02/2026
Concrete
FiledStatusContractorScope
07/02/2026Signed-offSchimenti Construction CoConcrete
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
03/26/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/26/2026Certified StandPipe-SD-Fixtures-Finish-SDCertifiedView ↗
03/24/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/24/2026Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
10/06/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/11/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/18/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 51
DateRequirementInspectorRole
07/06/2026FinalThomas Hughesprogress
07/06/2026Post-installed AnchorsEUGENE BIFULCOspecial
07/06/2026Fire-Resistant Penetrations and JointsEUGENE BIFULCOspecial
07/06/2026Tenant Protection Plan ComplianceEUGENE BIFULCOspecial
07/06/2026Fire-Resistance Rated ConstructionEUGENE BIFULCOprogress
07/06/2026Post-installed AnchorsEUGENE BIFULCOspecial
07/06/2026Duct leakage testing, insulation and designEUGENE BIFULCOenergy_progress
07/06/2026HVAC-R and service water piping design and insulationEUGENE BIFULCOenergy_progress
07/06/2026HVAC-R and service water heating system controlsEUGENE BIFULCOenergy_progress
07/06/2026HVAC-R and service water heating equipmentEUGENE BIFULCOenergy_progress
07/06/2026FinalEUGENE BIFULCOprogress
07/06/2026Tenant Protection Plan ComplianceEUGENE BIFULCOspecial
07/06/2026Heating SystemsEUGENE BIFULCOspecial
07/06/2026Mechanical SystemsEUGENE BIFULCOspecial
06/22/2026Tenant Protection Plan Compliance—special
06/22/2026Tenant Protection Plan Compliance—special
06/22/2026Tenant Protection Plan Compliance—special
06/17/2026Tenant Protection Plan Compliance—special
06/15/2026FinalEUGENE BIFULCOprogress
06/15/2026Fire-Resistant Penetrations and JointsEUGENE BIFULCOspecial
06/15/2026Post-installed AnchorsEUGENE BIFULCOspecial
06/15/2026Sprinkler SystemsEUGENE BIFULCOspecial
06/15/2026Standpipe SystemsEUGENE BIFULCOspecial
06/15/2026Heating SystemsEUGENE BIFULCOspecial
06/15/2026Mechanical SystemsEUGENE BIFULCOspecial
Latest 25 of 51.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Abel RichardOfficeCellar, Floors 1, 2
Project M01200476 Alteration · LOC Issued · 04/09/2025
Project M01200496 Alteration · LOC Issued · 04/08/2025
Project M01204482 Alteration · Permit Entire · 04/08/2025
Project M01198079 Alteration · LOC Issued · 04/07/2025
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 575 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch14
09/05/2026M00012659-I1Request digital key ↗
08/25/2026M01155133-I1Request digital key ↗
08/25/2026M01155123-I1Request digital key ↗
Showing 3 of 14 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed3
09/05/2026M00012659-I1Request digital key ↗
08/15/2026M00012659-P1Request digital key ↗
08/15/2026M00012659-P2Request digital key ↗
▸Applications & Permits122
▸BISPLAN / WORK APPROVAL APPLICATION85
01/27/2025121191441Open ↗
01/23/2025121191441Open ↗
07/18/2023123434603Open ↗
Showing 3 of 85 on file for this type
▸BISWORK PERMIT APPLICATION34
12/14/2021141006284Open ↗
02/26/2021140711969Open ↗
02/26/2021140711969Open ↗
Showing 3 of 34 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation2
04/08/2022140588193Open ↗
Showing 1 of 2 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Zoning, Tax Lot & Property Records7
▸BISZONING DIAGRAM5
06/15/2022121191441Open ↗
04/06/2022121191441Open ↗
08/31/2021121191441Open ↗
Showing 3 of 5 on file for this type
▸BISEASEMENT AND RESTRICTIVE DECLARATIONS - SUPPPORTING DOCUMENTATION2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Seals & Professional Certifications100
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION27
05/14/2019123456018Open ↗
Showing 1 of 27 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature16
09/05/2026M00012659-I1Open ↗
09/05/2026M00012659-P2Open ↗
09/05/2026M00012659-P1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature15
09/01/2026M01200476-P1Open ↗
09/01/2026M01155133-I1Open ↗
08/29/2026M01200496-P1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
09/01/2026M01200476-P1Open ↗
08/29/2026M01200496-P1Open ↗
08/29/2026M01200496-P1Open ↗
Showing 3 of 13 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT10
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 10 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISAPPLICANT OWNER SIGNATURE4
12/01/2021141006284Open ↗
Showing 1 of 4 on file for this type
▸Trade Schedules & Equipment32
▸BISSCHEDULE B - PLUMBING16
12/18/2020121191441Open ↗
12/09/2020121191441Open ↗
11/25/2020140711969Open ↗
Showing 3 of 16 on file for this type
▸BISEQUIPMENT USE PERMITS7
06/14/2023121191441Open ↗
06/14/2023121191441Open ↗
06/14/2023121191441Open ↗
Showing 3 of 7 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA2
07/18/2024123434603Open ↗
09/08/2022122980621Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT2
06/14/2023121191441Open ↗
06/14/2023121191441Open ↗
▸BISFIRE PROTECTION PLAN (FPP): FDNY APPROVAL1
03/14/2022121191441Open ↗
▸BISGAS CUT-OFF1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISHEATING SYSTEMS1
02/14/2022121191441Open ↗
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
03/08/2022121191441Open ↗
▸BIS* SEWER CONNECTION: DEP SD1 & SD21
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Safety & Tenant Protection10
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISSTREET TREE CHECKLIST2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSRO MD ANTI-HARASSMENT CHECKLIST1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos4
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸Energy Compliance29
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY12
03/11/2022140711763Open ↗
12/14/2021141006284Open ↗
02/28/2020140711763Open ↗
Showing 3 of 12 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
03/11/2022140711763Open ↗
Showing 1 of 2 on file for this type
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISFENESTRATION AIR LEAKAGE1
03/08/2022121191441Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
03/08/2022121191441Open ↗
▸BISLIGHTING CONTROLS1
03/08/2022121191441Open ↗
▸BISINTERIOR LIGHTING POWER1
03/08/2022121191441Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
03/08/2022121191441Open ↗
▸BISEXTERIOR LIGHTING POWER1
03/08/2022121191441Open ↗
▸Inspections & Test Reports41
▸BISTECHNICAL REPORT: RESPONSIBILITY31
03/15/2022121191441Open ↗
03/15/2022121191441Open ↗
03/15/2022121191441Open ↗
Showing 3 of 31 on file for this type
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTR2: CONCRETE FIELD TESTING TECHNICAL REPORT2
04/12/2022121191441Open ↗
03/11/2022121191441Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)2
04/12/2022121191441Open ↗
03/10/2022121191441Open ↗
▸BISSTRUCTURAL STEEL - DETAILS1
02/14/2022121191441Open ↗
▸BISHYDRAULIC FLOW CALCULATIONS1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
02/14/2022121191441Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
02/14/2022121191441Open ↗
▸Approvals, Objections & Sign-offs53
▸BISLETTERS - SUPPORTING DOCUMENTATION19
11/21/2019140711763Open ↗
Showing 1 of 19 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE16
01/27/2025121191441Open ↗
01/23/2025121191441Open ↗
06/01/2022121191441Open ↗
Showing 3 of 16 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST14
07/24/2024123434603Open ↗
09/19/2022122980621Open ↗
03/11/2022140711763Open ↗
Showing 3 of 14 on file for this type
▸BISCONSTRUCTION CODE DETERMINATION2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSUPERSEDING LETTER2
02/26/2021140711969Open ↗
Showing 1 of 2 on file for this type
▸Cost, Insurance & Ownership13
▸BISCOST AFFIDAVIT6
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 6 on file for this type
▸BISPROJECT-SPECIFIC GL INSURANCE5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
07/16/2024123434603Open ↗
12/07/2021140825533Open ↗
▸Filing & Intake Forms88
▸BISADDITIONAL INFORMATION54
06/15/2022121191441Open ↗
06/08/2022121191441Open ↗
04/06/2022121191441Open ↗
Showing 3 of 54 on file for this type
▸BISEFILING COVER SHEET16
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 16 on file for this type
▸BISBOROUGH INTAKE FORM9
02/19/2020140825533Open ↗
12/09/2019140825533Open ↗
Showing 2 of 9 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET9
12/01/2021141006284Open ↗
Showing 1 of 9 on file for this type
▸Other Documents11
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION7
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 7 on file for this type
▸BISSupporting Document: Fee Exempt2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISON-SITE STORM WATER DRAIN. DISP. /DETENT INSTALL (DRYWELL)1
03/08/2022121191441Open ↗
▸BISSHUTOFF DAMPERS1