← Back
Walk-up cooperative
Glen Oaks Village
70-07 261 STREET · BIN 4456568
💬 Discuss this project
1948Year Built
2Stories
C6Building Class
R3-2Zoning
84,976 sfGross Floor Area
120Units
LL97 CoveredRent Stabilized1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Walk-up cooperative · Owner of record: GLEN OAKS VILLAGE OWNERS INC · 263,750 sf lot · 0.32 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Floor 22p · 1 filing · 5 docs
Floor 1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SOLANKI ENGINEERING, PC107/31/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JP HOME CONSTRUCTION CORPGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SOLANKI ENGINEERING, P.C.8451107/31/2025
Building Lifecycle
All (11)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (8)
09/04/2025
Signed off — Alteration
INSTALLATION OF NEW REAR BALCONY WITH NEW ENTRY DOOR FROM SECOND FLOOR BEDROOM. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01235787-I1
08/06/2025
Permit issued — General Construction
Q01235787-I1-GC-CX
07/31/2025
Filed — Alteration
INSTALLATION OF NEW REAR BALCONY WITH NEW ENTRY DOOR FROM SECOND FLOOR BEDROOM. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01235787-I1
06/03/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Ashray Solanki
06/03/2025
Special inspection requirement — Concrete - Cast-In-Place
Ashray Solanki
06/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ashray Solanki
06/03/2025
Special inspection requirement — Subgrade Inspections
Ashray Solanki
06/03/2025
Special inspection requirement — Final
Ashray Solanki
06/03/2025
Special inspection requirement — Footing and Foundation
Ashray Solanki
06/03/2025
Special inspection requirement — Fire-Resistance Rated Construction
Ashray Solanki
06/03/2025
Special inspection requirement — Structural Wood Frame
Ashray Solanki
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offJP HOME CONSTRUCTION CORP08/06/2025
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
06/03/2025Structural Stability – Alterations of existing buildingsAshray Solankispecial
06/03/2025Concrete - Cast-In-PlaceAshray Solankispecial
06/03/2025Fire-Resistant Penetrations and JointsAshray Solankispecial
06/03/2025Subgrade InspectionsAshray Solankispecial
06/03/2025FinalAshray Solankiprogress
06/03/2025Footing and FoundationAshray Solankiprogress
06/03/2025Fire-Resistance Rated ConstructionAshray Solankiprogress
06/03/2025Structural Wood FrameAshray Solankiprogress
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/19/2026Q01235787-I1Request digital key ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/19/2026Q01235787-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/29/2026Q01235787-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/29/2026Q01235787-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/19/2026Q01235787-I1Open ↗