← Back
Two stories - detached, small or mid-size
70-15 JUNO STREET
QUEENS · BIN 4077299
💬 Discuss this project
1940Year Built
2.5Stories
A1Building Class
R2Zoning
2,392 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,000 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/26/2024$1.8M—Private party → Private party$753/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THINK DESIGN ARCHITECTURE210/22/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ESSENTIA BUILDERS LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THINK DESIGN ARCHITECTURA683210/22/2024
Building Lifecycle
All (10)Filed (2)Permit Issued (1)Signed Off (1)Inspection (3)Special Inspection (3)
07/07/2025
Signed off — Alteration
Application filed for the plumbing work associated with the interior alteration to existing 1 family 2 story residence.
Q01121719-I1
07/03/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/28/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/19/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
12/30/2024
Permit issued — General Construction
Q01121719-I1-GC
10/22/2024
Filed — Alteration
Application filed for the plumbing work associated with the interior alteration to existing 1 family 2 story residence.
Q01121719-I1
10/22/2024
Filed — Alteration
Application filed for the plumbing work associated with the interior alteration to existing 1 family 2 story residence.
Q01121719-S1
10/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Frank Martarella III
10/03/2024
Special inspection requirement — Energy Code Compliance Inspections
Frank Martarella III
10/03/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Frank Martarella III
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offESSENTIA BUILDERS12/30/2024
1 project · most recent 10/22/2024
Gas Water/Sanitary
FiledStatusContractorScope
10/22/2024——Gas, Water/Sanitary
1 project · most recent 12/27/2024
General Wiring
FiledStatusContractorScope
12/27/2024CompleteK.A.B. ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/03/2025Pass-Final General Construction Non-Directive 14PassView ↗
03/28/2025Fail-Final General Construction Non-Directive 14FailView ↗
03/19/2025Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
10/03/2024Fire-Resistant Penetrations and JointsFrank Martarella IIIspecial
10/03/2024Energy Code Compliance InspectionsFrank Martarella IIIprogress
10/03/2024HVAC-R and service water piping design and insulationFrank Martarella IIIenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026Q01121719-I1Request digital key ↗
08/21/2026Q01121719-S1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026Q01121719-I1Open ↗
08/21/2026Q01121719-S1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026Q01121719-S1Open ↗
08/27/2026Q01121719-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026Q01121719-S1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026Q01121719-I1Open ↗
08/21/2026Q01121719-S1Open ↗