← Back
Walk-up cooperative
Glen Oaks Village
70-43 LITTLE NECK PARKWAY · Glen Oaks-Floral Park-New Hyde Park · BIN 4459027
💬 Discuss this project
1948Year Built
2Stories
C6Building Class
R3-2Zoning
179,864 sfGross Floor Area
228Units
LL97 CoveredRent Stabilized0 Open Violations
Walk-up cooperative · Owner of record: GLEN OAKS VILLAGE OWNERS INC · 432,000 sf lot · 0.42 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Cellar2p · 1 filing · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GLEN OAKS VILLAGE OWNER'S INC.903/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MIELE ASSOCIATES, LLP205/30/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MIELE ASSOCIATES, LLP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
COMPASS CONSTRUCTION OF NGeneral Contractor403/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREYSTONE ENGINEERING CON2973205/30/2024
Building Lifecycle
All (19)Filed (2)Permit Issued (2)Signed Off (1)Violation (3)Inspection (1)Objection (6)Special Inspection (4)
07/10/2024
Signed off — Alteration
Complete emergency work related to the replacement and/or repair of existing garage doors and an existing column at the cellar to resolve DOB violations 040324FEU41301PN and 040324FEU41302PN. There is no proposed change in occupancy, use or egress.
Q01031208-I1
07/08/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
06/26/2024
Permit issued — General Construction
Q01031208-I1-ST
06/14/2024
Special inspection requirement — Concrete - Cast-In-Place
TIMOTHY TWEEDY
06/14/2024
Special inspection requirement — Structural Steel - Details
TIMOTHY TWEEDY
06/14/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TIMOTHY TWEEDY
06/14/2024
Special inspection requirement — Final
TIMOTHY TWEEDY
06/11/2024
Objection raised — Scope
06/11/2024
Objection resolved — Addressed
06/06/2024
Objection raised — Scope
06/06/2024
Objection resolved — Addressed
05/30/2024
Filed — Alteration
Complete emergency work related to the replacement and/or repair of existing garage doors and an existing column at the cellar to resolve DOB violations 040324FEU41301PN and 040324FEU41302PN. There is no proposed change in occupancy, use or egress.
Q01031208-P1
05/23/2024
Permit issued — General Construction
Q01031208-I1-GC
05/02/2024
Objection raised — Zoning
05/02/2024
Objection resolved — Addressed
04/26/2024
Filed — Alteration
Complete emergency work related to the replacement and/or repair of existing garage doors and an existing column at the cellar to resolve DOB violations 040324FEU41301PN and 040324FEU41302PN. There is no proposed change in occupancy, use or egress.
Q01031208-I1
04/03/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/03/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/03/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offCOMPASS CONSTRUCTION OF N06/26/2024
DOB NOWGeneral ConstructionSigned-offCOMPASS CONSTRUCTION OF N05/23/2024
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
07/08/2024Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
06/14/2024Concrete - Cast-In-PlaceTIMOTHY TWEEDYspecial
06/14/2024Structural Steel - DetailsTIMOTHY TWEEDYspecial
06/14/2024Structural Stability – Alterations of existing buildingsTIMOTHY TWEEDYspecial
06/14/2024FinalTIMOTHY TWEEDYprogress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/22/2026Q01031208-I1Request digital key ↗
08/22/2026Q01031208-I1Request digital key ↗
08/22/2026Q01031208-P1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWSpecial Inspector Seal & Signature3
08/30/2026Q01031208-I1Open ↗
08/30/2026Q01031208-I1Open ↗
08/30/2026Q01031208-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/22/2026Q01031208-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/30/2026Q01031208-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/22/2026Q01031208-P1Open ↗
08/22/2026Q01031208-I1Open ↗
08/22/2026Q01031208-I1Open ↗