← Back
BuildNYC
One story retail building
70 WEST 183RD STREET
BRONX · BIN 2014528
💬 Discuss this project
1920Year Built
1Stories
K1Building Class
R7AZoning
5,397 sfGross Floor Area
6Units
0 Active Violations
One story retail building · Owner of record: Banner Washing Machine Co · 6,947 sf lot · 0.78 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofCommercial kitchen hood installation1p · 1 filing · 5 docs
Floor 1Tamal Express6p · 2 filings · 16 docs
CellarTamal Express3p · 1 filing · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Banner Washing Machine Co203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BL Consultant203/11/2023
Associates101/17/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
H Design Studio403/21/2026
J Sibaja Kitchen Ventilation203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Accurate ElectricalElectrical403/21/2026
J. Sibaja Kitchen and VE*General Contractor207/08/2026
Danny RamnarianElectrical103/21/2026
Todaro JosephElectrical103/21/2026
CJ Heating & MechanicalPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AM Engineering Services P7975101/17/2023
IP Concrete Testing and I6252101/10/2023
Building Lifecycle
All (24)Filed (3)Permit Issued (3)Violation (6)Objection (8)Special Inspection (4)
10/29/2024
Permit issued — Mechanical Systems
X08036526-I1-MS
04/28/2023
Permit issued — Plumbing
X08045239-I1-PL
03/11/2023
Filed — Alteration
INSTALL COMMERCIAL COOKING EQUIPMENT AT 1ST FLOOR & CELLAR FOR EXISTING COMMERCIAL SPACE PER PROPOSED PLAN
X08045239-S1
03/11/2023
Special inspection requirement — Energy Code Compliance Inspections
BALDEMIRO LEON
03/11/2023
Special inspection requirement — Fire-Resistance Rated Construction
BALDEMIRO LEON
02/23/2023
Permit issued — Mechanical Systems
X08036526-I1-MS
01/19/2023
Objection raised — Zoning
01/19/2023
Objection resolved — Addressed
01/19/2023
Objection raised — Admin
01/19/2023
Objection resolved — Addressed
01/17/2023
Filed — Alteration
INSTALL NEW DUCT FOR EXISTING COMMERCIAL KITCHEN HOOD TYPE I, NO CHANGE OF USE EGRESS OR OCCUPANCY.
X08036526-I1
01/17/2023
Objection raised — Scope
01/17/2023
Objection resolved — Addressed
01/17/2023
Objection raised — Scope
01/17/2023
Objection resolved — Addressed
01/10/2023
Filed — Alteration
INSTALL COMMERCIAL COOKING EQUIPMENT AT 1ST FLOOR & CELLAR FOR EXISTING COMMERCIAL SPACE PER PROPOSED PLAN
X08045239-I1
01/10/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
INDARDEO PARBHUNATH
01/10/2023
Special inspection requirement — Energy Code Compliance Inspections
BALDEMIRO LEON
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V-DOB VIOLATION - ACTIVE
06/09/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedJ. Sibaja Kitchen and VE*10/29/2024
DOB NOWPlumbingPermit IssuedCJ Heating & Mechanical04/28/2023
DOB NOWMechanical SystemsPermit IssuedJ. Sibaja Kitchen and VE*02/23/2023
BISFPISSUEDMaster Fire Systems02/16/2001
1 project · most recent 01/17/2023
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/17/2023Permit IssuedJ. Sibaja Kitchen and VE*Ventilation Systems
Ventilation
Captiveaire DU180HFA 3,000 CFM ×1
Integrity Kitchen Supply TYPE II 3,000 CFM · Kitchen Exhaust ×1
1 project · most recent 03/11/2023
Gas Water/Sanitary
FiledStatusContractorScope
03/11/2023Permit IssuedCJ Heating & MechanicalGas, Water/Sanitary
1 project · most recent 11/15/2021
General Wiring
FiledStatusContractorScope
11/15/2021CompleteAccurate ElectricalGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
03/11/2023Energy Code Compliance InspectionsBALDEMIRO LEONprogress
03/11/2023Fire-Resistance Rated ConstructionBALDEMIRO LEONprogress
01/10/2023Fire-Resistant Penetrations and JointsINDARDEO PARBHUNATHspecial
01/10/2023Energy Code Compliance InspectionsBALDEMIRO LEONprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Tamal ExpressRestaurant / Food ServiceCellar, Floor 1
Project X08045239 Alteration · Permit Entire · 01/10/2023
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026X08045239-S1Request digital key ↗
08/15/2026X08036526-I1Request digital key ↗
08/14/2026X08045239-I1Request digital key ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/23/2026X08036526-I1Open ↗
08/23/2026X08045239-I1Open ↗
08/23/2026X08045239-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026X08045239-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026X08045239-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWOER: Notice to Proceed3
08/13/2026X08045239-S1Open ↗
08/13/2026X08045239-I1Open ↗
08/13/2026X08036526-I1Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/23/2026X08045239-S1Open ↗
08/15/2026X08036526-I1Open ↗
08/14/2026X08045239-I1Open ↗
▸DOB NOWOER: Notice of Satisfaction2
08/13/2026X08036526-I1Open ↗
08/13/2026X08045239-S1Open ↗