← Back
BuildNYC
One story retail building
7009 13TH AVENUE
BROOKLYN · Dyker Heights · BIN 3157053
💬 Discuss this project
2003Year Built
1Stories
K1Building Class
R6BZoning
10,550 sfGross Floor Area
1Units
2 Active Violations 0 unresolved · 2 paperwork only ▸FDNY Report ↗
One story retail building · 10,550 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofWalgreens Eastern Co5p · 2 filings · 9 docs
Floor 5Walgreens1p · 2 filings · 4 docs
Floor 4Walgreens1p · 2 filings · 4 docs
Floor 3Walgreens1p · 2 filings · 4 docs
Floor 2Walgreens1p · 2 filings · 4 docs
Floor 1Walgreens2p · 3 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Walgreens Eastern Co407/08/2026
Unicoro National Developments203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Nic 88209/18/2024
Edward C. Hicks RA106/10/2022
Jose L. Pena, P.E205/11/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Louis Striar403/21/2026
Advanced Builders Services103/21/2026
Basic Groups403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Signstar NYCSign hanger207/08/2026
M. Fried Store FixturesGeneral Contractor107/08/2026
L&J PLG & Heating Co of NYPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Nic 888371209/18/2024
IP Concrete Testing and I6252106/10/2022
Building Lifecycle
All (45)Filed (5)Permit Issued (4)Signed Off (3)Violation (11)Inspection (2)Objection (10)Special Inspection (10)
11/21/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/18/2024
Filed — Alteration
Replace existing gas pipes in the existing 1 story building. Plumbing works as per plan. No change in egress, use, or occupancy.
B01026097-P1
09/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
09/12/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/25/2024
Permit issued — Plumbing
B01026097-I1-PL
03/28/2024
Filed — Alteration
Replace existing gas pipes in the existing 1 story building. Plumbing works as per plan. No change in egress, use, or occupancy.
B01026097-I1
09/26/2022
Signed off — Alteration
Mechanical application hereby filed for the replacement of existing HVAC units on the roof top of an existing commercial building. Mechanical specifications and work types.
B00749891-I1
08/12/2022
Permit issued — Mechanical Systems
B00749891-I1-MS
07/19/2022
Objection raised — Scope
07/19/2022
Objection resolved — Addressed
07/19/2022
Objection resolved — Addressed
07/19/2022
Special inspection requirement — Energy Code Compliance Inspections
EDWARD HICKS
07/12/2022
Objection raised — Inspections
07/12/2022
Objection raised — Admin
07/12/2022
Objection resolved — Addressed
07/12/2022
Objection raised — Scope
07/12/2022
Objection resolved — Addressed
07/12/2022
Special inspection requirement — Shutoff dampers
EDWARD HICKS
07/05/2022
Objection resolved — Addressed
06/20/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
EDWARD HICKS
06/20/2022
Special inspection requirement — Duct leakage testing, insulation and design
EDWARD HICKS
06/17/2022
Objection raised — Scope
06/10/2022
Filed — Alteration
Mechanical application hereby filed for the replacement of existing HVAC units on the roof top of an existing commercial building. Mechanical specifications and work types.
B00749891-I1
06/02/2022
Special inspection requirement — HVAC-R and service water heating system controls
EDWARD HICKS
06/02/2022
Special inspection requirement — HVAC-R and service water heating equipment
EDWARD HICKS
06/02/2022
Special inspection requirement — Maintenance information
EDWARD HICKS
06/02/2022
Special inspection requirement — Mechanical Systems
INDARDEO PARBHUNATH
06/02/2022
Special inspection requirement — Final
EDWARD HICKS
07/30/2019
Signed off — Alteration
B00158827-I1
07/30/2019
Signed off — Alteration
B00158855-I1
05/29/2019
Permit issued — Sign
B00158827-I1-SG
05/29/2019
Permit issued — Sign
B00158855-I1-SG
05/11/2019
Filed — Alteration
B00158827-I1
05/11/2019
Filed — Alteration
B00158855-I1
01/09/2015
Violation issued (FDNY_NOV, closed)
08/21/2014
Violation issued (FDNY_NOV, closed)
08/21/2014
Violation issued (FDNY_NOV, closed)
06/02/2014
Violation issued (FDNY_NOV, closed)
01/10/2014
Violation issued (FDNY_NOV, closed)
11/26/2008
Violation issued (FDNY_NOV, closed)
08/27/2008
Violation issued (FDNY_NOV, closed)
10/23/2002
Violation issued (ECB, closed)
Construction
10/23/2002
Violation issued (ECB, closed)
Site Safety
10/23/2002
Violation issued (ECB, open)
Construction
10/10/1997
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offL&J PLG & Heating Co of NY07/25/2024
DOB NOWMechanical SystemsSigned-offM. Fried Store Fixtures08/12/2022
DOB NOWSignSigned-offSignstar NYC05/29/2019
DOB NOWSignSigned-offSignstar NYC05/29/2019
BISEQRE-ISSUEDMC Apline Construction Co10/02/2002
BIS—ISSUEDDiversified Construction10/02/2002
1 project · most recent 09/18/2024
Gas
FiledStatusContractorScope
09/18/2024Signed-offL&J PLG & Heating Co of NYGas
4 projects · most recent 12/20/2022
FiledStatusContractorScope
12/20/2022CompleteRainbow Electric Co—
12/20/2022CompleteRainbow Electric Co—
05/31/2019CompleteRobert S. Covello—
05/31/2019CompleteAbco Electrical Cont—
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
11/21/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/12/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
09/18/2024Fire-Resistant Penetrations and JointsEric Sunspecial
07/19/2022Energy Code Compliance InspectionsEDWARD HICKSprogress
07/12/2022Shutoff dampersEDWARD HICKSenergy_progress
06/20/2022HVAC-R and service water piping design and insulationEDWARD HICKSenergy_progress
06/20/2022Duct leakage testing, insulation and designEDWARD HICKSenergy_progress
06/02/2022HVAC-R and service water heating system controlsEDWARD HICKSenergy_progress
06/02/2022HVAC-R and service water heating equipmentEDWARD HICKSenergy_progress
06/02/2022Maintenance informationEDWARD HICKSenergy_progress
06/02/2022Mechanical SystemsINDARDEO PARBHUNATHspecial
06/02/2022FinalEDWARD HICKSprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Walgreens Eastern CoRetailRoof
Project B00749891 Alteration · LOC Issued · 06/10/2022
WalgreensRetailFloors 1–5
Project B00158827 Alteration · LOC Issued · 05/11/2019
Project B00158855 Alteration · LOC Issued · 05/11/2019
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch - Sign2
09/02/2026B00158855-I1Request digital key ↗
09/02/2026B00158827-I1Request digital key ↗
▸DOB NOWPlans/Sketch2
08/25/2026B01026097-P1Request digital key ↗
08/15/2026B00749891-I1Request digital key ↗
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/02/2026B00158855-I1Open ↗
09/02/2026B00158827-I1Open ↗
08/25/2026B01026097-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026B00749891-I1Open ↗
08/28/2026B00749891-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026B00749891-I1Open ↗
08/25/2026B01026097-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00749891-I1Open ↗