← Back
BuildNYC
Walk-up apt, over six families with stores
701 EAST 175TH STREET
BRONX · BIN 2009949
💬 Discuss this project
1931Year Built
6Stories
C7Building Class
R7-1Zoning
15,070 sfGross Floor Area
24Units
Rent Stabilized226 Active Violations 222 unresolved · 4 paperwork only 1 likely answered ▸
Walk-up apt, over six families with stores · Owner of record: East 175th Realty · 3,510 sf lot · 4.29 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Floor 1East 175th Realty LLCUnder Construction6p · 2 filings · 20 docs
CellarEast 175th Realty LLCUnder Construction3p · 1 filing · 17 docs
Filed — no permit issued5p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
East 175th Realty1609/13/2026
Sun Doo Realty603/21/2026
Crotona Spark Shop103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Jung H. Choi, Architect204/02/2026
Ashraf202/08/2024
Gino O. Longo, Architect109/30/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Ma Designs NYC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Lina ElectricElectrical303/21/2026
Star Plumbing & HeatingPlumbing307/08/2026
WCK ElectricElectrical103/22/2026
3 Brothers Wood WorksGeneral Contractor106/28/2026
AlthaibaniGeneral Contractor107/08/2026
Signore & Sons PlumbingPlumbing108/07/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Jung H Choi Architect3020204/02/2026
Jay Kavi8500202/08/2024
Building Lifecycle
All (89)Filed (5)Permit Issued (4)Violation (60)Inspection (2)Objection (3)Special Inspection (15)
08/31/2026
Violation issued (HPD, open)
B
08/31/2026
Violation issued (HPD, open)
C
08/06/2026
Permit issued — Plumbing
X01329899-S1-PL
06/26/2026
Permit issued — General Construction
X01329899-I1-GC-CX
06/15/2026
Violation issued (HPD, open)
A
06/15/2026
Violation issued (HPD, open)
C
06/15/2026
Violation issued (HPD, open)
B
06/15/2026
Violation issued (HPD, open)
B
06/15/2026
Violation issued (HPD, open)
C
06/15/2026
Violation issued (HPD, open)
B
06/15/2026
Violation issued (HPD, open)
C
06/15/2026
Violation issued (HPD, open)
C
04/30/2026
Violation issued (HPD, open)
A
04/16/2026
Objection raised — Other
04/16/2026
Objection resolved — Resolved
04/10/2026
Violation issued (HPD, open)
A
04/10/2026
Violation issued (HPD, open)
B
04/10/2026
Violation issued (HPD, open)
B
04/10/2026
Violation issued (HPD, open)
B
04/10/2026
Violation issued (HPD, open)
B
04/10/2026
Violation issued (HPD, open)
A
04/10/2026
Violation issued (HPD, open)
B
04/10/2026
Violation issued (HPD, open)
B
04/10/2026
Violation issued (HPD, open)
B
04/10/2026
Violation issued (HPD, open)
B
04/10/2026
Objection raised — Other
04/02/2026
Filed — Alteration
Renovation of Existing Restaurant on First Floor as per Plans, Existing Mechanical Exhaust System for Commercial Cooking to Remain. This filing is in Conjunction with Fire Suppression (Ansul) System to be filed with FDNY.
X01329899-S1
04/02/2026
Filed — Alteration
Renovation of Existing Restaurant on First Floor as per Plans, Existing Mechanical Exhaust System for Commercial Cooking to Remain. This filing is in Conjunction with Fire Suppression (Ansul) System to be filed with FDNY.
X01329899-I1
02/21/2026
Violation issued (ECB, open)
Unknown
02/19/2026
Violation issued (HPD, open)
C
02/19/2026
Violation issued (HPD, open)
C
02/17/2026
Violation issued (HPD, open)
C
02/09/2026
Violation issued (HPD, closed)
C
02/09/2026
Violation issued (HPD, open)
C
02/09/2026
Violation issued (HPD, closed)
C
02/09/2026
Violation issued (HPD, open)
C
02/09/2026
Violation issued (HPD, closed)
C
02/09/2026
Violation issued (HPD, closed)
C
02/09/2026
Violation issued (HPD, closed)
C
02/09/2026
Violation issued (HPD, closed)
C
01/22/2026
Violation issued (HPD, open)
C
01/17/2026
Violation issued (HPD, closed)
C
01/17/2026
Violation issued (HPD, open)
B
01/17/2026
Violation issued (HPD, open)
C
01/17/2026
Violation issued (HPD, open)
B
01/17/2026
Violation issued (HPD, open)
C
01/17/2026
Violation issued (HPD, open)
C
01/17/2026
Violation issued (HPD, closed)
C
01/17/2026
Violation issued (HPD, closed)
C
01/17/2026
Violation issued (HPD, open)
B
01/17/2026
Violation issued (HPD, open)
C
01/17/2026
Violation issued (HPD, open)
B
01/17/2026
Violation issued (HPD, open)
B
01/17/2026
Violation issued (HPD, open)
B
12/19/2025
Violation issued (HPD, open)
B
12/19/2025
Violation issued (HPD, open)
B
12/19/2025
Violation issued (HPD, open)
C
12/19/2025
Violation issued (HPD, open)
A
12/19/2025
Violation issued (HPD, open)
C
12/19/2025
Violation issued (HPD, open)
C
Latest 60 of 89 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedSignore & Sons Plumbing08/06/2026
DOB NOWGeneral ConstructionPermit Issued3 Brothers Wood Works06/26/2026
DOB NOWPlumbingSigned-offStar Plumbing & Heating06/11/2024
DOB NOWGeneral ConstructionPermit IssuedAlthaibani03/01/2024
BISBLISSUEDJack Piccini02/07/2017
BISPLISSUEDHudson River Mechanical Group I04/14/2014
BISBLISSUEDHudson River Mechanical Group I04/14/2014
BISBLISSUEDSP Plumbing and Heating04/11/2013
BISPLISSUEDSP Plumbing and Heating04/11/2013
BISOTISSUEDMill & Mill Construction03/29/2011
BISEQISSUEDMill & Mill Construction03/29/2011
BISOTISSUEDSafeway Contractor07/01/2003
BISEQISSUEDSpring Scaffolding04/23/2003
BISPLISSUEDFlytiger P & H12/30/2002
BISOTISSUEDNew Empire Construction12/16/2002
1 project · most recent 04/02/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/02/2026Permit Issued3 Brothers Wood WorksHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Gree GREE 34,000 BTU · Heat Pump Outdoor ×2
Ventilation
N/A N/A 65 CFM · Exhaust Fan ×1
1 project · most recent 04/02/2026
FiledStatusContractorScope
04/02/2026——6 heads
2 projects · most recent 04/02/2026
Water/Sanitary Gas Plumbing-Sprinkler
FiledStatusContractorScope
04/02/2026Permit IssuedSignore & Sons PlumbingGas, Plumbing-Sprinkler, Water/Sanitary
02/08/2024Signed-offStar Plumbing & HeatingWater/Sanitary
5 projects · most recent 01/06/2026
General Wiring
FiledStatusContractorScope
01/06/2026Permit IssuedLina ElectricGeneral Wiring
06/18/2025Permit IssuedLina ElectricGeneral Wiring
06/18/2025Permit IssuedLina ElectricGeneral Wiring
06/06/2024Permit IssuedWCK ElectricGeneral Wiring
02/06/2024Permit IssuedWCK ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
06/20/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/20/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
12/09/2025HVAC-R and service water heating equipmentJung Choienergy_progress
12/09/2025HVAC-R and service water heating system controlsJung Choienergy_progress
12/09/2025HVAC-R and service water piping design and insulationJung Choienergy_progress
12/09/2025Interior lighting powerJung Choienergy_progress
12/09/2025Tenant Protection Plan ComplianceJung Choispecial
12/09/2025Tenant Protection Plan ComplianceJung Choispecial
12/09/2025Lighting controlsJung Choienergy_progress
12/07/2025Fire-Resistance Rated ConstructionJung Choiprogress
12/07/2025Energy Code Compliance InspectionsJung Choiprogress
12/06/2025FinalJAMES CHENGprogress
12/06/2025Mechanical SystemsJung Choispecial
02/05/2024Tenant Protection Plan ComplianceJay Kavispecial
02/04/2024Tenant Protection Plan ComplianceJay Kavispecial
02/04/2024Fire-Resistant Penetrations and JointsJay Kavispecial
01/26/2024FinalBRIAN MCCAFFREYprogress
▾Documents — 89 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/25/2026X00584593-I1Request digital key ↗
08/21/2026X00996990-S2Request digital key ↗
08/21/2026X00996990-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits13
▸BISWORK PERMIT APPLICATION9
02/07/2017220579309Open ↗
02/07/2017220579309Open ↗
04/25/2014240022667Open ↗
Showing 3 of 9 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
02/07/2017220579309Open ↗
04/01/2013240022667Open ↗
06/12/2012220209548Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications34
▸DOB NOWProgress Inspector Seal & Signature9
08/26/2026X00996990-I1Open ↗
08/24/2026X01329899-I1Open ↗
08/24/2026X01329899-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/28/2026X01329899-S1Open ↗
08/26/2026X00996990-I1Open ↗
08/26/2026X00996990-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
06/06/2017220579309Open ↗
02/07/2017220579309Open ↗
02/07/2017220579309Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/25/2026X00584593-I1Open ↗
08/21/2026X00996990-I1Open ↗
08/21/2026X00996990-S2Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
02/07/2017220579309Open ↗
06/12/2012220209548Open ↗
03/30/2011220110564Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
02/07/2017220579309Open ↗
04/01/2013240022667Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
06/12/2012220209548Open ↗
03/30/2011220110564Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/01/2013240022667Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
04/01/2013240022667Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
02/07/2017220579309Open ↗
04/01/2013240022667Open ↗
▸BISSCHEDULE B - PLUMBING2
04/01/2013240022667Open ↗
06/12/2012220209548Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
06/06/2017220579309Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
06/12/2012220209548Open ↗
▸BISTenant Protection Plan and Notes1
02/07/2017220579309Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/25/2026X00584593-I1Open ↗
08/21/2026X00996990-I1Open ↗
08/21/2026X00996990-S2Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
02/07/2017220579309Open ↗
04/01/2013240022667Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
06/12/2012220209548Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
03/30/2011220110564Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
06/06/2017220579309Open ↗
02/07/2017220579309Open ↗
02/07/2017220579309Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
04/01/2013240022667Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/06/2017220579309Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
04/01/2013240022667Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
04/01/2013240022667Open ↗
▸Approvals, Objections & Sign-offs5
▸BISLETTERS - SUPPORTING DOCUMENTATION2
06/06/2017220579309Open ↗
04/25/2014240022667Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
06/12/2012220209548Open ↗
03/30/2011220110564Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
06/06/2017220579309Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
06/06/2017220579309Open ↗
02/07/2017220579309Open ↗
04/01/2013240022667Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
02/07/2017220579309Open ↗
06/12/2012220209548Open ↗
03/30/2011220110564Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/01/2013240022667Open ↗