| Owner | Filings | Most Recent |
|---|---|---|
| MS INVESTMENTS 3 | 15 | 07/08/2026 |
| 701 VAN SICLEN LLC | 1 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/21/2025 | $1.1M | — | TIMMOLT WALSH PROPERTIES INC. → 701 VAN SICLEN LLC | $305/sf building |
| 12/02/2014 | $325K | — | Private party → DEED LEADERS INC. | $89/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| AG ENGINEERING PLLC | 4 | 08/27/2025 |
| VASILIOS ARTEMIOU PE | 1 | 04/22/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| BMG GROUP USA | 4 | 03/21/2026 |
| XPDITE GROUP LLC (104) | 1 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| REVAMP NYC CORP | General Contractor | 2 | 04/09/2026 |
| AMOK INC | Fire Protection | 1 | 07/08/2026 |
| AMOK INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| SHAHRISH SHUVO ENGINEERIN | 8524 | 5 | 08/27/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | REVAMP NYC CORP | 06/06/2025 |
| DOB NOW | Sprinklers | Signed-off | AMOK INC | 05/23/2025 |
| DOB NOW | Plumbing | Signed-off | AMOK INC | 05/23/2025 |
| DOB NOW | Mechanical Systems | Signed-off | REVAMP NYC CORP | 05/22/2025 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/27/2025 | Permit Issued | REVAMP NYC CORP | Heating and Air Conditioning Systems | Heat / Cool Daikin DAIKIN- 2MXM18AVJU9
DAIKIN- RXF12BVJU9 18,500 BTU ×9 DAIKIN - 3MXM24AVJU9 24,000 BTU · Heat Pump Outdoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/27/2025 | Signed-off | AMOK INC | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/27/2025 | Signed-off | AMOK INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/08/2025 | Complete | AG POWER ELECTRIC CORP | General Wiring |
| 07/22/2025 | Complete | AG POWER ELECTRIC CORP | — |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/07/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 08/04/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 08/04/2025 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 07/31/2025 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 07/30/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 07/09/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 07/03/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 07/03/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 06/30/2025 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 06/25/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 06/25/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 06/11/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 09/12/2025 | Structural Stability – Alterations of existing buildings | Shahrish Shuvo | special |
| 09/12/2025 | Fire-Resistant Penetrations and Joints | Shahrish Shuvo | special |
| 09/12/2025 | Fire-Resistance Rated Construction | Shahrish Shuvo | progress |
| 09/12/2025 | Energy Code Compliance Inspections | Shahrish Shuvo | progress |
| 09/12/2025 | Air barrier - visual inspection | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Air barrier — testing | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Lighting in dwelling units | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Fenestration and door U-factor and product ratings | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Interior lighting power | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Exterior lighting power | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Lighting controls | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Fenestration areas | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Metering | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Permanent certificate | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Fenestration air leakage | Shahrish Shuvo | energy_progress |
| 09/12/2025 | Maintenance information | Shahrish Shuvo | energy_progress |
| 08/26/2025 | Fire-Resistant Penetrations and Joints | Shahrish Shuvo | special |
| 08/26/2025 | Structural Stability – Alterations of existing buildings | Shahrish Shuvo | special |
| 08/26/2025 | Energy Code Compliance Inspections | Shahrish Shuvo | progress |
| 08/26/2025 | Fire-Resistance Rated Construction | Shahrish Shuvo | progress |
| 08/26/2025 | Interior lighting power | Shahrish Shuvo | energy_progress |
| 08/26/2025 | Air barrier — testing | Shahrish Shuvo | energy_progress |
| 08/26/2025 | Maintenance information | Shahrish Shuvo | energy_progress |
| 08/26/2025 | Fenestration air leakage | Shahrish Shuvo | energy_progress |
| 08/26/2025 | Lighting controls | Shahrish Shuvo | energy_progress |