| Owner | Filings | Most Recent |
|---|---|---|
| MK IMPROVEMENT GROUP | 19 | 07/08/2026 |
| METRO CONTRACTING NY | 4 | 04/09/2026 |
| ZKW ENTERPRISES | 6 | 04/09/2026 |
| FACADE IMPROMENT INC | 1 | 03/22/2026 |
| BROWNSTONE DEVELOPERS | 4 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/21/2024 | $2.3M | — | Private party → MZK MANAGEMENT GROUP LLC | $606/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| DIAGRID CONSULTANTS | 1 | 07/20/2026 |
| KUSHNER STUDIOS | 3 | 06/09/2026 |
| HANSEN ENGINEERING, PC | 6 | 01/29/2026 |
| ASR ENGINEERING PC | 1 | 03/07/2025 |
| BASIC GROUPS CORP | 1 | 03/05/2025 |
| NEW AIR SOLUTION INC. | 1 | 02/27/2025 |
| SUPERIOR HOME INSPECTION SERVICES | 2 | 05/24/2024 |
| MSM ENGINEERING SERVICES, PLLC | 1 | 05/08/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| KUSHNER STUDIOS | 8 | 03/21/2026 |
| ADVANCED BUILDERS SERVICES | 1 | 03/21/2026 |
| Bealin Groups Corp | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| FACADE IMPROVEMENT INC | General Contractor | 8 | 07/08/2026 |
| ZKW ENTERPRISES INC | General Contractor | 4 | 04/09/2026 |
| NELSON & TOM MAINT INC DB | Electrical | 1 | 03/22/2026 |
| BEST PLUMBING & HVAC INC | Fire Protection | 1 | 07/08/2026 |
| METRO CONTRACTING NY, INC. | General Contractor | 1 | 04/09/2026 |
| AMC PLBG, HTG & CLNG, INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| AM ENGINEERING SERVICES P | 7975 | 9 | 06/09/2026 |
| BEALIN GROUPS CORP | 9869 | 1 | 03/05/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Plumbing | Signed-off | AMC PLBG, HTG & CLNG, INC | 08/29/2025 |
| DOB NOW | General Construction | Permit Issued | FACADE IMPROVEMENT INC | 07/22/2025 |
| DOB NOW | Sprinklers | Signed-off | BEST PLUMBING & HVAC INC | 07/22/2025 |
| DOB NOW | Mechanical Systems | Signed-off | FACADE IMPROVEMENT INC | 07/07/2025 |
| DOB NOW | General Construction | Permit Issued | FACADE IMPROVEMENT INC | 07/01/2025 |
| DOB NOW | Structural | Signed-off | FACADE IMPROVEMENT INC | 03/28/2025 |
| DOB NOW | Supported Scaffold | Signed-off | ZKW ENTERPRISES INC | 03/10/2025 |
| DOB NOW | Supported Scaffold | Signed-off | ZKW ENTERPRISES INC | 03/10/2025 |
| DOB NOW | Construction Fence | Signed-off | FACADE IMPROVEMENT INC | 03/03/2025 |
| DOB NOW | General Construction | Permit Issued | FACADE IMPROVEMENT INC | 02/24/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | METRO CONTRACTING NY, INC. | 05/08/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 06/09/2026 | Permit Issued | FACADE IMPROVEMENT INC | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Cooper & Hunter CH-HPR19M-230VO 19,000 BTU · Condensing Unit ×3 CH-HYP28MSPH-230VO 28,000 BTU · Condensing Unit ×3 CH-55MES-230VO 55,000 BTU · Condensing Unit ×1 CH-HRR36M-230VO 36,000 BTU · Condensing Unit ×1 CH-HYP12SPH-230VO 12,000 BTU · Condensing Unit ×1 Ventilation Renewaire HE071N 505 CFM · Erv ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/09/2026 | Signed-off | BEST PLUMBING & HVAC INC | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/09/2026 | Signed-off | AMC PLBG, HTG & CLNG, INC | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/04/2026 | Complete | NELSON & TOM MAINT INC DB | General Wiring |
| 05/04/2026 | Complete | NELSON & TOM MAINT INC DB | General Wiring |
| 03/04/2026 | Complete | NELSON & TOM MAINT INC DB | General Wiring |
| 03/11/2025 | Complete | RICHARD NEU | — |
| 05/08/2024 | Complete | RICHARD NEU | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/09/2026 | Signed-off | AMC PLBG, HTG & CLNG, INC | Steel |
| Date | Type | Result | Report |
|---|---|---|---|
| 02/24/2026 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 01/28/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 01/27/2026 | Fail-Final PL - Up to 3 Requested Floors | Fail | View ↗ |
| 01/16/2026 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 01/13/2026 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 10/02/2025 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 10/02/2025 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 10/02/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 10/02/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| 09/26/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 09/26/2025 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 09/05/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/02/2026 | Fire-Resistance Rated Construction | Albert Munoz | progress |
| 07/02/2026 | Energy Code Compliance Inspections | Albert Munoz | progress |
| 07/02/2026 | Fenestration air leakage | Albert Munoz | energy_progress |
| 07/02/2026 | Interior lighting power | Albert Munoz | energy_progress |
| 07/02/2026 | Fenestration areas | Albert Munoz | energy_progress |
| 07/02/2026 | Fenestration and door U-factor and product ratings | Albert Munoz | energy_progress |
| 07/02/2026 | Air barrier - visual inspection | Albert Munoz | energy_progress |
| 07/02/2026 | Insulation placement and R values | Albert Munoz | energy_progress |
| 07/02/2026 | Lighting controls | Albert Munoz | energy_progress |
| 07/02/2026 | Lighting in dwelling units | Albert Munoz | energy_progress |
| 07/02/2026 | Fire-Resistant Penetrations and Joints | Albert Munoz | special |
| 07/02/2026 | Structural Stability – Alterations of existing buildings | Albert Munoz | special |
| 06/08/2026 | Fenestration areas | Albert Munoz | energy_progress |
| 06/08/2026 | Fenestration air leakage | Albert Munoz | energy_progress |
| 06/08/2026 | Lighting in dwelling units | Albert Munoz | energy_progress |
| 06/08/2026 | Fire-Resistance Rated Construction | Albert Munoz | progress |
| 06/08/2026 | Energy Code Compliance Inspections | Albert Munoz | progress |
| 06/08/2026 | Interior lighting power | Albert Munoz | energy_progress |
| 06/08/2026 | Lighting controls | Albert Munoz | energy_progress |
| 06/08/2026 | Fire-Resistant Penetrations and Joints | Albert Munoz | special |
| 06/08/2026 | Structural Stability – Alterations of existing buildings | Albert Munoz | special |
| 06/08/2026 | Air barrier - visual inspection | Albert Munoz | energy_progress |
| 06/08/2026 | Insulation placement and R values | Albert Munoz | energy_progress |
| 06/08/2026 | Fenestration and door U-factor and product ratings | Albert Munoz | energy_progress |
| 01/30/2026 | HVAC-R and service water heating system controls | Albert Munoz | energy_progress |