← Back
Two family converted from one family
707 MACON STREET
BROOKLYN · Bedford-Stuyvesant (East) · BIN 3046671
💬 Discuss this project
1899Year Built
2Stories
B3Building Class
R6BZoning
2,600 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · Owner of record: BH 707 MACON LLC · 1,440 sf lot · 1.81 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Floor 24p · 1 filing · 20 docs
Floor 13p · 1 filing · 20 docs
Cellar10p · 1 filing · 20 docs
Basement4p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CUBE BUILDERS GROUP NY103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/07/2025$1.2M—— → —$471/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NIC 88 CORP809/29/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BASIC GROUPS1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CUBE BUILDERS GROUP NYGeneral Contractor603/21/2026
PIPESTYLISTS, INCPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NIC 88 CORP8371609/29/2025
NIC DESIGN INC9758202/12/2025
Building Lifecycle
All (49)Filed (8)Permit Issued (4)Signed Off (2)Violation (1)Inspection (4)Special Inspection (30)
10/02/2025
Signed off — Alteration
INSTALL NEW ELE. H.W.H., BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 3 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01178910-I1
10/01/2025
Signed off — Alteration
INSTALL NEW ELE. H.W.H., BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 3 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01178910-S1
09/30/2025
Special inspection requirement — Fire-Resistance Rated Construction
Eric Sun
09/30/2025
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
09/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
09/30/2025
Special inspection requirement — Air barrier - visual inspection
Eric Sun
09/30/2025
Special inspection requirement — HVAC-R and service water heating equipment
Eric Sun
09/30/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Sun
09/30/2025
Special inspection requirement — Fenestration air leakage
Eric Sun
09/30/2025
Special inspection requirement — Mechanical Systems
Eric Sun
09/30/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Eric Sun
09/30/2025
Special inspection requirement — Maintenance information
Eric Sun
09/30/2025
Special inspection requirement — Final
Eric Sun
09/30/2025
Special inspection requirement — Interior lighting power
Eric Sun
09/30/2025
Special inspection requirement — HVAC-R and service water heating system controls
Eric Sun
09/30/2025
Special inspection requirement — Ventilation and air distribution system
Eric Sun
09/30/2025
Special inspection requirement — Fenestration areas
Eric Sun
09/30/2025
Special inspection requirement — Duct leakage testing, insulation and design
Eric Sun
09/30/2025
Special inspection requirement — Insulation placement and R values
Eric Sun
09/29/2025
Filed — Alteration
INSTALL NEW ELE. H.W.H., BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 3 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01178910-P6
09/29/2025
Filed — Alteration
INSTALL NEW ELE. H.W.H., BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 3 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01178910-P5
09/29/2025
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
09/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
09/26/2025
Special inspection requirement — Fire-Resistance Rated Construction
Eric Sun
09/26/2025
Special inspection requirement — Final
Eric Sun
09/26/2025
Special inspection requirement — Interior lighting power
Eric Sun
09/26/2025
Special inspection requirement — Mechanical Systems
Eric Sun
09/26/2025
Special inspection requirement — Energy Code Compliance Inspections
Eric Sun
09/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
Eric Sun
09/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eric Sun
09/26/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Sun
09/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
Eric Sun
09/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
Eric Sun
09/26/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Eric Sun
07/03/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/03/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/03/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/01/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/12/2025
Filed — Alteration
INSTALL NEW ELE. H.W.H., BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 3 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01178910-P4
06/09/2025
Permit issued — Plumbing
B01178910-S1-PL
05/21/2025
Filed — Alteration
INSTALL NEW ELE. H.W.H., BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 3 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01178910-P2
05/21/2025
Filed — Alteration
INSTALL NEW ELE. H.W.H., BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 3 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01178910-P3
05/06/2025
Filed — Alteration
INSTALL NEW ELE. H.W.H., BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 3 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01178910-P1
04/23/2025
Violation issued (ECB, closed)
Construction
03/21/2025
Permit issued — Mechanical Systems
B01178910-I1-GC-CX
02/13/2025
Permit issued — Plumbing
B01178910-S1-PL
02/13/2025
Permit issued — Mechanical Systems
B01178910-I1-GC-CX
02/12/2025
Filed — Alteration
INSTALL NEW ELE. H.W.H., BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 3 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01178910-I1
02/12/2025
Filed — Alteration
INSTALL NEW ELE. H.W.H., BATHROOM AND KITCHEN FIXTURES IN THE EXISTING 3 STORY BUILDING. PLUMBING WORKS AS PER PLAN. NO CHANGE IN EGRESS, USE, OR OCCUPANCY.
B01178910-S1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offT & T PLUMBING INC06/09/2025
DOB NOWMechanical SystemsSigned-offCUBE BUILDERS GROUP NY03/21/2025
DOB NOWPlumbingSigned-offT & T PLUMBING INC02/13/2025
DOB NOWMechanical SystemsSigned-offCUBE BUILDERS GROUP NY02/13/2025
1 project · most recent 03/05/2025
General Wiring
FiledStatusContractorScope
03/05/2025CompleteJOSEPH WEINSTEIN ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
07/03/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/03/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/03/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/01/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 77
DateRequirementInspectorRole
09/30/2025Mechanical SystemsEric Sunspecial
09/30/2025FinalEric Sunprogress
09/30/2025Fire-Resistance Rated ConstructionEric Sunprogress
09/30/2025Fire-Resistant Penetrations and JointsEric Sunspecial
09/30/2025Energy Code Compliance InspectionsEric Sunprogress
09/30/2025HVAC-R and service water heating equipmentEric Sunenergy_progress
09/30/2025Fenestration and door U-factor and product ratingsEric Sunenergy_progress
09/30/2025Fenestration air leakageEric Sunenergy_progress
09/30/2025Insulation placement and R valuesEric Sunenergy_progress
09/30/2025Air barrier - visual inspectionEric Sunenergy_progress
09/30/2025HVAC-R and service water piping design and insulationEric Sunenergy_progress
09/30/2025HVAC-R and service water heating system controlsEric Sunenergy_progress
09/30/2025Interior lighting powerEric Sunenergy_progress
09/30/2025Maintenance informationEric Sunenergy_progress
09/30/2025Ventilation and air distribution systemEric Sunenergy_progress
09/30/2025Fenestration areasEric Sunenergy_progress
09/30/2025Duct leakage testing, insulation and designEric Sunenergy_progress
09/29/2025Energy Code Compliance InspectionsEric Sunprogress
09/29/2025Fire-Resistant Penetrations and JointsEric Sunspecial
09/26/2025Duct leakage testing, insulation and designEric Sunenergy_progress
09/26/2025HVAC-R and service water heating equipmentEric Sunenergy_progress
09/26/2025HVAC-R and service water heating system controlsEric Sunenergy_progress
09/26/2025HVAC-R and service water piping design and insulationEric Sunenergy_progress
09/26/2025Fire-Resistant Penetrations and JointsEric Sunspecial
09/26/2025Mechanical SystemsEric Sunspecial
Latest 25 of 77.
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/22/2026B01178910-P5Request digital key ↗
08/22/2026B01178910-I1Request digital key ↗
08/22/2026B01178910-P3Request digital key ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications35
▸DOB NOWProgress Inspector Seal & Signature20
09/01/2026B01178910-I1Open ↗
09/01/2026B01178910-I1Open ↗
09/01/2026B01178910-I1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/22/2026B01178910-P5Open ↗
08/22/2026B01178910-P4Open ↗
08/22/2026B01178910-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/01/2026B01178910-I1Open ↗
08/30/2026B01178910-P6Open ↗
08/28/2026B01178910-P4Open ↗
Showing 3 of 7 on file for this type
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/22/2026B01178910-P4Open ↗
08/22/2026B01178910-I1Open ↗
08/22/2026B01178910-P2Open ↗
Showing 3 of 8 on file for this type