HPD08/19/2026§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AND ASSEMBLY AT BUILDING VESTIBULE DOOR AT PUBLIC HALL, 1st STORY
HPD08/19/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HEAVY DUTY LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY
HPD07/09/2026§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. FOR MAY 2026
HPD07/09/2026§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. FOR APRIL 2026
HPD06/28/2026§ 27-2005 HMC: REFIT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY
HPD05/19/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/19/2026§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THEN 10 SQ FEET AT WEST WALL IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/19/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/19/2026567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, GAPS OR CRACKS IN WALLS, CEILINGS, FLOORS, FIXING LEAKS AND MANAGING GARBAGE IN PUBLIC AREAS. EVIDENCE FOUND AT .. IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/19/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOMMUNUCATION SYSTEM FROM BUILDING FRONT TO NORTH WALL PANEL IN THE FOYER LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/19/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE BATHROOM LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/06/2026§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING ROPE AT SOUTH DOOR LEADING TO COURT YARD AT PUBLIC HALL, 1st STORY
HPD05/06/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/27/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/27/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/27/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER COUNTER BALANCE AT WEST 1 AND WEST 2 WINDOWS IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD04/27/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER COUNTER BALANCE AT EAST WINDOW IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD04/27/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOMMUNUCATION SYSTEM FROM BUILDING FRONT TO EAST WALL PANEL IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD04/27/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD04/27/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOMMUNIATION SYSTEM FROM BUILDING FRONT TO EAST WALL PANEL IN THE PRIVATE HALLWAY LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD04/27/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD BASE CABINET FLOOR AT WEST IN THE KITCHEN LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/27/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOMMUNUCATION SYSTEM FROM BUILDING FRONT TO SOUTH WALL PANEL IN THE PRIVATE HALLWAY LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/27/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD04/27/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/22/2026§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF BROKEN SCREW PROTRUDING FROM HANDLE AT BATHTUB IN THE 1st BATHROOM FROM EAST LOCATED AT APT 3D, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD04/15/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
HPD04/15/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOMMUNUCATION SYSTEM FROM BUILDING FRONT TO CELLULAR DEVICE LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
HPD04/15/2026§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. FOR FEBRUARY 2026
HPD04/15/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOMMUNUCATION SYSTEM FROM BUILDING FRONT TO CELLULAR DEVICE LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD03/24/2026§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ROPE PREVENTING DOOR FROM BEING SELF CLOSING AT WEST DOOR LEADING TO COURT YARD AT PUBLIC HALL, 1st STORY
DOB03/24/2026EWO DUE TO CRACKED/SPALLING DECORATIVE MASONRY WITH LOOSE MATERIAL @ 6 & 5FLS OF EXP#1 NORTH. REMEDY: IMMEDIATELY TAKE/PROVIDE ADEQ SAFE MEASURES TO SECURE,PROTECT PUBLIC & INSTALL PUBLIC PROTECTION.REMOVE & SECURE ANY/ALL LOOSE MATERIAL MAKE REPAIRS TO DEFECTIVE FACADE.FILE UNSAFE REPORT FOR U/SUPV OF NYS LIC PROF.FILE UNSAFE REPORT FOR FACADE
ECB03/24/2026FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #1 NORTH (1)CRACKED/SPALLING DECORATIVE MASONRY AT 5TH AND 6TH FLOORS WITH LOOSE MATERIAL ON JULIETTE BALC$5K due
HPD03/10/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD03/10/2026§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. FOR JANUARY 2026
HPD03/10/2026§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. FOR DECEMBER 2025
HPD02/26/2026§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOVE 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD02/26/2026§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOVE 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD02/26/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 6C, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD02/26/2026§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOVE 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD02/26/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 2D, 2nd STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD02/26/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 6A, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD02/08/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD02/08/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD02/08/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD02/08/2026§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOBE 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD02/08/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HYDRONIC BASEBOARD RADIATOR COVER AT SOUTH IN THE 4th ROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD02/08/2026§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HYDRONIC BASEBOARD RADIATOR COVER AT SOUTH IN THE 3rd ROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD02/08/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD02/08/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD02/08/2026§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOVE 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM WEST AT NORTH
HPD02/08/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM WEST AT NORTH
HPD02/08/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD01/10/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 1D, 1st STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD01/10/2026§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER ABOVE 130 DEGREES IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD01/10/2026§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. DATA REQUESTED FOR THE PERIOD OF NOVEMBER 2025
HPD01/10/2026§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 1A, 1st STORY, 3rd APARTMENT FROM EAST AT SOUTH
HPD01/10/2026§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD01/10/2026§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1D, 1st STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD01/10/2026§ 27-2033.3(E) CORRECT FAILURE TO MAINTAIN REQUIRED RECORDS REGARDING INTERNET CAPABLE TEMPERATURE REPORTING DEVICES AND SUBMIT SUCH RECORDS TO THE DEPARTMENT UPON REQUEST. DATA REQUESTED FOR THE PERIOD OF OCTOBER 2025
HPD12/30/2025§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT MISSING LOCATED AT APT 1A, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD12/15/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 25 SQFT AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD12/13/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ.FT. AT CEILING IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD11/30/2025§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 3G, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH
HPD11/30/2025§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD11/15/2025§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD10/17/2025§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 3rd APARTMENT FROM NORTH AT EAST
HPD10/17/2025§27-2033.3(B) CORRECT FAILURE TO INSTALL AN INTERNET CAPABLE TEMPERATURE REPORTING DEVICE IN ONE LIVING ROOM IN APARTMENT ... LOCATED AT APT 5D, 5th STORY, 3rd APARTMENT FROM NORTH AT EAST
HPD10/06/2025§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER DOOR LOCATED AT PUBLIC PARTS, 2nd STORY
HPD10/02/2025§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD10/02/2025§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD08/16/2025§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR LEADING TO SOUTH YARD AT BASEMENT
HPD05/07/2025§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION DOOR IN THE ENTRANCE LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
DOB03/25/2025REMEDY: PROVIDE APPROX 65 LINEAR FEET FOR SIDEWALK SHED.AT EXPOSURE #1 (FRONT OF THE BUILDING)
HPD02/19/2025§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD02/19/2025§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD02/10/2025§ 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD12/12/2024§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD12/12/2024§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD12/05/2024§ 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, GAS RANGE INSTALLED AT BASEMENT
HPD12/05/2024§ 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS AT WASH BASIN, WATER CLOSET, SHOWER STALL AND SINK AT BASEMENT
ECB12/05/2024OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O AND DEPARTMENT OF BUILDINGS RECORDS. ILLEGAL CLASS "A" APARTMENT WITH WASH BASIN, WATER CLOSET,SHOWER STALL AND SINK LOCATED AT BASEMENT. REMEDY: DISCONTINUE ILLEGAL$1K due
HPD07/06/2024§ 27-2005 HMC: REFIT DOOR IN THE ENTRANCE LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
ECB05/02/2024FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #906972. REMEDY: SUBMIT ACCEPTABLE REQU$1K due
DOB05/02/2024FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
ECB03/21/2024OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O AND DEPARTMENT OF BUILDINGS RECORDS. ILLEGAL TWO BEDROOM APARTMENT CREATED AT BASEMENT, WITH WASH BASIN, WATER CLOSET AND SHOWER STALL. REMEDY: DISCONTINUE ILLEGAL U$1K due
HPD03/16/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD10/30/2023§ 27-2081 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS CONSISTING OF RESIDENTIAL SINK, WASH BASIN,WATER CLOSET AND SHOWER STALL INSTALLED AT BASEMENT
HPD10/30/2023§ 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, GAS RANGE AT BASEMENT
ECB09/28/2023AT TIME OF INSPECTION OBSERVED APPROX. 10'-0" LENGTH METAL LINTEL ON 6TH FLOOR INCLUDING EXTERIOR CEMENT STUCCO DISREPAIR CONDITIONS WITH SPALLING, MISSING SECTION OVER CENTER FIRE ESCAPE ON FRONT FACADE EXPO #$625 due
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
HPD05/08/2023§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT FIRE ESCAPE WINDOW RECESS IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH
DOB02/22/2023FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
HPD10/22/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT APT 6F, 6th STORY, 1st APARTMENT FROM WEST AT NORTH
HPD09/22/2021HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
DOB10/14/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/16/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB07/21/202042M5,59BB5:42-M-5=NO DOOR LOCK MONITORING INSTALLED ON THIS CONTROLLERAS MANDATED BY 3.10.12 OF THE APPENDIX K3 OF THE NYCBC. THIS IS A CONTROLLER FEATURE THAT ENSURES PASSENGER SAFETY. REMEDY FILE APPLICATION$6K due
DOB07/31/2018FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018
DOB02/19/2018SIDEWALK SHED CONSTRUCTED UNDE RJOB # 140525634 HAS 2 COLUMNS OUOT OF PLUMB ON THE LEFT SIDE WUTH BENT CROSS MEMBERS