← Back
One story - permanent living quarter
71-51 171 STREET
QUEENS · Pomonok-Electchester-Hillcrest · BIN 4150480
💬 Discuss this project
1955Year Built
1Stories
A2Building Class
R2Zoning
1,372 sfGross Floor Area
1Units
One story - permanent living quarter · 4,331 sf lot · 0.32 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/15/2025$1.4M—Private party → Private party$1,042/sf building
10/07/2016$795K—— → —$579/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC110/10/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYS ESSENTIAL POWER INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854110/10/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
12/08/2025
Signed off — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy
Q01299913-I1
10/15/2025
Permit issued — Solar
Q01299913-I1-SL
10/10/2025
Filed — Alteration
Installation of PV System on existing rooftop. No changes to Egress or use of occupancy
Q01299913-I1
10/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
10/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
10/08/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
10/08/2025
Special inspection requirement — Final
TOM PETERSEN
10/08/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offNYS ESSENTIAL POWER INC10/15/2025
1 project · most recent 10/08/2025
FiledStatusContractorScope
10/08/2025CompleteAMBER ELECTL CONTNG INC—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
10/08/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
10/08/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
10/08/2025Energy Code Compliance InspectionsTOM PETERSENprogress
10/08/2025FinalTOM PETERSENprogress
10/08/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026Q01299913-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/23/2026Q01299913-I1Open ↗
08/23/2026Q01299913-I1Open ↗
08/23/2026Q01299913-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026Q01299913-I1Open ↗
08/23/2026Q01299913-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/18/2026Q01299913-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/18/2026Q01299913-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01299913-I1Open ↗