1 Open Violation ▸FDNY Report ↗
Fire Department · Owner of record: FIRE DEPARTMENT OF NEW YORK · 5,000 sf lot · 2.7 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Roof2p · 1 filing · 7 docs
Floor 32p · 2 filings · 11 docs
Floor 2
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FDNY507/08/2026
FIRE DEPARTMENT OF NEW YORK103/21/2026
NYC FIRE DEPARTMENT103/21/2026
FIRE DEPARTMENT103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KEMS ENGINEERING AND CONSTRUCTION103/25/2025
AYALA ENGINEERING PC111/07/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LEWSAN CONSULTANTS203/21/2026
SUN103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ZHL GROUP INCGeneral Contractor203/21/2026
FRANCO BELLI PLMG&HTG SONPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AYALA ENGINEERING P.C.9207111/07/2024
Building Lifecycle
All (16)Filed (2)Permit Issued (2)Signed Off (1)Violation (3)Inspection (3)Special Inspection (5)
01/02/2026
Signed off — Alteration
B01189478-I1
11/21/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/27/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/13/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
03/28/2025
Permit issued — Plumbing
B01189478-I1-PL
03/25/2025
Filed — Alteration
B01189478-I1
12/03/2024
Permit issued — Mechanical Systems
B01082726-I1-MS
11/07/2024
Filed — Alteration
ALTERATION TYPE 2 APPLICATION FILED FOR INSTALLATION COMMERCIAL KITCHEN HOOD AND FIRE SUPPRESSION SYSTEM. NO CHANGE OF USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01082726-I1
07/18/2024
Special inspection requirement — Mechanical Systems
Pablo Ayala
07/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Pablo Ayala
07/18/2024
Special inspection requirement — Final
Pablo Ayala
07/18/2024
Special inspection requirement — Energy Code Compliance Inspections
Pablo Ayala
07/18/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Pablo Ayala
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offFRANCO BELLI PLMG&HTG SON03/28/2025
DOB NOWMechanical SystemsPermit IssuedZHL GROUP INC12/03/2024
BISEQISSUEDYORK SCAFFOLD EQUIPMENT CORP.02/11/2002
BISEQISSUEDYORK SCAFFOLD EQUIPMENT CORP.01/18/2001
BISEQISSUEDYORK SCAFFOLD EQUIPMENT CORP.01/18/2001
BISEQISSUEDYORK SCAFFOLD EQUIPMENT CORP.01/18/2001
BISEQISSUEDYORK SCAFFOLD EQUIPMENT CORP.01/24/2000
BISEQISSUEDYORK SCAFFOLD EQUIPMENT CORP.12/28/1999
BISEQISSUEDYORK SCAFFOLD EQUIPMENT CORP.02/02/1999
BISEQISSUEDYORK SCAFFOLD EQUIPMENT CORP.05/01/1998
1 project · most recent 11/07/2024
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/07/2024Permit IssuedZHL GROUP INCVentilation Systems
Ventilation
Econ-Air EADU85H 2,800 CFM · Exhaust Fan ×1
1 project · most recent 03/12/2025
FiledStatusContractorScope
03/12/2025CompletePOLARIS ELEC'L CONST CORP—
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
11/21/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/27/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/13/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/18/2024Mechanical SystemsPablo Ayalaspecial
07/18/2024Fire-Resistant Penetrations and JointsPablo Ayalaspecial
07/18/2024FinalPablo Ayalaprogress
07/18/2024Energy Code Compliance InspectionsPablo Ayalaprogress
07/18/2024HVAC-R and service water piping design and insulationPablo Ayalaenergy_progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/23/2026B01082726-I1Request digital key ↗
08/22/2026B01189478-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
01/28/2015321052579Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/22/2026B01189478-I1Open ↗
08/13/2026B01082726-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026B01082726-I1Open ↗
08/23/2026B01082726-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/28/2015321052579Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026B01082726-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/22/2026B01189478-I1Open ↗
08/13/2026B01082726-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
01/28/2015321052579Open ↗
▸Approvals, Objections & Sign-offs2
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter2
08/22/2026B01189478-I1Open ↗
08/13/2026B01082726-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
01/28/2015321052579Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
01/28/2015321052579Open ↗