← Back
Public elementary, junior or senior high
P.S. 312 Bergen Beach
7101 AVENUE T · BIN 3236665
💬 Discuss this project
1966Year Built
3Stories
W1Building Class
R3-1Zoning
192,976 sfGross Floor Area
0Units
LL97 Covered2 Open Violations 1 unresolved · 1 paperwork only ▸FDNY Report ↗
Public elementary, junior or senior high · Owner of record: NYC DEPARTMENT OF EDUCATION · 522,189 sf lot · 0.37 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction104p · 1 filing · 20 docs
Floor 3Under Construction118p · 1 filing · 20 docs
Floor 2Under Construction127p · 2 filings · 20 docs
Floor 1Under Construction117p · 1 filing · 20 docs
CellarUnder Construction112p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NYC SCHOOL CONSTRUCTION AUTHORITY6009/23/2026
NYC DEPARTMENT OF EDUCATION403/22/2026
DOE PS 312 040403/22/2026
DEPARTMENT OF EDUCATION1503/22/2026
DEPT OF EDUCATION P.S.312103/22/2026
DOE P.S.312403/22/2026
DEPT. OF EDUCATION 0103/22/2026
D.O.E. P.S.312 0103/22/2026
P.S.312 BERGEN BEACH D.O.103/22/2026
P.S. 312 D.O.E.503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RKTB ARCHITECTS411/11/2025
360 ENGINEERING P.C.407/03/2024
SHENOY ENGINEERING, P.C.604/11/2024
SALAM & GIACALONE ARCHITECTS PC204/01/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PRECISION 3SIXTY NYC, INC1003/21/2026
ALBERT ARONOV ARCHITECT503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KG CONSTRUCTION SERVICESGeneral Contractor1909/23/2026
AIRTONE CORPGeneral Contractor807/08/2026
MAR-SAL PLBG & HTG, INCPlumbing307/08/2026
EAGLE MECHANICAL INCFire Protection307/08/2026
SKOS CONTRACTING LLCGeneral Contractor207/08/2026
RODEL ELEC'L CONTR'S, INElectrical103/22/2026
CHARAN ELEC'L ENTERP'S INElectrical103/22/2026
GIOVANNI DITURIElectrical103/21/2026
GEMINI ELECTRIC CO., INC.Electrical103/22/2026
JOSEPH LA POINTEElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TWIN PEAKS INC.3171111/11/2025
Building Lifecycle
All (153)Filed (16)Permit Issued (27)Signed Off (3)Violation (60)Objection (17)Special Inspection (30)
09/22/2026
Permit issued — General Construction
B00706672-I1-GC
03/18/2026
Violation issued (FDNY_ORDER, closed)
03/18/2026
Violation issued (FDNY_ORDER, closed)
03/18/2026
Violation issued (FDNY_ORDER, closed)
03/18/2026
Violation issued (FDNY_ORDER, closed)
03/18/2026
Violation issued (FDNY_ORDER, closed)
03/18/2026
Violation issued (FDNY_ORDER, closed)
03/18/2026
Violation issued (FDNY_ORDER, closed)
03/18/2026
Violation issued (FDNY_ORDER, closed)
01/06/2026
Permit issued — Sprinklers
B00706672-S5-EW-SP
01/05/2026
Permit issued — Plumbing
B00706672-S2-PL
12/04/2025
Violation issued (FDNY_NOV, closed)
11/19/2025
Objection raised — Other
11/17/2025
Permit issued — General Construction
B00959236-I1-GC
11/17/2025
Permit issued — General Construction
B00959236-S2-GC
11/11/2025
Filed — Alteration
MECHANICAL WORK RELATED TO PROGRAMM ACCESSIBILITY PROJECT
B00706672-P1
11/11/2025
Special inspection requirement — Maintenance information
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Energy Code Compliance Inspections
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Insulation placement and R values
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Post-installed Anchors
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Interior lighting power
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Sprayed fire-resistant materials
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Fenestration air leakage
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Electrical motors and elevators
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Masonry
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Air barrier - visual inspection
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Fire-Resistance Rated Construction
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Lighting controls
MIKHAIL ZEYGMAN
11/11/2025
Special inspection requirement — Concrete - Cast-In-Place
MIKHAIL ZEYGMAN
10/15/2025
Permit issued — Structural
B00706672-S4-ST
10/15/2025
Permit issued — General Construction
B00706672-I1-GC
10/14/2025
Signed off — Alteration
INSTALLATION OF SUPPORTED SCAFFOLD FOR WORK LOCATIONS ACCESS
B00941443-I1
10/14/2025
Signed off — Alteration
INSTALLATION OF SIDEWALK SHED FOR PUBLIC PROTECTION DURING CONSTRUCTION WORK
B00941469-I1
10/14/2025
Signed off — Alteration
INSTALLATION OF CONSTRUCTION FENCE FOR PUBLIC PROTECTION FROM AREAS OF CONSTRUCTION WORK
B00941456-I1
09/10/2025
Permit issued — Mechanical Systems
B00706672-S1-MS
07/21/2025
Permit issued — Mechanical Systems
B00706672-S1-MS
03/27/2025
Violation issued (ECB, closed)
Construction
01/03/2025
Violation issued (FDNY_NOV, closed)
12/13/2024
Permit issued — Plumbing
B00706672-S2-PL
12/13/2024
Permit issued — Sprinklers
B00706672-S5-EW-SP
11/13/2024
Permit issued — Sidewalk Shed
B00941469-I1-SH
11/12/2024
Permit issued — Structural
B00706672-S4-ST
11/12/2024
Permit issued — General Construction
B00706672-I1-GC
11/12/2024
Permit issued — Supported Scaffold
B00941443-I1-SF
11/12/2024
Permit issued — Construction Fence
B00941456-I1-FN
10/10/2024
Permit issued — Mechanical Systems
B00706672-S1-MS
09/04/2024
Permit issued — Foundation
B00706672-S6-FO
07/03/2024
Filed — Alteration
INSTALLATION OF CONSTRUCTION FENCE FOR PUBLIC PROTECTION FROM AREAS OF CONSTRUCTION WORK
B00941456-P1
05/01/2024
Violation issued (ECB, closed)
Construction
05/01/2024
Violation issued (ECB, closed)
Construction
04/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAXIM KORNGOLD
04/18/2024
Special inspection requirement — Energy Code Compliance Inspections
MAXIM KORNGOLD
04/18/2024
Special inspection requirement — Fire-Resistance Rated Construction
MAXIM KORNGOLD
04/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
MAXIM KORNGOLD
04/18/2024
Special inspection requirement — Lighting controls
MAXIM KORNGOLD
04/18/2024
Special inspection requirement — Post-installed Anchors
MAXIM KORNGOLD
04/18/2024
Special inspection requirement — Interior lighting power
MAXIM KORNGOLD
Latest 60 of 153 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedKG CONSTRUCTION SERVICES09/22/2026
DOB NOWSprinklersPermit IssuedEAGLE MECHANICAL INC01/06/2026
DOB NOWPlumbingPermit IssuedMAR-SAL PLBG & HTG, INC01/05/2026
DOB NOWGeneral ConstructionPermit IssuedSKOS CONTRACTING LLC11/17/2025
DOB NOWGeneral ConstructionPermit IssuedSKOS CONTRACTING LLC11/17/2025
DOB NOWStructuralPermit IssuedSTALCO10/15/2025
DOB NOWGeneral ConstructionPermit IssuedSTALCO10/15/2025
DOB NOWMechanical SystemsPermit IssuedAIRTONE CORP09/10/2025
DOB NOWMechanical SystemsPermit IssuedAIRTONE CORP07/21/2025
DOB NOWPlumbingPermit IssuedMAR-SAL PLBG & HTG, INC12/13/2024
DOB NOWSprinklersPermit IssuedEAGLE MECHANICAL INC12/13/2024
DOB NOWSidewalk ShedSigned-offSTALCO11/13/2024
DOB NOWStructuralPermit IssuedSTALCO11/12/2024
DOB NOWGeneral ConstructionPermit IssuedSTALCO11/12/2024
DOB NOWSupported ScaffoldSigned-offSTALCO11/12/2024
DOB NOWConstruction FenceSigned-offSTALCO11/12/2024
DOB NOWMechanical SystemsPermit IssuedAIRTONE CORP10/10/2024
DOB NOWFoundationPermit IssuedSTALCO09/04/2024
DOB NOWFoundationPermit IssuedSTALCO02/26/2024
DOB NOWSprinklersPermit IssuedEAGLE MECHANICAL INC02/21/2024
DOB NOWPlumbingPermit IssuedMAR-SAL PLBG & HTG, INC12/06/2023
DOB NOWGeneral ConstructionPermit IssuedSTALCO12/04/2023
DOB NOWStructuralPermit IssuedSTALCO12/04/2023
DOB NOWMechanical SystemsPermit IssuedAIRTONE CORP12/04/2023
DOB NOWSidewalk ShedSigned-offSTALCO11/22/2023
DOB NOWSupported ScaffoldSigned-offSTALCO11/17/2023
DOB NOWConstruction FenceSigned-offSTALCO11/17/2023
BISPLISSUEDMAR-SAL PLBG & HTG, INC07/07/2025
BISPLISSUEDMAR-SAL PLBG & HTG, INC07/07/2025
BISOTISSUEDSKY HEIGHTS CONSTRUCTION07/07/2025
BISOTISSUEDSKY HEIGHTS CONSTRUCTION09/10/2024
BISMHISSUEDTHERMO TECH MECHANICAL I*03/15/2024
BISPLISSUEDMAR-SAL PLBG & HTG, INC03/05/2024
BISPLISSUEDMAR-SAL PLBG & HTG, INC03/05/2024
BISOTISSUEDSKY HEIGHTS CONSTRUCTION10/24/2023
BISOTISSUEDSKY HEIGHTS CONSTRUCTION02/15/2023
BISPLISSUEDMAR-SAL PLBG & HTG, INC02/10/2023
BISPLISSUEDMAR-SAL PLBG & HTG, INC02/10/2023
BISMHISSUEDTHERMO TECH MECHANICAL I*02/09/2023
BISEQISSUEDSKY HEIGHTS CONSTRUCTION02/09/2023
+ 37 more permits on file
1 project · most recent 11/11/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/11/2025Permit IssuedKG CONSTRUCTION SERVICESHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PKA-A36KA6 920 CFM · Vrf Indoor ×1
PUZ-HA36NHA5 920 CFM · Heat Pump Outdoor ×1
Ventilation
Greenheck GB-098-4 525 CFM · Exhaust Fan ×2
GB-100-3 900 CFM · Exhaust Fan ×2
GB-160-7 1,950 CFM · Exhaust Fan ×1
1 project · most recent 04/11/2024
Water/Sanitary
FiledStatusContractorScope
04/11/2024——Water/Sanitary
15 projects · most recent 07/27/2026
General Wiring Lighting
FiledStatusContractorScope
07/27/2026Permit IssuedINLIGHT ELECTRICAL CORPGeneral Wiring
06/23/2026CompleteSTATIC ELECTRIC CORPGeneral Wiring
05/14/2026CompleteVIAL ELECTRIC & COMPANYLighting
11/21/2025Permit IssuedALL BORO ELECTRIC CORPGeneral Wiring
11/21/2023Permit IssuedRODEL ELEC'L CONTR'S, IN—
11/21/2023CompleteRODEL ELEC'L CONTR'S, IN—
11/14/2023Permit IssuedA & S ELECTRIC INC.General Wiring
04/14/2023CompleteGEMINI ELECTRIC CO., INC.—
08/23/2022CompleteGEMINI ELECTRIC CO., INC.—
07/07/2022CompleteMNBC ELECTRICAL CORPGeneral Wiring
11/04/2020CompleteCHARAN ELEC'L ENTERP'S INGeneral Wiring
12/24/2019CompleteCHARAN ELEC'L ENTERP'S IN—
01/22/2019CompleteCHARAN ELEC'L ENTERP'S INGeneral Wiring
02/02/2018CompleteLABCO ELETRT CONTNG CORPGeneral Wiring
12/26/2017CompleteANCO ELECTL CONTCTNG INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 81
DateRequirementInspectorRole
11/11/2025Structural Stability – Alterations of existing buildingsMIKHAIL ZEYGMANspecial
11/11/2025Sprayed fire-resistant materialsMIKHAIL ZEYGMANspecial
11/11/2025Post-installed AnchorsMIKHAIL ZEYGMANspecial
11/11/2025MasonryMIKHAIL ZEYGMANspecial
11/11/2025Fire-Resistant Penetrations and JointsMIKHAIL ZEYGMANspecial
11/11/2025Concrete - Cast-In-PlaceMIKHAIL ZEYGMANspecial
11/11/2025Lighting controlsMIKHAIL ZEYGMANenergy_progress
11/11/2025Insulation placement and R valuesMIKHAIL ZEYGMANenergy_progress
11/11/2025Maintenance informationMIKHAIL ZEYGMANenergy_progress
11/11/2025Electrical motors and elevatorsMIKHAIL ZEYGMANenergy_progress
11/11/2025Fenestration air leakageMIKHAIL ZEYGMANenergy_progress
11/11/2025Fenestration and door U-factor and product ratingsMIKHAIL ZEYGMANenergy_progress
11/11/2025Air barrier - visual inspectionMIKHAIL ZEYGMANenergy_progress
11/11/2025Fire-Resistance Rated ConstructionMIKHAIL ZEYGMANprogress
11/11/2025Energy Code Compliance InspectionsMIKHAIL ZEYGMANprogress
11/11/2025Interior lighting powerMIKHAIL ZEYGMANenergy_progress
04/18/2024Fire-Resistant Penetrations and JointsMAXIM KORNGOLDspecial
04/18/2024Energy Code Compliance InspectionsMAXIM KORNGOLDprogress
04/18/2024Fire-Resistance Rated ConstructionMAXIM KORNGOLDprogress
04/18/2024Interior lighting powerMAXIM KORNGOLDenergy_progress
04/18/2024Lighting controlsMAXIM KORNGOLDenergy_progress
04/18/2024Fire-Resistant Penetrations and JointsMAXIM KORNGOLDspecial
04/18/2024Post-installed AnchorsMAXIM KORNGOLDspecial
03/28/2024Fire-Resistant Penetrations and Joints—special
03/28/2024Fire-Resistant Penetrations and Joints—special
Latest 25 of 81.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Ps312kEducation—
Project B00941443 Alteration · LOC Issued · 10/11/2023
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 184 on file (BIS + DOB NOW)
▸Plans & Drawings16
▸DOB NOWPlans/Sketch16
08/28/2026B00706672-S6Request digital key ↗
08/28/2026B00706672-P1Request digital key ↗
08/28/2026B00706672-S2Request digital key ↗
Showing 3 of 16 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
07/17/2019340686804Open ↗
01/27/2014320862241Open ↗
▸Seals & Professional Certifications91
▸DOB NOWProgress Inspector Seal & Signature42
09/02/2026B00959236-I1Open ↗
08/31/2026B00706672-P1Open ↗
08/31/2026B00706672-P1Open ↗
Showing 3 of 42 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature29
09/02/2026B00959236-I1Open ↗
08/31/2026B00706672-P1Open ↗
08/31/2026B00706672-P1Open ↗
Showing 3 of 29 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature16
08/28/2026B00706672-S6Open ↗
08/28/2026B00706672-S5Open ↗
08/28/2026B00706672-P1Open ↗
Showing 3 of 16 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
07/17/2019340686804Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/17/2019340686804Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/17/2019340686804Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/27/2014320862241Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
01/27/2014320862241Open ↗
▸Safety & Tenant Protection4
▸DOB NOWNYCSCA - Approved Site Safety Plans4
08/13/2026B00941456-P1Open ↗
08/13/2026B00941456-I1Open ↗
08/13/2026B00941469-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos1
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
01/27/2014320862241Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/17/2019340686804Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
01/27/2014320862241Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
07/17/2019340686804Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/17/2019340686804Open ↗
▸Approvals, Objections & Sign-offs43
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter16
08/25/2026B00959236-S2Open ↗
08/25/2026B00959236-I1Open ↗
08/13/2026B00941456-I1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)16
08/25/2026B00959236-I1Open ↗
08/25/2026B00959236-S2Open ↗
08/13/2026B00959236-P1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWDEP Variance (V5) letter8
08/13/2026B00959236-S2Open ↗
08/13/2026B00706672-I1Open ↗
08/13/2026B00706672-S1Open ↗
Showing 3 of 8 on file for this type
▸BISDESIGN COMM. APPROVAL: CITY-OWNED PROPERTY (EXTERIOR WORK)1
07/17/2019340686804Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
01/27/2014320862241Open ↗
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)1
08/13/2026B00706672-S2Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
07/17/2019340686804Open ↗
01/27/2014320862241Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
01/27/2014320862241Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
07/17/2019340686804Open ↗
▸Other Documents18
▸DOB NOWNYCSCA - BCC Plan Examination Transmittal16
08/25/2026B00959236-S2Open ↗
08/25/2026B00959236-I1Open ↗
08/13/2026B00706672-S5Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWPlot Diagram1
08/13/2026B00706672-S6Open ↗
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/13/2026B00706672-S4Open ↗