← Back
Three families
711 EAST 215 STREET
BRONX · Williamsbridge-Olinville · BIN 2112900
💬 Discuss this project
2004Year Built
3Stories
C0Building Class
R7AZoning
3,723 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Three families · Owner of record: 711 EAST 215 LLC · 2,531 sf lot · 1.47 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction60p · 1 filing · 20 docs
Floor 3Under Construction59p · 1 filing · 20 docs
Floor 2Under Construction60p · 1 filing · 20 docs
Floor 1Under Construction64p · 1 filing · 20 docs
Site & exteriorUnder Construction31p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
711 EAST 2151507/01/2026
WESTORCHARD MANAGEMENT1004/09/2026
DARECO HOLDING303/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/16/2024$975K—Private party → 711 EAST 215 LLC$262/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PRAMODRAY SHAH, P.E.105/21/2026
ADB ASSOCIATES812/29/2025
VASILIOS ARTEMIOU PE209/20/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC DESIGN FILE1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MABE GROUP INCGeneral Contractor1207/01/2026
POWER DIRECT ELECTRIC INCElectrical103/22/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN8524105/21/2026
HRF SERVICES CORP5616912/29/2025
Building Lifecycle
All (84)Filed (11)Permit Issued (5)Signed Off (3)Violation (20)Inspection (11)Objection (4)Special Inspection (30)
06/29/2026
Permit issued — Structural
X01023872-S4-ST
05/21/2026
Filed — Alteration CO
Existing 3 story, 3-Family to be converted into a 10-unit building
X01023872-S4
05/14/2026
Special inspection requirement — Final
Shahrish Shuvo
05/14/2026
Special inspection requirement — Structural Cold-Formed Steel
Shahrish Shuvo
05/14/2026
Special inspection requirement — Masonry
Shahrish Shuvo
05/14/2026
Special inspection requirement — Structural Steel - Details
Shahrish Shuvo
05/14/2026
Special inspection requirement — Structural Wood Frame
Shahrish Shuvo
05/14/2026
Special inspection requirement — Wood – Prefabricated I-Joists
Shahrish Shuvo
05/14/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
03/04/2026
Violation issued (HPD, closed)
C
03/04/2026
Violation issued (HPD, closed)
C
03/04/2026
Violation issued (HPD, closed)
C
02/13/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/27/2026
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
01/12/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
FAHAD FATEH
01/12/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
01/12/2026
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
01/12/2026
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
01/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
01/12/2026
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
01/12/2026
Special inspection requirement — Fenestration areas
FAHAD FATEH
01/12/2026
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
01/12/2026
Special inspection requirement — Permanent certificate
FAHAD FATEH
01/12/2026
Special inspection requirement — Maintenance information
FAHAD FATEH
01/12/2026
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
01/12/2026
Special inspection requirement — Metering
FAHAD FATEH
01/12/2026
Special inspection requirement — Interior lighting power
FAHAD FATEH
12/29/2025
Filed — Alteration CO
Existing 3 story, 3-Family to be converted into a 10-unit building
X01023872-P8
12/26/2025
Special inspection requirement — Maintenance information
FAHAD FATEH
12/26/2025
Special inspection requirement — Metering
FAHAD FATEH
12/26/2025
Special inspection requirement — Fenestration areas
FAHAD FATEH
12/26/2025
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
12/26/2025
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
12/26/2025
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
12/26/2025
Special inspection requirement — Permanent certificate
FAHAD FATEH
12/26/2025
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
FAHAD FATEH
12/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
12/26/2025
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
12/24/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/25/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/21/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
11/18/2025
Violation issued (HPD, closed)
I
11/10/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/10/2025
Filed — Alteration CO
Existing 3 story, 3-Family to be converted into a 10-unit building
X01023872-P7
06/13/2025
Violation issued (HPD, closed)
A
05/28/2025
Signed off — Alteration CO
Existing 3 story, 3-Family to be converted into a 10-unit building
X01023872-S3
05/28/2025
Signed off — Alteration CO
Existing 3 story, 3-Family to be converted into a 10-unit building
X01023872-S1
05/28/2025
Signed off — Alteration CO
Existing 3 story, 3-Family to be converted into a 10-unit building
X01023872-S2
11/25/2024
Violation issued (HPD, closed)
I
11/21/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/18/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/23/2024
Filed — Alteration CO
Existing 3 story, 3-Family to be converted into a 10-unit building
X01023872-P5
09/20/2024
Filed — Alteration CO
Existing 3 story, 3-Family to be converted into a 10-unit building
X01023872-P2
09/20/2024
Filed — Alteration CO
Existing 3 story, 3-Family to be converted into a 10-unit building
X01023872-P3
08/28/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/20/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/15/2024
Permit issued — Sprinklers
X01023872-S3-EW-SP
08/15/2024
Permit issued — Plumbing
X01023872-S1-PL
08/01/2024
Permit issued — Mechanical Systems
X01023872-S2-MS
07/29/2024
Permit issued — General Construction
X01023872-I1-GC
Latest 60 of 84 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedMABE GROUP INC06/29/2026
DOB NOWSprinklersSigned-offA M B MECHANICAL INC08/15/2024
DOB NOWPlumbingSigned-offPRIME PIPING & HEATING IN08/15/2024
DOB NOWMechanical SystemsSigned-offAB BUILDERS NY08/01/2024
DOB NOWGeneral ConstructionPermit IssuedAB BUILDERS NY07/29/2024
BISPLISSUEDVITELLO P & MECHANICAL INC01/05/2005
1 project · most recent 05/21/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/21/2026Permit IssuedAB BUILDERS NYHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Daikin RXS12LVJU 108,000 BTU · Heat Pump Outdoor ×9
2MXS18NMVJUA 18,000 BTU · Heat Pump Outdoor ×1
Ventilation
Nutone AEN110 110 CFM · Exhaust Fan ×10
QTXEN150 150 CFM · Kitchen Exhaust ×10
1 project · most recent 05/21/2026
Sprinkler System
FiledStatusContractorScope
05/21/2026Signed-offPRIME PIPING & HEATING INSprinkler System
1 project · most recent 05/21/2026
Water/Sanitary
FiledStatusContractorScope
05/21/2026Signed-offA M B MECHANICAL INCWater/Sanitary
2 projects · most recent 04/21/2025
General Wiring
FiledStatusContractorScope
04/21/2025CompletePOWER DIRECT ELECTRIC INC—
08/01/2024CompletePOWER DIRECT ELECTRIC INCGeneral Wiring
1 project · most recent 05/21/2026
Steel Masonry Wood
FiledStatusContractorScope
05/21/2026Permit IssuedAB BUILDERS NYSteel, Masonry, Wood
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
02/13/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/27/2026Fail-Final CND-Occupancy InspectionFailView ↗
12/24/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/25/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/21/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/10/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/21/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/18/2024Pass-Final CND-Occupancy InspectionPassView ↗
08/28/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/20/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
04/07/2023Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 101
DateRequirementInspectorRole
05/14/2026MasonryShahrish Shuvospecial
05/14/2026Structural Cold-Formed SteelShahrish Shuvospecial
05/14/2026Structural Steel - DetailsShahrish Shuvospecial
05/14/2026Wood – Prefabricated I-JoistsShahrish Shuvospecial
05/14/2026Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
05/14/2026Structural Wood FrameShahrish Shuvoprogress
05/14/2026FinalShahrish Shuvoprogress
01/12/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
01/12/2026Exterior Insulation and Finish Systems (EIFS)FAHAD FATEHspecial
01/12/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
01/12/2026Fire-Resistance Rated ConstructionFAHAD FATEHprogress
01/12/2026Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
01/12/2026Air barrier - visual inspectionFAHAD FATEHenergy_progress
01/12/2026MeteringFAHAD FATEHenergy_progress
01/12/2026Fenestration areasFAHAD FATEHenergy_progress
01/12/2026Maintenance informationFAHAD FATEHenergy_progress
01/12/2026Permanent certificateFAHAD FATEHenergy_progress
01/12/2026Fenestration air leakageFAHAD FATEHenergy_progress
01/12/2026Insulation placement and R valuesFAHAD FATEHenergy_progress
01/12/2026Interior lighting powerFAHAD FATEHenergy_progress
12/26/2025Interior lighting powerFAHAD FATEHenergy_progress
12/26/2025Exterior Insulation and Finish Systems (EIFS)FAHAD FATEHspecial
12/26/2025Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
12/26/2025Energy Code Compliance InspectionsFAHAD FATEHprogress
12/26/2025Fire-Resistance Rated ConstructionFAHAD FATEHprogress
Latest 25 of 101.
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/16/2026X01023872-P5Request digital key ↗
08/16/2026X01023872-P8Request digital key ↗
08/16/2026X01023872-P2Request digital key ↗
Showing 3 of 11 on file for this type
▸Seals & Professional Certifications39
▸DOB NOWProgress Inspector Seal & Signature15
08/31/2026X01023872-P7Open ↗
08/31/2026X01023872-P7Open ↗
08/28/2026X01023872-P3Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
08/31/2026X01023872-P7Open ↗
08/31/2026X01023872-P7Open ↗
08/28/2026X01023872-P3Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/16/2026X01023872-P8Open ↗
08/16/2026X01023872-P2Open ↗
08/16/2026X01023872-P1Open ↗
Showing 3 of 11 on file for this type
▸Other Documents5
▸DOB NOWProperty Ownership Certification5
08/16/2026X01023872-P3Open ↗
08/16/2026X01023872-I1Open ↗
08/16/2026X01023872-P8Open ↗
Showing 3 of 5 on file for this type