| Owner | Filings | Most Recent |
|---|---|---|
| OWNER'S REP | 7 | 03/22/2026 |
| 712 EAST 216 LLC | 2 | 03/22/2026 |
| SKYWARD DEVELOPERS | 6 | 03/22/2026 |
| EM TEE CAPITAL | 1 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 05/03/2017 | $940K | — | — → — | $95/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| NIKOLAI KATZ ARCHITECT | 10 | 05/26/2026 |
| CHOSEN MEP, CORP. | 4 | 05/13/2024 |
| FL&M ENGINEERING DESIGN &INSPECTION | 1 | 05/17/2023 |
| SH ENGINEERING PLLC | 10 | 03/27/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| EXPRESS FILING INC | 44 | 03/21/2026 |
| ADVANCED BUILDERS SERVICES | 1 | 03/21/2026 |
| GREEN STUDIO | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| SKYWARD DEVELOPERS INC | General Contractor | 21 | 07/08/2026 |
| MANHATTAN D ENTERPRISES | General Contractor | 6 | 03/21/2026 |
| MPI PLUMBING CORP | Plumbing | 2 | 07/08/2026 |
| MOD CONSULTANTS LLC | General Contractor | 2 | 07/08/2026 |
| M.R. ELEC'L SERVICE LLC | Electrical | 1 | 03/22/2026 |
| PRIME PIPING & HEATING IN | Fire Protection | 1 | 07/08/2026 |
| B&B MECH PLBG & HTG LLC | Plumbing | 1 | 07/08/2026 |
| TARGET PIPING NY LLC | Fire Protection | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| HRF SERVICES CORP | 5616 | 21 | 05/26/2026 |
| MJ ENGINEERING & DESIGN | 5546 | 1 | 05/17/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | MOD CONSULTANTS LLC | 04/28/2026 |
| DOB NOW | Sprinklers | Permit Issued | TARGET PIPING NY LLC | 09/15/2025 |
| DOB NOW | Mechanical Systems | Signed-off | MOD CONSULTANTS LLC | 02/05/2025 |
| DOB NOW | Sprinklers | Permit Issued | TARGET PIPING NY LLC | 02/04/2025 |
| DOB NOW | Sprinklers | Permit Issued | YG SERVICES INC | 06/27/2024 |
| DOB NOW | Structural | Signed-off | SKYWARD DEVELOPERS INC | 07/24/2023 |
| DOB NOW | Construction Fence | Signed-off | SKYWARD DEVELOPERS INC | 07/20/2023 |
| DOB NOW | General Construction | Permit Issued | SKYWARD DEVELOPERS INC | 07/20/2023 |
| DOB NOW | General Construction | Permit Issued | SKYWARD DEVELOPERS INC | 07/19/2023 |
| DOB NOW | Supported Scaffold | Signed-off | MANHATTAN D ENTERPRISES | 07/08/2023 |
| DOB NOW | Supported Scaffold | Signed-off | MANHATTAN D ENTERPRISES | 07/08/2023 |
| DOB NOW | Sprinklers | Permit Issued | A M B MECHANICAL INC | 06/15/2023 |
| DOB NOW | General Construction | Permit Issued | SKYWARD DEVELOPERS INC | 02/24/2023 |
| DOB NOW | Plumbing | Permit Issued | YG SERVICES INC | 01/23/2023 |
| DOB NOW | Construction Fence | Signed-off | SKYWARD DEVELOPERS INC | 09/20/2022 |
| DOB NOW | Foundation | Permit Issued | SKYWARD DEVELOPERS INC | 09/15/2022 |
| DOB NOW | General Construction | Permit Issued | SKYWARD DEVELOPERS INC | 09/13/2022 |
| DOB NOW | Support of Excavation | Signed-off | SKYWARD DEVELOPERS INC | 09/13/2022 |
| DOB NOW | Structural | Signed-off | SKYWARD DEVELOPERS INC | 09/12/2022 |
| DOB NOW | Foundation | Signed-off | SKYWARD DEVELOPERS INC | 05/23/2022 |
| BIS | OT | ISSUED | SAME | 08/26/1994 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/26/2026 | Permit Issued | MOD CONSULTANTS LLC | Heating Systems, Ventilation Systems | Heating Daikin RX12BXVJU 14,400 BTU · Condensing Unit ×24 2MXS18WMVJU9 18,900 BTU · Condensing Unit ×5 3MXS24WMVJU9 24,000 BTU · Condensing Unit ×1 RX09AXVJU 9,000 BTU · Condensing Unit ×1 Ventilation Whisper Warm FV-11VH1 50 CFM · Exhaust Fan ×30 Zephyr Z5H 50 CFM · Kitchen Exhaust ×28 Greenheck G-067-VG 200 CFM · Exhaust Fan ×2 G-079-VG 600 CFM · Exhaust Fan ×2 AS-14-440-A5X-QD 550 CFM · Exhaust Fan ×1 G-1/80 600 CFM · Exhaust Fan ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/26/2026 | Permit Issued | TARGET PIPING NY LLC | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/26/2026 | Permit Issued | TARGET PIPING NY LLC | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 03/24/2025 | Complete | M.R. ELEC'L SERVICE LLC | General Wiring |
| 05/19/2023 | Permit Issued | SOLAS ELECTRICAL CORP | — |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/26/2026 | Permit Issued | MOD CONSULTANTS LLC | Masonry |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/19/2026 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 02/13/2026 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 01/06/2026 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 11/25/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 11/05/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/22/2025 | No Access-Final CND-Occupancy Inspection | No Access | View ↗ |
| 10/08/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 10/03/2025 | Certified Medical Gas - MG - PL - Roughing | Certified | View ↗ |
| 10/03/2025 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 08/19/2025 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 03/15/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 01/16/2024 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 01/11/2024 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 07/06/2023 | Pass-Final PL - Up to 9 Requested Floors | Pass | View ↗ |
| 03/30/2023 | Pass-Final PL - Underground | Pass | View ↗ |
| 03/24/2023 | Pass-Final PL - Underground | Pass | View ↗ |
| 09/30/2022 | Certified Storm Drainage-ST-Piping-Roughing | Certified | View ↗ |
| 09/30/2022 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 09/30/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 06/02/2026 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 06/02/2026 | Lighting controls | FAHAD FATEH | energy_progress |
| 06/02/2026 | Lighting in dwelling units | FAHAD FATEH | energy_progress |
| 06/02/2026 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 06/02/2026 | Metering | FAHAD FATEH | energy_progress |
| 06/02/2026 | Fenestration and door U-factor and product ratings | FAHAD FATEH | energy_progress |
| 06/02/2026 | Interior lighting power | FAHAD FATEH | energy_progress |
| 06/02/2026 | Masonry | FAHAD FATEH | special |
| 06/02/2026 | Structural Stability – Alterations of existing buildings | FAHAD FATEH | special |
| 06/02/2026 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 06/02/2026 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 06/02/2026 | Fire-Resistance Rated Construction | FAHAD FATEH | progress |
| 06/02/2026 | Fenestration areas | FAHAD FATEH | energy_progress |
| 06/02/2026 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 06/02/2026 | Maintenance information | FAHAD FATEH | energy_progress |
| 04/28/2026 | Masonry | FAHAD FATEH | special |
| 04/28/2026 | Fenestration areas | FAHAD FATEH | energy_progress |
| 04/28/2026 | Fenestration and door U-factor and product ratings | FAHAD FATEH | energy_progress |
| 04/28/2026 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 04/28/2026 | Lighting in dwelling units | FAHAD FATEH | energy_progress |
| 04/28/2026 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 04/28/2026 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 04/28/2026 | Interior lighting power | FAHAD FATEH | energy_progress |
| 04/28/2026 | Metering | FAHAD FATEH | energy_progress |
| 04/28/2026 | Maintenance information | FAHAD FATEH | energy_progress |