← Back
Elevator apt, fireproof with stores
713 2 AVENUE
MANHATTAN · Murray Hill-Kips Bay · BIN 1020359
💬 Discuss this project
1955Year Built
13Stories
D6Building Class
C1-9Zoning
111,570 sfGross Floor Area
175Units
LL97 CoveredRent Stabilized2 Open Violations ▸FISP: SAFE
Elevator apt, fireproof with stores · Owner of record: TIMSTON CORP · 13,510 sf lot · 8.26 FAR built · Flood zone X
Locations of Work
Architecture
Floor 11p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ELYACHAR PROPERTIES2807/08/2026
E-Z PERMIT NY, LLC503/22/2026
TIMSTON4803/22/2026
ALTEK CONSTRUCTION303/22/2026
TINSTON CORP103/22/2026
HPD 806103/22/2026
RURADAN103/22/2026
PRIME REALTY SERVICE203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
YOU GAO102/20/2025
HOWARD L ZIMMERMAN ARCH & ENG DPC207/08/2022
ENTHINK ENGINEERS LLC101/20/2022
SUNG HO SHIN ARCHITECT, PC312/16/2021
MDALTON LLC202/05/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
INDESIGN STUDIO203/21/2026
HLZAE203/21/2026
MUNICIPAL EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EXO INDUSTRIES CORPGeneral Contractor603/21/2026
ECOTECH MACHINERY LLCGeneral Contractor407/08/2026
VAN VASSELLElectrical203/21/2026
ONCIOIU, DUMITRUElectrical103/21/2026
OUTFRONT MEDIA LLCElectrical103/21/2026
PK ELECTRIC INCElectrical103/22/2026
ABR PLBG & HTG CONTR. INCFire Protection107/08/2026
ABR PLBG&HTG CONTR INCPlumbing107/08/2026
WASOFF PLBG & UTILITY COPlumbing107/08/2026
BEARD, JOIElectrical103/21/2026
NEPTUNE SIGNS AWNINGSScaffold107/08/2026
BENNETT, AARONElectrical103/21/2026
FABCON PRECAST LLCElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
YOU GAO9407102/20/2025
HOWARD L ZIMMERMAN ARCHIT1712207/08/2022
SUNG HO SHIN ARCHITECT2997312/16/2021
ALAN MARGOLIN & ASSOC423202/05/2021
Building Lifecycle
All (124)Filed (9)Permit Issued (8)Signed Off (2)Facade (FISP) (16)Violation (60)Inspection (9)Objection (4)Special Inspection (16)
03/29/2025
Violation issued (HPD, closed)
C
02/25/2025
Permit issued — Sign
M01182183-I1-SG
02/20/2025
Filed — Alteration
ERECT AN ILLUMINATED SIGN ON WALL.NOT WITHIN VIEW OF ARTERIAL HIGHWAY OR PUBLIC PARK 1/2 ACRE OR MORE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01182183-I1
02/17/2025
Special inspection requirement — Final
You Gao
02/17/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
You Gao
01/05/2024
Violation issued (ECB, closed)
Construction
10/30/2023
Violation issued (HPD, closed)
C
08/23/2023
Violation issued (HPD, closed)
C
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/09/2023
Signed off — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00663194-I1
11/28/2022
Cycle 9 facade report signed — SAFE
11/11/2022
Cycle 9 facade report submitted
10/24/2022
Signed off — Alteration
FISP REPAIRS TO INCLUDE MASONRY REPLACEMENT AND CRACK REPAIRS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00523563-I1
10/11/2022
Cycle 9 facade inspection completed
07/25/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/22/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/11/2022
Special inspection requirement — Masonry
Howard Zimmerman
07/11/2022
Special inspection requirement — Final
Howard Zimmerman
07/11/2022
Special inspection requirement — Post-installed Anchors
Howard Zimmerman
07/11/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Howard Zimmerman
07/08/2022
Filed — Alteration
FISP REPAIRS TO INCLUDE MASONRY REPLACEMENT AND CRACK REPAIRS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00523563-P1
07/07/2022
Special inspection requirement — Final
Howard Zimmerman
07/07/2022
Special inspection requirement — Masonry
Howard Zimmerman
07/07/2022
Special inspection requirement — Post-installed Anchors
Howard Zimmerman
07/07/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Howard Zimmerman
02/25/2022
Permit issued — General Construction
M00523563-I1-GC
02/18/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
02/16/2022
Cycle 9 facade report submitted
02/16/2022
Cycle 9 facade report signed — UNSAFE
02/16/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/16/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/15/2022
Violation issued (HPD, closed)
A
01/27/2022
Cycle 9 facade inspection completed
01/24/2022
Inspection — Certified Sprinkler (PL)-SP-Fixtures (PL)-Finish
Certified
View inspection ↗
01/21/2022
Permit issued — Sidewalk Shed
M00663194-I1-SH
01/20/2022
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00663194-I1
01/19/2022
Inspection — Certified Sprinkler (PL)-Sprinkler-Hydro
Certified
View inspection ↗
01/19/2022
Inspection — Certified Sprinkler (PL) - SP - Roughing
Certified
View inspection ↗
01/12/2022
Permit issued — General Construction
M00467603-I1-GC
12/23/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/20/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/16/2021
Filed — Alteration
REPLACE EXISTING DRY CLEANING MACHINE. REMOVE EXISTING PARTITION AND DOOR. NO CHANGE IN USE, OCCUPANCY, OR EGRESS IS INVOLVED UNDER THIS APPLICATION.
M00467603-P1
12/10/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/03/2021
Permit issued — Plumbing
M00607366-I1-PL
11/17/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUNG HO SHIN
10/08/2021
Filed — Alteration
TWO NEW SPRINKLER HEADS.
M00607366-I1
10/07/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
SUNG HO SHIN
10/05/2021
Permit issued — General Construction
M00467603-I1-GC
08/06/2021
Filed — Alteration
REPLACE EXISTING DRY CLEANING MACHINE. REMOVE EXISTING PARTITION AND DOOR. NO CHANGE IN USE, OCCUPANCY, OR EGRESS IS INVOLVED UNDER THIS APPLICATION.
M00467603-I1
06/16/2021
Objection raised — Other
06/16/2021
Objection resolved — Addressed
06/16/2021
Objection raised — Other
06/16/2021
Objection resolved — Addressed
06/01/2021
Filed — Alteration
FISP REPAIRS TO INCLUDE MASONRY REPLACEMENT AND CRACK REPAIRS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M00523563-I1
02/10/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Young Suh
02/10/2021
Special inspection requirement — Sprinkler Systems
Young Suh
02/05/2021
Filed — Alteration
plumbing and sprinkler modifications to accommodate relocation of the existing laundry. additionally filing to resolve open violations
M00431123-P1
02/05/2021
Special inspection requirement — Sprinkler Systems
Young Suh
02/05/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Young Suh
Latest 60 of 124 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignPermit IssuedDESTHERS, JOSEPH02/25/2025
DOB NOWGeneral ConstructionSigned-offEXO INDUSTRIES CORP02/25/2022
DOB NOWSidewalk ShedSigned-offEXO INDUSTRIES CORP01/21/2022
DOB NOWGeneral ConstructionSigned-offECOTECH MACHINERY LLC01/12/2022
DOB NOWPlumbingPermit IssuedWASOFF PLBG & UTILITY CO12/03/2021
DOB NOWGeneral ConstructionSigned-offECOTECH MACHINERY LLC10/05/2021
DOB NOWPlumbingSigned-offABR PLBG & HTG CONTR. INC12/16/2020
DOB NOWPlumbingSigned-offABR PLBG&HTG CONTR INC12/16/2020
BISOTISSUEDCARLETON RESTORATION INC01/12/2021
BISOTISSUEDKEYSTONE CUSTOM RENOVATIO05/31/2019
BISMHISSUEDLANE REFRIGERATION CO.,IN12/28/2017
BISFPISSUEDUNIQUE FIRE SYSTEMS INC10/26/2016
BISMHISSUEDKEYSTONE CUSTOM RENOVATIO10/19/2016
BISPLISSUEDSAI JI PLUMBING, INC09/06/2016
BISOTISSUEDKEYSTONE CUSTOM RENOVATIO08/22/2016
BISFPISSUEDMETFLOW FIRE CONTROL LLC01/04/2016
BISPLISSUEDORION PLUMBING & HTG CORP10/19/2015
BISOTISSUEDCONSTRUCTION EXPERT INC09/30/2015
BISEQISSUEDCONSTRUCTION EXPERT INC09/24/2015
BISPLISSUEDG.BASSOLINO PLUMBING LTD04/14/2014
BISOTISSUEDCASPER & GAMBINI ENTPRS C04/14/2014
BISPLISSUEDABR PLBG&HTG CONTR INC09/09/2010
BISBLISSUEDSTEPHEN BRAUN03/30/2010
BISOTISSUEDLCS RESTORATION CORP04/03/2009
BISEQISSUEDADVANCED INSTALLATIONS IN01/06/2009
BISEQISSUEDADVANCED INSTALLATIONS IN01/06/2009
BISEQISSUEDADVANCED INSTALLTION INC07/14/2008
BISOTISSUEDLOPEZ CONSTRUCTION SERV., CORP.05/01/2008
BISEQISSUEDADVANCED INSTALLATIONS INC01/02/2008
BISEQISSUEDADVANCED INSTALLATIONS INC11/08/2007
BISFPISSUEDNEW YORK BUSINESS FIR E SYSTEM03/23/2006
BISEQISSUEDJNL CONSTRUCTION INC.01/05/2006
BISOTISSUEDJNL CONSTRUCTION INC.01/05/2006
BISPLISSUEDPETER PLUMBING ASSOC. INC.11/09/2005
BISOTISSUEDKORMAN DESIGN & BUILD11/07/2005
BISEQISSUED55C CONSTRUC. CORP08/19/2005
BISPLISSUEDTOWER PLUMBING & HTG CORP05/05/2004
BISMHISSUEDSAMIRO SERVICES INC04/28/2004
BISFPISSUEDALLIED FIRE_CONTROL04/23/2004
BISFSISSUEDAPPROVED OIL CO OF BKLYN02/11/2004
+ 17 more permits on file
1 project · most recent 10/08/2021
Plumbing-Sprinkler
FiledStatusContractorScope
10/08/2021Permit IssuedWASOFF PLBG & UTILITY COPlumbing-Sprinkler
7 projects · most recent 04/03/2024
General Wiring
FiledStatusContractorScope
04/03/2024CompletePK ELECTRIC INCGeneral Wiring
02/01/2023CompletePK ELECTRIC INC177 meters, 1 new_meters
01/21/2022CompleteRICHARD NEU—
01/19/2022CompletePK ELECTRIC INCGeneral Wiring
02/25/2021CompleteBASS ELECTRICAL CORP.General Wiring
01/23/2020CompleteFAS ELECTRIC, INC.General Wiring
12/14/2018CompleteCORE ELECTRICAL CORP—
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
07/25/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/22/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/18/2022Pass-Final General Construction Non-Directive 14PassView ↗
01/24/2022Certified Sprinkler (PL)-SP-Fixtures (PL)-FinishCertifiedView ↗
01/19/2022Certified Sprinkler (PL)-Sprinkler-HydroCertifiedView ↗
01/19/2022Certified Sprinkler (PL) - SP - RoughingCertifiedView ↗
12/23/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/20/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/10/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
02/17/2025FinalYou Gaoprogress
02/17/2025Structural Stability – Alterations of existing buildingsYou Gaospecial
07/11/2022MasonryHoward Zimmermanspecial
07/11/2022FinalHoward Zimmermanprogress
07/11/2022Post-installed AnchorsHoward Zimmermanspecial
07/11/2022Structural Stability – Alterations of existing buildingsHoward Zimmermanspecial
07/07/2022FinalHoward Zimmermanprogress
07/07/2022MasonryHoward Zimmermanspecial
07/07/2022Post-installed AnchorsHoward Zimmermanspecial
07/07/2022Structural Stability – Alterations of existing buildingsHoward Zimmermanspecial
11/17/2021Fire-Resistant Penetrations and JointsSUNG HO SHINspecial
10/07/2021Fire-Resistant Penetrations and JointsSUNG HO SHINspecial
02/10/2021Fire-Resistant Penetrations and JointsYoung Suhspecial
02/10/2021Sprinkler SystemsYoung Suhspecial
02/05/2021Sprinkler SystemsYoung Suhspecial
02/05/2021Fire-Resistant Penetrations and JointsYoung Suhspecial
▾Documents — 241 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch5
09/03/2026M00607366-I1Request digital key ↗
09/03/2026M00663194-I1Request digital key ↗
09/02/2026M00523563-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Sprinkler2
09/04/2026M00431123-I1Request digital key ↗
08/15/2026M00431123-P1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction2
09/03/2026M00467603-I1Request digital key ↗
09/03/2026M00467603-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing2
09/04/2026M00431123-I1Request digital key ↗
08/15/2026M00431123-P1Request digital key ↗
▸Applications & Permits57
▸BISPLAN / WORK APPROVAL APPLICATION31
06/05/2019140404060Open ↗
05/29/2019140404060Open ↗
05/29/2019140537970Open ↗
Showing 3 of 31 on file for this type
▸BISWORK PERMIT APPLICATION25
01/13/2021140982569Open ↗
05/31/2019140537970Open ↗
05/31/2019140537970Open ↗
Showing 3 of 25 on file for this type
▸BISLL114/19 PERMIT RESTRICTION1
12/23/2020140982569Open ↗
▸Seals & Professional Certifications56
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION13
12/02/2019140404060Open ↗
12/26/2018140404060Open ↗
12/28/2017123267776Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/03/2026M00663194-I1Open ↗
09/02/2026M00523563-I1Open ↗
08/24/2026M01182183-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/20/2026M00431123-I1Open ↗
09/20/2026M00431123-I1Open ↗
09/02/2026M00431123-P1Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
12/28/2017123267776Open ↗
10/20/2016122918502Open ↗
08/28/2010120456452Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT5
12/28/2017123267776Open ↗
10/20/2016122918502Open ↗
08/19/2016140537970Open ↗
Showing 3 of 5 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION3
08/19/2016140537970Open ↗
09/18/2015140404060Open ↗
04/14/2014140185216Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
08/19/2016140537970Open ↗
09/18/2015140404060Open ↗
04/14/2014140185216Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
08/28/2010120456452Open ↗
03/31/2010120300423Open ↗
07/11/2008110240999Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/26/2026M01182183-I1Open ↗
08/25/2026M00523563-I1Open ↗
08/22/2026M00523563-P1Open ↗
▸BISPC FULL REPORT2
12/10/2007110021486Open ↗
10/24/2007110000374Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
11/25/2020140982569Open ↗
▸Trade Schedules & Equipment16
▸BISSCHEDULE B - PLUMBING4
08/19/2016140537970Open ↗
09/18/2015140404060Open ↗
04/14/2014140185216Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT3
04/14/2014140185216Open ↗
03/17/2011120300423Open ↗
03/31/2010120300423Open ↗
▸BISSELF-CERT PLUMBING NOTICE3
10/09/2014140185216Open ↗
08/11/2014140185216Open ↗
10/01/2010120456452Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA2
05/15/2017122918502Open ↗
08/01/2016122620299Open ↗
▸BISBOILERS - SUPPORTING DOCUMENTATION1
10/09/2014140185216Open ↗
▸BISFIRE PROTECTION PLAN(FPP): FDNY APPROVAL1
10/28/2016122918502Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
07/05/2018123267776Open ↗
▸BISEQUIPMENT USE PERMITS1
07/05/2018123267776Open ↗
▸Safety & Tenant Protection3
▸DOB NOWTenant Protection Plan2
08/13/2026M00431123-P1Open ↗
08/13/2026M00431123-I1Open ↗
▸BISTPP1: TENANT PROTECTION PLAN1
12/01/2020140982569Open ↗
▸Environmental & Asbestos16
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/14/2026M00523563-I1Open ↗
08/13/2026M00607366-I1Open ↗
08/13/2026M00467603-P1Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
12/01/2020140982569Open ↗
08/19/2016140537970Open ↗
09/18/2015140404060Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER3
07/11/2008110240999Open ↗
12/10/2007110021486Open ↗
10/24/2007110000374Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
08/28/2010120456452Open ↗
03/31/2010120300423Open ↗
▸Energy Compliance17
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY6
12/23/2020140982569Open ↗
12/23/2020140982569Open ↗
12/01/2020140982569Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS5
12/02/2019140404060Open ↗
12/26/2018140404060Open ↗
07/05/2018123267776Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS3
08/19/2016140537970Open ↗
09/18/2015140404060Open ↗
04/14/2014140185216Open ↗
▸BISAS-BUILT ENERGY ANALYSIS3
12/02/2019140404060Open ↗
07/05/2018123267776Open ↗
12/03/2015140185216Open ↗
▸Inspections & Test Reports6
▸BISTECHNICAL REPORT: RESPONSIBILITY6
12/23/2020140982569Open ↗
12/23/2020140982569Open ↗
12/01/2020140982569Open ↗
Showing 3 of 6 on file for this type
▸Approvals, Objections & Sign-offs14
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
12/02/2019140404060Open ↗
07/05/2018123267776Open ↗
05/15/2017122918502Open ↗
Showing 3 of 7 on file for this type
▸BISADMINISTRATIVE OBJECTIONS5
08/28/2010120456452Open ↗
03/31/2010120300423Open ↗
07/11/2008110240999Open ↗
Showing 3 of 5 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
08/11/2014140185216Open ↗
06/28/2010110021486Open ↗
▸Cost, Insurance & Ownership17
▸BISCOST AFFIDAVIT16
12/01/2020140982569Open ↗
12/02/2019140404060Open ↗
07/05/2018123267776Open ↗
Showing 3 of 16 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT1
09/02/2010120456452Open ↗
▸Filing & Intake Forms27
▸BISBOROUGH INTAKE FORM11
12/02/2019140404060Open ↗
05/29/2019140404060Open ↗
05/21/2019140537970Open ↗
Showing 3 of 11 on file for this type
▸BISEFILING COVER SHEET6
12/28/2017123267776Open ↗
10/20/2016122918502Open ↗
12/22/2015122620299Open ↗
Showing 3 of 6 on file for this type
▸BISADDITIONAL INFORMATION6
12/13/2020140982569Open ↗
05/29/2019140537970Open ↗
04/25/2019140537970Open ↗
Showing 3 of 6 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET4
11/25/2020140982569Open ↗
08/19/2016140537970Open ↗
09/18/2015140404060Open ↗
Showing 3 of 4 on file for this type
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
08/11/2014140185216Open ↗