DOB03/02/2022FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB12/02/2021WORK WITHOUT A PERMIT. AT TIME OF INSPECTION OBSERVED PLYWOOD SHEATHING HAS BEEN REMOVED FROM EXPO #1/4 REPLACED WITH NEW. ALSO NOTE: DENS GLASS TYPE COVERING INSTALLED ON EXPOS#4. NO PERMITS., REPAIR AND/OR RE$3K due
ECB12/02/2021FAILURE TO INSTITUTE AND MAINTAIN ADEQUATE SAFETY MEASURES-FALL PROTECTION/SCAFFOLD. (BC 3301.2). AT TIME OF INSPECTION OBSERVED AT EXPOSURE #1/4 SCAFFOLDING HAS BEEN ERECTED WHERE WORK PLATFORMS NOT FULLY PLAN$10K due
ECB12/02/2021FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT EXPO#4 FIRE BALCONY DROP LADDER AND PATHWAY OBSTRUCTED BY CONSTRUCTION MATERIAL BEING STORED UNDER DROP LADDER AND GATE S$6K due
DOB09/21/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/24/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
HPD02/17/2014SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR AT CELLAR
HPD02/17/2014SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 3RDF, 3rd STORY
HPD02/17/2014SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. LOCATED AT APT 3RDF, 3rd STORY
HPD06/13/1991SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WINDOW GLASS CELLAR SOUTH & EAST.
HPD06/13/1991D26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION PUBLIC HALLS ALL STYS.
HPD06/13/1991D26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CELLAR THRU OUT.
HPD06/13/1991D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING 3 STY PUBLIC HALL R21.
HPD06/13/1991D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING REAR YARD & SOUTH COURT R35.
HPD06/13/1991SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ASPHALT SHINGLES 2 STY REAR BLDG.
HPD06/13/1991D26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 50 WATTS FRONT.
HPD06/13/1991D26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ARTICLES 1 STY PUBLIC HALL R16.
HPD06/13/1991D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING BALUSTER 1 THRU 2 STY PUBLIC HALL.
HPD05/29/1986D26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CELLAR THRU OUT R31.
HPD05/29/1986D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS SOUTHEAST AT CELLAR.
HPD05/29/1986D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING NORTHEAST CELLAR.
HPD06/17/1985SECTION 65 M/D LAW PROVIDE UNDER COMPLETED PERMIT, A PROPER ENCLOSURE FOR THE CENTRAL HEATING PLANT, FRONT CELLAR.
HPD06/17/1985D26-34.01 ADM CODE DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES AND PROPERLY SEAL PIPE CONNECTIONS CELLAR THRU OUT.
HPD06/17/1985D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING FIREPROOF SELF CLOSING DOOR BOTTOM OF CELLAR ON STAIRS CELLAR CENTER.
ECB07/30/2016FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN NOV #35154645R ISSUED ON 11/23/15 & TO FILE A C OF C PURSUANT TO 28-201.1,28-204.4 & 1RCNY102-01. FOR WORK W/O A PERMIT. REMEDY: COMPLY W/COMM'S ORDER &/OR FILENothing owed — awaiting certificate of correction
ECB06/30/2016FAILURE TO MAINTAIN PREMISES IN CODE COMPLAINT MANNER. OBSERVED CONBUSTIBLE DEBRIS IN REAR YARD PILED OVER 10'HIGH. OBSERVED LIVE STOCK SCAMPERING FROM PILE OF DEBRIS,BIRDS,CATS & RACCOON. REMEDY: MAKE SAFE SAFNothing owed — awaiting certificate of correction
ECB06/30/2016ILLEGAL USE IN A RESIDENTIAL DISTRICT.RESIDENTIAL DISTRICT IS R5.OBSERVED MOTOR VEHICLE STORED IN SIDE YARD WITH NO VISIBLE LICENSE PLATE,CREATING A DEAD STORAGE CONDITION NOT PERMISSIBLE IN A RESIDENTIAL DISTRNothing owed — awaiting certificate of correction
ECB06/14/2016FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN NOV #35154645R ISSUED ON 11/23/15 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1,28-204.4 & 1RCNY 102-01.WORK W/OUT PERMIT.REAR EXTENSION.REM:COMPLY W/COMMNothing owed — awaiting certificate of correction
ECB11/23/2015WORK W/ PERMIT.WORK NOTED: EXTENSION IS BEING ADDED TO THE BUILDING STRUCTURE A 3STORIES IS BEING FRAME GUT APPRX 20% OF THE WORK COMPLET ED. STOP ALL WORK.RMDY: OBTAIN PERMIT MAKE SITE SAFE CALL THE OFFICENothing owed — awaiting certificate of correction