← Back
Three families
72-08 74 STREET
QUEENS · BIN 4625194
💬 Discuss this project
2024Year Built
4Stories
C0Building Class
R5Zoning
3,828 sfGross Floor Area
3Units
5 Open Violations 1 unresolved · 4 paperwork only ▸
Three families · Owner of record: MURRY HILL REALTY LLC · 3,700 sf lot · 1.03 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalFire Protection
Roof2p · 2 filings · 12 docs
Floor 41p · 1 filing · 4 docs
Floor 32p · 1 filing · 4 docs
Floor 23p · 3 filings · 18 docs
Floor 12p · 2 filings · 12 docs
Cellar2p · 2 filings · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SAFETY PRO CONSTRUCTION103/22/2026
L & L CONSTRUCTION DEVELO703/22/2026
PROFESSIONAL MORTGAGE SOLUTIONS IN603/21/2026
MURRY HILL REALTY403/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/19/2024$775K—72-08 45 AVENUE CORP. → MURRY HILL REALTY LLC$202/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ZHENG & ASSOCIATES LLC601/16/2026
A&B WORLD CONSULTING108/02/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
YBL NY203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&L CONSTRUCTION DEVELOPGeneral Contractor303/21/2026
SAFETY PRO CONSTRUCTIONGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ZHENG & ASSOCIATES LLC7330207/31/2024
Building Lifecycle
All (67)Filed (7)Permit Issued (2)Violation (11)Objection (17)Special Inspection (30)
02/09/2026
Objection raised — Zoning
02/09/2026
Objection raised — Scope
02/09/2026
Objection raised — Zoning
02/09/2026
Objection raised — Zoning
02/09/2026
Objection raised — Scope
02/09/2026
Objection raised — Plumbing
02/09/2026
Objection raised — Scope
02/09/2026
Objection raised — Energy
02/09/2026
Objection raised — Scope
01/16/2026
Filed — New Building
NEW 3 STORY BRICK BUILDING. PROPOSED 3 FAMILY DWELLING UNITS.
Q01280725-I1
12/16/2025
Permit issued — Construction Fence
Q01022563-I1-FN
11/21/2025
Violation issued (ECB, closed)
Construction
09/02/2025
Special inspection requirement — HVAC-R and service water heating system controls
09/02/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
09/02/2025
Special inspection requirement — Final
09/02/2025
Special inspection requirement — Mechanical Systems
09/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
09/02/2025
Special inspection requirement — Heating Systems
09/02/2025
Special inspection requirement — Energy Code Compliance Inspections
09/02/2025
Special inspection requirement — Fire-Resistance Rated Construction
09/02/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
09/02/2025
Special inspection requirement — Permanent certificate
09/02/2025
Special inspection requirement — Air barrier — testing
09/02/2025
Special inspection requirement — Fenestration areas
09/02/2025
Special inspection requirement — Protection of exposed foundation insulation
09/02/2025
Special inspection requirement — Interior lighting power
09/02/2025
Special inspection requirement — Air barrier - visual inspection
09/02/2025
Special inspection requirement — Insulation placement and R values
09/02/2025
Special inspection requirement — Ventilation and air distribution system
09/02/2025
Special inspection requirement — Fenestration air leakage
09/02/2025
Special inspection requirement — Maintenance information
09/02/2025
Special inspection requirement — Metering
09/02/2025
Special inspection requirement — HVAC-R and service water heating equipment
11/21/2024
Violation issued (ECB, open)
Construction
10/30/2024
Violation issued (ECB, open)
Construction
10/29/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/28/2024
Violation issued (ECB, closed)
Construction
10/28/2024
Violation issued (ECB, open)
Construction
10/28/2024
Violation issued (ECB, open)
Site Safety
10/28/2024
Violation issued (ECB, closed)
Unknown
10/28/2024
Violation issued (ECB, closed)
Unknown
08/05/2024
Permit issued — Structural
Q01074315-I1-ST
07/31/2024
Filed — Alteration
FILE STRUCTURE PLAN FOR THE NB JOB.
Q01074315-I1
06/29/2024
Special inspection requirement — Structural Steel - Details
Jinfar Liu
06/29/2024
Special inspection requirement — Final
Jinfar Liu
06/29/2024
Special inspection requirement — Concrete - Cast-In-Place
Jinfar Liu
06/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jinfar Liu
06/29/2024
Special inspection requirement — Masonry
Jinfar Liu
06/29/2024
Special inspection requirement — Structural Steel - High Strength Bolting
Jinfar Liu
06/10/2024
Filed — Alteration
FILE FOUNDATION WORK & EARTH WORK FOR PROPOSED NEW BUILDING.
Q01060978-I1
03/20/2024
Filed — Alteration
INSTALL NEW TEMPORARY CONSTRUCTION FENCE.
Q01022563-I1
08/28/2022
Objection raised — Inspections
08/28/2022
Objection resolved — Addressed
08/28/2022
Objection raised — Zoning
08/28/2022
Objection resolved — Addressed
08/28/2022
Objection raised — Scope
08/28/2022
Objection resolved — Addressed
08/28/2022
Objection raised — Zoning
08/28/2022
Objection resolved — Addressed
08/23/2022
Filed — Alteration
CURB CUT IN-CONJUNCTION WITH NB #440666691.
Q00475248-I1
Latest 60 of 67 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedSAFETY PRO CONSTRUCTION12/16/2025
DOB NOWStructuralPermit IssuedL&L CONSTRUCTION DEVELOP08/05/2024
BIS—ISSUEDL&L CONSTRUCTION DEVELOP09/16/2024
1 project · most recent 01/16/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
01/16/2026——Heating and Air Conditioning Systems
Heat / Cool
2 projects · most recent 07/31/2024
Steel Masonry
FiledStatusContractorScope
07/31/2024Permit IssuedL&L CONSTRUCTION DEVELOPSteel, Masonry
06/10/2024Permit IssuedJIN SUN CONSTRUCTION INC1 scope_items
1 project · most recent 03/20/2024
Fence
FiledStatusContractorScope
03/20/2024Permit IssuedSAFETY PRO CONSTRUCTIONFence
1 project · most recent 06/10/2024
Earthwork
FiledStatusContractorScope
06/10/2024Permit IssuedJIN SUN CONSTRUCTION INCEarthwork
▾Special Inspection Requirements (DOB NOW) — 39
DateRequirementInspectorRole
09/02/2025HVAC-R and service water heating system controls—energy_progress
09/02/2025HVAC-R and service water piping design and insulation—energy_progress
09/02/2025Final—progress
09/02/2025Mechanical Systems—special
09/02/2025Fire-Resistant Penetrations and Joints—special
09/02/2025Heating Systems—special
09/02/2025Energy Code Compliance Inspections—progress
09/02/2025Fire-Resistance Rated Construction—progress
09/02/2025Fenestration and door U-factor and product ratings—energy_progress
09/02/2025Permanent certificate—energy_progress
09/02/2025Air barrier — testing —energy_progress
09/02/2025Fenestration areas—energy_progress
09/02/2025Protection of exposed foundation insulation—energy_progress
09/02/2025Interior lighting power—energy_progress
09/02/2025Air barrier - visual inspection—energy_progress
09/02/2025Insulation placement and R values—energy_progress
09/02/2025Ventilation and air distribution system—energy_progress
09/02/2025Fenestration air leakage—energy_progress
09/02/2025Maintenance information—energy_progress
09/02/2025Metering—energy_progress
09/02/2025HVAC-R and service water heating equipment—energy_progress
06/29/2024Structural Steel - DetailsJinfar Liuspecial
06/29/2024FinalJinfar Liuprogress
06/29/2024Concrete - Cast-In-PlaceJinfar Liuspecial
06/29/2024Fire-Resistant Penetrations and JointsJinfar Liuspecial
Latest 25 of 39.
▾Documents — 95 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch4
08/23/2026Q01022563-I1Request digital key ↗
08/22/2026Q01060978-I1Request digital key ↗
08/21/2026Q01074315-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/27/2026Q00475252-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Curb Cut1
08/15/2026Q00475248-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
08/27/2026Q00475249-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/27/2026Q00475249-I1Request digital key ↗
▸Applications & Permits21
▸BISPLAN / WORK APPROVAL APPLICATION15
02/25/2026440666691Open ↗
09/26/2024440666691Open ↗
08/01/2024440666691Open ↗
Showing 3 of 15 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION3
07/03/2024440666691Open ↗
05/01/2024440666691Open ↗
04/19/2024440666691Open ↗
▸BISWORK PERMIT APPLICATION2
06/20/2025440666691Open ↗
06/03/2025440666691Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
10/26/2023440666762Open ↗
▸Zoning, Tax Lot & Property Records6
▸BISZONING DIAGRAM2
08/01/2024440666691Open ↗
03/06/2023440666691Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
03/04/2021440666691Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
03/04/2021440666691Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01280725-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01280725-I1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/22/2026Q01060978-I1Open ↗
08/17/2026Q01280725-I1Open ↗
08/13/2026Q00475248-I1Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
03/04/2021440666691Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/02/2026Q01074315-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/02/2026Q01074315-I1Open ↗
▸Trade Schedules & Equipment2
▸BISDEP STORMWATER SEWER CERTIFICATION (HCP/SCP)1
07/12/2022440666691Open ↗
▸BISDEP SANITARY SEWER CERTIFICATION (HCP/SCP)1
07/12/2022440666691Open ↗
▸Safety & Tenant Protection5
▸BISBPP: STREET TREES SITE PLAN1
06/08/2021440666762Open ↗
▸BISSTREET TREE CHECKLIST1
03/04/2021440666691Open ↗
▸BISSTREET TREES SITE PLAN1
10/26/2023440666762Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
06/08/2021440666762Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01280725-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
04/24/2024440666691Open ↗
03/04/2021440666691Open ↗
▸BISTR8: ENERGY CODE PROGRESS INSPS TECHNICAL REPORT1
07/12/2022440666691Open ↗
▸Inspections & Test Reports12
▸BISTECHNICAL REPORT: RESPONSIBILITY4
04/24/2024440666691Open ↗
03/04/2021440666691Open ↗
03/04/2021440666691Open ↗
Showing 3 of 4 on file for this type
▸BISSOIL PERC. TEST-PVT ON-SITE STORM WATER DRAINAGE DISPOSAL SYS & DET. FACL.1
08/02/2024440666691Open ↗
▸BISSOIL REPORT1
03/04/2021440666691Open ↗
▸BISTR3: CONCRETE DESIGN MIX TECHNICAL REPORT1
08/02/2024440666691Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
03/04/2021440666691Open ↗
▸BISTR2: CONCRETE FIELD TESTING TECHNICAL REPORT1
08/02/2024440666691Open ↗
▸DOB NOWHydrant Flow Test Letter1
08/27/2026Q00475249-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01060978-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01060978-I1Open ↗
▸Approvals, Objections & Sign-offs5
▸BISSCHEDULE A - OCCUPANCY / USE5
05/17/2024440666691Open ↗
05/06/2024440666691Open ↗
09/16/2022440666691Open ↗
Showing 3 of 5 on file for this type
▸Cost, Insurance & Ownership3
▸BISPROJECT-SPECIFIC GL INSURANCE3
06/20/2025440666691Open ↗
06/03/2025440666691Open ↗
08/02/2024440666691Open ↗
▸Filing & Intake Forms10
▸BISADDITIONAL INFORMATION5
05/20/2024440666691Open ↗
05/01/2024440666691Open ↗
04/19/2024440666691Open ↗
Showing 3 of 5 on file for this type
▸BISBOROUGH INTAKE FORM2
06/20/2025440666691Open ↗
06/03/2025440666691Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
06/07/2021440666762Open ↗
03/04/2021440666691Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
06/07/2021440666762Open ↗
▸Other Documents10
▸BISBPP - SUPPORTING DOCUMENTATION2
10/26/2023440666762Open ↗
10/26/2023440666762Open ↗
▸BISSupporting Document: Fee Deferment1
08/26/2021440666691Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
03/04/2021440666691Open ↗
▸BISPLOT DIAGRAM1
04/16/2021440666691Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01280725-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q01060978-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/14/2026Q01280725-I1Open ↗
▸DOB NOWHydraulic Calculations1
08/13/2026Q00475249-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01280725-I1Open ↗