← Back
Three families
72-10 DITMARS BOULEVARD
QUEENS · BIN 4021800
💬 Discuss this project
1960Year Built
3Stories
C0Building Class
R4Zoning
2,902 sfGross Floor Area
3Units
0 Open Violations
Three families · 2,700 sf lot · 1.07 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/21/2024$1.4M—Private party → Private party$500/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ENGINEERING CONSULTING SERVICES209/30/2025
M. KARANTINIDIS PE111/08/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MK EXP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALPHA TECH RENOVATIONSGeneral Contractor204/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ENGINEERING CONSULTING SE2050209/30/2025
INTERNATIONAL GEOTEHCNICA1795111/08/2024
Building Lifecycle
All (38)Filed (3)Permit Issued (2)Signed Off (1)Violation (2)Objection (16)Special Inspection (14)
05/05/2026
Violation issued (ECB, closed)
Unknown
12/29/2025
Signed off — Alteration
PROPOSE TO INSTALL NEW METAL DECK AT THE REAR AND FRONT OF EXISTING DWELLING ON THE SECOND FLOOR LEVEL.
Q01179617-I1
10/28/2025
Special inspection requirement — Subgrade Inspections
PAUL MARINO
10/28/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
PAUL MARINO
10/28/2025
Special inspection requirement — Final
Patrizia Cimino
10/17/2025
Violation issued (ECB, closed)
Construction
09/30/2025
Filed — Alteration
PROPOSE TO INSTALL NEW METAL DECK AT THE REAR AND FRONT OF EXISTING DWELLING ON THE SECOND FLOOR LEVEL.
Q01179617-P1
09/29/2025
Special inspection requirement — Final
Patrizia Cimino
09/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
PAUL MARINO
09/29/2025
Special inspection requirement — Subgrade Inspections
PAUL MARINO
09/09/2025
Permit issued — General Construction
Q01179617-I1-GC
07/08/2025
Permit issued — General Construction
Q01179617-I1-GC
04/02/2025
Objection raised — Cost
04/02/2025
Objection resolved — Addressed
04/02/2025
Objection resolved — Addressed
03/25/2025
Objection raised — Zoning
03/13/2025
Filed — Alteration
PROPOSE TO INSTALL NEW METAL DECK AT THE REAR AND FRONT OF EXISTING DWELLING ON THE SECOND FLOOR LEVEL.
Q01179617-I1
11/19/2024
Objection raised — Structural
11/19/2024
Objection raised — Admin
11/19/2024
Objection raised — Scope
11/19/2024
Objection raised — Admin
11/19/2024
Objection raised — Other
11/19/2024
Objection raised — Other
11/19/2024
Objection raised — Other
11/19/2024
Objection raised — Structural
11/19/2024
Objection raised — Energy
11/19/2024
Objection raised — Other
11/19/2024
Objection raised — Scope
11/19/2024
Objection raised — Other
11/08/2024
Filed — Alteration
Q01126723-I1
10/14/2024
Special inspection requirement — Structural Cold-Formed Steel
MICHAEL KARANTINIDIS, P.E.
10/14/2024
Special inspection requirement — Structural Steel - Details
MICHAEL KARANTINIDIS, P.E.
10/14/2024
Special inspection requirement — Energy Code Compliance Inspections
MICHAEL KARANTINIDIS, P.E.
10/14/2024
Special inspection requirement — Final
MICHAEL KARANTINIDIS, P.E.
10/14/2024
Special inspection requirement — Footing and Foundation
MICHAEL KARANTINIDIS, P.E.
10/14/2024
Special inspection requirement — Structural Steel - High Strength Bolting
MICHAEL KARANTINIDIS, P.E.
10/14/2024
Special inspection requirement — Structural Steel - Welding
MICHAEL KARANTINIDIS, P.E.
10/14/2024
Special inspection requirement — Subgrade Inspections
MICHAEL KARANTINIDIS, P.E.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offALPHA TECH RENOVATIONS09/09/2025
DOB NOWGeneral ConstructionSigned-offALPHA TECH RENOVATIONS07/08/2025
1 project · most recent 05/11/2026
General Wiring
FiledStatusContractorScope
05/11/2026Permit IssuedJOSEPH WEINSTEIN ELECTRICGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
10/28/2025Subgrade InspectionsPAUL MARINOspecial
10/28/2025Structural Stability – Alterations of existing buildingsPAUL MARINOspecial
10/28/2025FinalPatrizia Ciminoprogress
09/29/2025FinalPatrizia Ciminoprogress
09/29/2025Structural Stability – Alterations of existing buildingsPAUL MARINOspecial
09/29/2025Subgrade InspectionsPAUL MARINOspecial
10/14/2024Structural Cold-Formed SteelMICHAEL KARANTINIDIS, P.E.special
10/14/2024Structural Steel - DetailsMICHAEL KARANTINIDIS, P.E.special
10/14/2024Energy Code Compliance InspectionsMICHAEL KARANTINIDIS, P.E.progress
10/14/2024FinalMICHAEL KARANTINIDIS, P.E.progress
10/14/2024Footing and FoundationMICHAEL KARANTINIDIS, P.E.progress
10/14/2024Structural Steel - High Strength BoltingMICHAEL KARANTINIDIS, P.E.special
10/14/2024Structural Steel - WeldingMICHAEL KARANTINIDIS, P.E.special
10/14/2024Subgrade InspectionsMICHAEL KARANTINIDIS, P.E.special
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026Q01126723-I1Request digital key ↗
08/20/2026Q01179617-P1Request digital key ↗
08/14/2026Q01179617-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026Q01126723-I1Open ↗
08/20/2026Q01179617-I1Open ↗
08/20/2026Q01179617-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026Q01179617-P1Open ↗
08/23/2026Q01179617-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026Q01179617-P1Open ↗
08/23/2026Q01179617-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026Q01126723-I1Open ↗
08/20/2026Q01179617-P1Open ↗
08/14/2026Q01179617-I1Open ↗