← Back
Five to six families
72 2 PLACE
BROOKLYN · BIN 3005275
💬 Discuss this project
1930Year Built
3.5Stories
C2Building Class
R6BZoning
4,100 sfGross Floor Area
5Units
Rent Stabilized0 Open Violations
Five to six families · Owner of record: 72 SECOND PLACE CORP., A NEW YORK CORPOR ATION · 2,500 sf lot · 1.64 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Cellar1p · 1 filing · 19 docs
Basement2p · 1 filing · 19 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
72 SECOND PLACE CORP904/09/2026
72 SECOND PLACE CORP., A NEW YORK CORPOR ATION103/22/2026
OWNER OF 72 2 PLACE103/22/2026
OWNER OF 72 2 PL.103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOHN H HATHEWAY JR., ARCHITECT212/19/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
OASIS PLOMO CORPGeneral Contractor303/21/2026
SIGNORE & SONS PLBG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JOHN H HATHEWAY JR., ARCH4175212/19/2025
Building Lifecycle
All (45)Filed (2)Permit Issued (2)Signed Off (2)Violation (12)Inspection (6)Objection (8)Special Inspection (13)
06/26/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/25/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/15/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/30/2026
Violation issued (HPD, closed)
A
04/21/2026
Signed off — Alteration
Replace existing bathroom tub with shower as indicated on plans. Install new dishwasher and clothes washer.
B01302773-I1
04/21/2026
Signed off — Alteration
Replace existing bathroom tub with shower as indicated on plans. Install new dishwasher and clothes washer.
B01302773-S1
04/08/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/27/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/16/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/27/2026
Permit issued — General Construction
B01302773-I1-GC
01/22/2026
Permit issued — Plumbing
B01302773-S1-PL
01/08/2026
Objection resolved — Addressed
01/08/2026
Objection resolved — Addressed
12/24/2025
Objection raised — Other
12/19/2025
Filed — Alteration
Replace existing bathroom tub with shower as indicated on plans. Install new dishwasher and clothes washer.
B01302773-S1
12/19/2025
Objection resolved — Addressed
12/19/2025
Objection resolved — Addressed
12/19/2025
Special inspection requirement — Tenant Protection Plan Compliance
John Hatheway
12/15/2025
Objection raised — Scope
12/15/2025
Objection raised — Cost
12/15/2025
Objection raised — Scope
12/11/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
John Hatheway
12/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Hatheway
12/11/2025
Special inspection requirement — Energy Code Compliance Inspections
John Hatheway
12/08/2025
Filed — Alteration
Replace existing bathroom tub with shower as indicated on plans. Install new dishwasher and clothes washer.
B01302773-I1
11/20/2025
Violation issued (HPD, closed)
I
11/19/2025
Special inspection requirement — Air barrier - visual inspection
John Hatheway
11/19/2025
Special inspection requirement — Lighting in dwelling units
John Hatheway
11/19/2025
Special inspection requirement — Interior lighting power
John Hatheway
10/14/2025
Special inspection requirement — Fenestration air leakage
John Hatheway
10/14/2025
Special inspection requirement — Fire-Resistance Rated Construction
John Hatheway
10/14/2025
Special inspection requirement — Final
John Hatheway
10/14/2025
Special inspection requirement — Energy Code Compliance Inspections
John Hatheway
10/14/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
John Hatheway
10/14/2025
Special inspection requirement — Fenestration areas
John Hatheway
06/05/2025
Violation issued (HPD, closed)
A
11/29/2024
Violation issued (HPD, closed)
I
11/22/2023
Violation issued (HPD, closed)
I
02/18/2022
Violation issued (HPD, closed)
A
02/18/2022
Violation issued (HPD, closed)
I
04/05/2021
Violation issued (HPD, closed)
A
10/28/2019
Violation issued (HPD, closed)
I
02/09/2001
Violation issued (ECB, closed)
Quality of Life
02/09/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/29/1994
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offOASIS PLOMO CORP01/27/2026
DOB NOWPlumbingSigned-offSIGNORE & SONS PLBG CORP01/22/2026
1 project · most recent 07/27/2026
General Wiring
FiledStatusContractorScope
07/27/2026CompleteJOSEPH WEINSTEIN ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
06/26/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/25/2026Pass-Final CND-Occupancy InspectionPassView ↗
06/15/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/08/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/27/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/16/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
12/19/2025Tenant Protection Plan ComplianceJohn Hathewayspecial
12/11/2025HVAC-R and service water piping design and insulationJohn Hathewayenergy_progress
12/11/2025Fire-Resistant Penetrations and JointsJohn Hathewayspecial
12/11/2025Energy Code Compliance InspectionsJohn Hathewayprogress
11/19/2025Air barrier - visual inspectionJohn Hathewayenergy_progress
11/19/2025Lighting in dwelling unitsJohn Hathewayenergy_progress
11/19/2025Interior lighting powerJohn Hathewayenergy_progress
10/14/2025Fenestration air leakageJohn Hathewayenergy_progress
10/14/2025Fire-Resistance Rated ConstructionJohn Hathewayprogress
10/14/2025FinalJohn Hathewayprogress
10/14/2025Energy Code Compliance InspectionsJohn Hathewayprogress
10/14/2025Fenestration and door U-factor and product ratingsJohn Hathewayenergy_progress
10/14/2025Fenestration areasJohn Hathewayenergy_progress
▾Documents — 40 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/19/2026B01302773-S1Request digital key ↗
08/15/2026B01302773-I1Request digital key ↗
▸Applications & Permits4
▸BISWORK PERMIT APPLICATION2
09/09/2010320192509Open ↗
08/05/2010320192509Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
07/27/2011320192509Open ↗
07/22/2010320192509Open ↗
▸Seals & Professional Certifications18
▸DOB NOWProgress Inspector Seal & Signature11
08/28/2026B01302773-I1Open ↗
08/28/2026B01302773-I1Open ↗
08/28/2026B01302773-I1Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
05/10/2011320192509Open ↗
05/06/2011320192509Open ↗
07/22/2010320192509Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/19/2026B01302773-I1Open ↗
08/19/2026B01302773-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026B01302773-I1Open ↗
08/22/2026B01302773-S1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING2
07/27/2011320192509Open ↗
07/22/2010320192509Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
09/26/2011320192509Open ↗
▸Environmental & Asbestos4
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
07/22/2010320192509Open ↗
07/22/2010320192509Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/19/2026B01302773-S1Open ↗
08/15/2026B01302773-I1Open ↗
▸Approvals, Objections & Sign-offs5
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
06/13/2012320192509Open ↗
05/10/2011320192509Open ↗
05/06/2011320192509Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS1
07/22/2010320192509Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
03/14/2011320192509Open ↗
07/22/2010320192509Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
07/22/2010320192509Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
07/22/2010320192509Open ↗