← Back
BuildNYC
One family attached or semi-detached
72-85 CALAMUS AVENUE
QUEENS · Woodside · BIN 4056761
💬 Discuss this project
1945Year Built
1Stories
A5Building Class
R4BZoning
847 sfGross Floor Area
1Units
One family attached or semi-detached · 1,928 sf lot · 0.44 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
Floor 1Family Dwelling 1 StoryUnder Construction14p · 1 filing · 20 docs
CellarFamily Dwelling 1 StoryUnder Construction15p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/13/2022$800K—Private party → Private party$945/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Bayside Associates505/19/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
H J Building Consulting803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
American Standard P&H CororpPlumbing207/08/2026
Kale ConstructionGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD Testing & Inspection S7010505/19/2026
Building Lifecycle
07/02/2026
Objection resolved — Resolved
06/06/2026
Objection raised — Cost
05/22/2026
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
Q01175112-I1-GC
05/19/2026
Filed — Alteration CO
PLUMBING WORK OF EXISTING 1 FAMILY DWELLING 1 STORY BUILDING AS PER PLANS FILED HEREWITH. IN CONJUNCTION WITH ALT CO JOB#Q01175112-I1.
Q01175112-P4
05/13/2026
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
53 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedAmerican Standard P&H Cororp05/08/2026
DOB NOWGeneral ConstructionPermit IssuedKale Construction05/22/2025
DOB NOWPlumbingPermit IssuedAmerican Standard P&H Cororp04/23/2025
1 project · most recent 05/19/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
05/19/2026Permit IssuedAmerican Standard P&HGas, Storm, Water/Sanitary
1 project · most recent 05/29/2025
General Wiring
FiledStatusContractorScope
05/29/2025CompleteIntelogic ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
09/12/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/22/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
08/22/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
08/22/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/22/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
05/13/2026HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
05/13/2026HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
05/13/2026Maintenance informationXIUCHENG LIenergy_progress
05/13/2026Permanent certificateXIUCHENG LIenergy_progress
05/13/2026HVAC-R and service water piping design and insulationXIUCHENG LIenergy_progress
05/13/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
05/13/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
07/22/2025Insulation placement and R valuesXIUCHENG LIenergy_progress
07/22/2025Air barrier - visual inspectionXIUCHENG LIenergy_progress
07/22/2025Maintenance informationXIUCHENG LIenergy_progress
07/22/2025Permanent certificateXIUCHENG LIenergy_progress
07/22/2025Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
07/22/2025Fire-Resistance Rated ConstructionXIUCHENG LIprogress
07/22/2025Energy Code Compliance InspectionsXIUCHENG LIprogress
07/22/2025Fenestration air leakageXIUCHENG LIenergy_progress
07/22/2025Fenestration and door U-factor and product ratingsXIUCHENG LIenergy_progress
07/22/2025Interior lighting powerXIUCHENG LIenergy_progress
07/22/2025Fenestration areasXIUCHENG LIenergy_progress
06/20/2025Maintenance informationXIUCHENG LIenergy_progress
06/20/2025Permanent certificateXIUCHENG LIenergy_progress
06/20/2025HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
06/20/2025HVAC-R and service water piping design and insulationXIUCHENG LIenergy_progress
06/20/2025HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
06/20/2025Energy Code Compliance InspectionsXIUCHENG LIprogress
06/20/2025Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
66 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account