← Back
BuildNYC
Condo, residential unit in elevator building
72 EAST 3RD STREET
MANHATTAN · East Village · BIN 1006142
💬 Discuss this project
1900Year Built
5Stories
R4Building Class
R8BZoning
14,367 sfGross Floor Area
20Units
Rent Stabilized1 Active Violation 0 unresolved · 1 paperwork only ▸
Condo, residential unit in elevator building · Owner of record: 72-74 East 3rd Street Condominium · 7,544 sf lot · 1.9 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof3p · 4 filings · 20 docs
Floor 5Unit 5B, Unit 5D, Unit 6A +13p · 7 filings · 20 docs
Floor 4
Floor 3
Floor 2
Floor 1
Site & exterior72-74 East 3rd Street Condominium2p · 2 filings · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
72-74 East 3rd Street Condo2103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Theodore E Klingensmith205/14/2026
BGM Engineering110/28/2025
Wong Architect305/17/2022
Silman104/23/2021
Belmont Freeman Architects104/19/2021
Polise Consulting Engineers104/09/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Rand Engineering & Arch203/21/2026
Socotec603/21/2026
Rip CC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&T ConsultantsGeneral Contractor507/02/2026
T.S.M. Mechanicalspecialty_contractor203/21/2026
Gsa ElectricElectrical103/21/2026
Madison ElectricElectrical103/21/2026
Best DemoGeneral Contractor107/08/2026
AL Plumbing & ContPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Aurora Building Consultan9710205/14/2026
MT Group798110/28/2025
Wong Architect1272305/17/2022
Madsen Engineering5423104/23/2021
MEP Inspections1102204/19/2021
Building Lifecycle
All (81)Filed (9)Permit Issued (6)Signed Off (4)Violation (23)Inspection (4)Objection (5)Special Inspection (30)
07/01/2026
Signed off — Alteration
Removal of off-street walls, fence, gates and associated construction at side yard installed prior to permit issuance to address ECB #34546399R; Installation of new 4 foot walls & self closing gates. Application to supersede DOBNOW filing No. M01167606.
M01390823-I1
06/18/2026
Permit issued — General Construction
M01390823-I1-GC
05/14/2026
Filed — Alteration
Removal of off-street walls, fence, gates and associated construction at side yard installed prior to permit issuance to address ECB #34546399R; Installation of new 4 foot walls & self closing gates. Application to supersede DOBNOW filing No. M01167606.
M01390823-I1
02/02/2026
Objection resolved — Addressed
01/14/2026
Permit issued — General Construction
M01167606-I1-GC
01/05/2026
Objection resolved — Addressed
11/28/2025
Objection raised — Scope
11/26/2025
Objection raised — Admin
11/26/2025
Objection raised — Scope
10/28/2025
Filed — Alteration
STRUCTURAL DESIGN FOR INTERIOR ALTERATIONS FOR UNIT 5D AS. THIS APPLICATION WAS FILED TO REPLACE THE STRUCTURAL WORK-TYPE ASSOCIATED WITH THE PREVIOUSLY APPROVED STRUCTURAL SCOPE UNDER ALT1 APPLICATION No. 103714544. NO CHANGE TO USE EGRESS OR OCCUPANCY.
M01280728-I1
02/10/2025
Filed — Alteration
M01167606-I1
01/15/2025
Special inspection requirement — Tenant Protection Plan Compliance
NOEL WONG
01/15/2025
Special inspection requirement — Final
NOEL WONG
10/09/2024
Signed off — Alteration
Combine exist. apts. 6A and 6B. Non bearing partition removal. New partitions and finishes. No change in use, egress or occupancy
M00736050-I1
07/16/2024
Signed off — Alteration
Combine apts6A and 6B on 5th fl. cap and remove kit fixtures on 6A. New kitchen and bathrooms. No change in use, egress or occupancy
M00738189-I1
07/15/2024
Signed off — Alteration
M00738202-I1
05/23/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/23/2022
Permit issued — General Construction
M00736050-I1-GC
11/23/2022
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
10/21/2022
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
10/18/2022
Permit issued — Mechanical Systems
M00738202-I1-MS
10/06/2022
Inspection — Fail-Final PL - Up to 9 Requested Floors
Fail
View inspection ↗
06/08/2022
Permit issued — Plumbing
M00738189-I1-PL
06/07/2022
Permit issued — General Construction
M00736050-I1-GC
05/17/2022
Filed — Alteration
Combine exist. apts. 6A and 6B. Non bearing partition removal. New partitions and finishes. No change in use, egress or occupancy
M00736050-I1
05/17/2022
Filed — Alteration
Combine apts6A and 6B on 5th fl. cap and remove kit fixtures on 6A. New kitchen and bathrooms. No change in use, egress or occupancy
M00738189-I1
05/17/2022
Filed — Alteration
M00738202-I1
05/13/2022
Special inspection requirement — HVAC-R and service water heating equipment
KING WONG
05/13/2022
Special inspection requirement — Mechanical Systems
KING WONG
05/13/2022
Special inspection requirement — Final
KING WONG
05/13/2022
Special inspection requirement — HVAC-R and service water heating system controls
KING WONG
05/13/2022
Special inspection requirement — Ventilation and air distribution system
KING WONG
05/13/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
KING WONG
05/13/2022
Special inspection requirement — Maintenance information
KING WONG
05/13/2022
Special inspection requirement — Duct leakage testing, insulation and design
KING WONG
05/11/2022
Special inspection requirement — Fire-Resistance Rated Construction
KING WONG
05/11/2022
Special inspection requirement — Lighting in dwelling units
KING WONG
05/11/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
KING WONG
05/11/2022
Special inspection requirement — Final
KING WONG
05/11/2022
Special inspection requirement — Energy Code Compliance Inspections
KING WONG
04/23/2021
Filed — Alteration
FILING HERWITH FOR THE STRUCTURAL FRAMING OF APARTMENT 5B
M00488431-I1
04/20/2021
Special inspection requirement — Structural Cold-Formed Steel
Erik Madsen
04/19/2021
Filed — Alteration
FILING HEREWITH FOR THE RENOVATION OF APARTMENT 5B.
M00487691-I1
04/09/2021
Filed — Alteration
FILING FOR MECHANICAL SYSTEMS
M00488434-I1
04/01/2021
Violation issued (HPD, closed)
A
04/01/2021
Violation issued (HPD, closed)
I
03/30/2021
Special inspection requirement — Lighting controls
Nicolas Crosetto
03/30/2021
Special inspection requirement — Interior lighting power
Nicolas Crosetto
03/30/2021
Special inspection requirement — Energy Code Compliance Inspections
Nicolas Crosetto
03/30/2021
Special inspection requirement — Permanent certificate
Nicolas Crosetto
03/30/2021
Special inspection requirement — Duct leakage testing, insulation and design
Nicolas Crosetto
03/30/2021
Special inspection requirement — Maintenance information
Nicolas Crosetto
03/30/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
Nicolas Crosetto
03/24/2021
Special inspection requirement — Structural Steel - Details
Erik Madsen
03/24/2021
Special inspection requirement — Masonry
Erik Madsen
03/24/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
Erik Madsen
03/24/2021
Special inspection requirement — Masonry
Nicolas Crosetto
03/24/2021
Special inspection requirement — Energy Code Compliance Inspections
Nicolas Crosetto
03/18/2021
Special inspection requirement — Final
Nicolas Crosetto
03/18/2021
Special inspection requirement — Final
Erik Madsen
Latest 60 of 81 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offL&T Consultants06/18/2026
DOB NOWGeneral ConstructionSigned-offL&T Consultants01/14/2026
DOB NOWGeneral ConstructionSigned-offL&T Consultants12/23/2022
DOB NOWMechanical SystemsSigned-offT.S.M. Mechanical10/18/2022
DOB NOWPlumbingSigned-offAL Plumbing & Cont06/08/2022
DOB NOWGeneral ConstructionSigned-offBest Demo06/07/2022
BISPLISSUEDCalray Gas Heat06/20/2025
BISPLISSUEDNew York Standard Mechanical03/07/2017
BISPLISSUEDQMB Plumbing & Heating02/01/2016
BISOTISSUEDHNL Construction Company12/18/2015
BISOTISSUEDRoco G.C08/24/2015
BISPLISSUEDMagnum Plumbing & Heating07/09/2015
BISMHISSUEDWBPM06/23/2015
BISOTISSUEDWBPM06/23/2015
BISPLISSUEDDC Building Services06/29/2012
BISPLISSUEDDC Building Services04/19/2012
BISOTISSUEDRoco G.C03/19/2012
BISOTISSUEDRoco G.C08/30/2010
BISOTISSUEDRoco G.C07/23/2010
BISOTISSUEDRoco G.C12/17/2008
BISOTISSUEDAircon Heating & Cooling01/16/2007
BISOTISSUEDDVS Iron & Aluminum Works05/25/2006
BISPLISSUEDAnchor Plumbing08/25/2005
BISMHISSUEDMele Contracting07/19/2005
BISOTISSUEDP.D.P. Contracting10/07/2004
BISOTISSUEDP.D.P. Contracting06/03/2004
BISPLISSUEDNew York Standard Mechanical04/23/2004
BIS—ISSUEDDowntown Domain03/02/2004
BISOTISSUEDBarone Steel Fabr03/18/2003
BISOTISSUEDNagel Roofing02/05/2003
BISMHISSUEDP.M. Parker Construction01/31/2003
BISEQISSUEDRockledge Scaffold08/27/2001
BISPLISSUEDTMJ PLG Heating02/09/2000
BISOTISSUEDBFC Construction04/21/1999
1 project · most recent 04/09/2021
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
04/09/2021——Air Conditioning Systems
Cooling
Friedrich VHA18K 675 CFM · Ptac ×1
2 projects · most recent 05/23/2022
General Wiring
FiledStatusContractorScope
05/23/2022Permit IssuedPLM Electric—
05/23/2022Permit IssuedPLM ElectricGeneral Wiring
2 projects · most recent 10/28/2025
Steel Concrete
FiledStatusContractorScope
10/28/2025——Steel, Concrete
04/23/2021——Steel
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
05/23/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/23/2022Pass-Final PL - Up to 9 Requested FloorsPassView ↗
10/21/2022Pass-Final PL - Up to 9 Requested FloorsPassView ↗
10/06/2022Fail-Final PL - Up to 9 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
01/15/2025Tenant Protection Plan ComplianceNOEL WONGspecial
01/15/2025FinalNOEL WONGprogress
05/13/2022HVAC-R and service water heating equipmentKING WONGenergy_progress
05/13/2022Mechanical SystemsKING WONGspecial
05/13/2022FinalKING WONGprogress
05/13/2022HVAC-R and service water heating system controlsKING WONGenergy_progress
05/13/2022Ventilation and air distribution systemKING WONGenergy_progress
05/13/2022HVAC-R and service water piping design and insulationKING WONGenergy_progress
05/13/2022Maintenance informationKING WONGenergy_progress
05/13/2022Duct leakage testing, insulation and designKING WONGenergy_progress
05/11/2022Fire-Resistance Rated ConstructionKING WONGprogress
05/11/2022Lighting in dwelling unitsKING WONGenergy_progress
05/11/2022Fire-Resistant Penetrations and JointsKING WONGspecial
05/11/2022FinalKING WONGprogress
05/11/2022Energy Code Compliance InspectionsKING WONGprogress
04/20/2021Structural Cold-Formed SteelErik Madsenspecial
03/30/2021Lighting controlsNicolas Crosettoenergy_progress
03/30/2021Interior lighting powerNicolas Crosettoenergy_progress
03/30/2021Energy Code Compliance InspectionsNicolas Crosettoprogress
03/30/2021Permanent certificateNicolas Crosettoenergy_progress
03/30/2021Duct leakage testing, insulation and designNicolas Crosettoenergy_progress
03/30/2021Maintenance informationNicolas Crosettoenergy_progress
03/30/2021HVAC-R and service water piping design and insulationNicolas Crosettoenergy_progress
03/24/2021Structural Steel - DetailsErik Madsenspecial
03/24/2021MasonryErik Madsenspecial
Latest 25 of 32.
▾Documents — 194 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/03/2026M00488434-I1Request digital key ↗
09/03/2026M00487691-I1Request digital key ↗
09/03/2026M00488431-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits29
▸BISWORK PERMIT APPLICATION15
06/23/2025103714544Open ↗
05/02/2025103714544Open ↗
02/03/2016122535710Open ↗
Showing 3 of 15 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION14
11/18/2025103714544Open ↗
02/18/2025103714544Open ↗
10/16/2015122535710Open ↗
Showing 3 of 14 on file for this type
▸Zoning, Tax Lot & Property Records1
▸BISZONING DIAGRAM1
01/07/2015122232137Open ↗
▸Seals & Professional Certifications59
▸DOB NOWProgress Inspector Seal & Signature22
09/18/2026M00488434-I1Open ↗
09/18/2026M00488434-I1Open ↗
09/18/2026M00488434-I1Open ↗
Showing 3 of 22 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION18
03/13/2017122382242Open ↗
03/13/2017122382242Open ↗
02/27/2017122382242Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/03/2026M00488434-I1Open ↗
09/03/2026M00487691-I1Open ↗
08/17/2026M01390823-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/18/2026M00488434-I1Open ↗
09/01/2026M00738202-I1Open ↗
08/31/2026M01167606-I1Open ↗
Showing 3 of 5 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
08/11/2015140375608Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/11/2015140375608Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/30/2008110375969Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/11/2015140375608Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/30/2008110375969Open ↗
▸Trade Schedules & Equipment11
▸BISSELF-CERT PLUMBING NOTICE5
11/10/2015122382242Open ↗
07/05/2012121012233Open ↗
05/07/2012121012233Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
10/16/2015122535710Open ↗
05/06/2015122382242Open ↗
01/07/2015122232137Open ↗
▸BISSCHEDULE B - PLUMBING3
09/25/2013121789092Open ↗
03/21/2012121012233Open ↗
06/28/2010120398042Open ↗
▸Safety & Tenant Protection2
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
07/13/2015122382242Open ↗
▸BISSTREET TREE CHECKLIST1
09/25/2013121789092Open ↗
▸Environmental & Asbestos17
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
09/03/2026M00488434-I1Open ↗
09/03/2026M00487691-I1Open ↗
08/17/2026M01390823-I1Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)5
10/16/2015122535710Open ↗
08/11/2015140375608Open ↗
05/06/2015122382242Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
03/21/2012121012233Open ↗
06/28/2010120398042Open ↗
10/30/2008110375969Open ↗
▸Energy Compliance13
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS6
07/20/2016122535710Open ↗
07/19/2016122382242Open ↗
12/31/2015122535710Open ↗
Showing 3 of 6 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
07/19/2016122382242Open ↗
10/05/2015140375608Open ↗
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026M00736050-I1Open ↗
08/13/2026M00738202-I1Open ↗
▸BISTECHNICAL REPORT: ENERGY1
03/21/2012121012233Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
08/11/2015140375608Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
08/11/2015140375608Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
08/12/2015140375608Open ↗
08/11/2015140375608Open ↗
▸Approvals, Objections & Sign-offs15
▸BISLETTERS - SUPPORTING DOCUMENTATION5
06/23/2025103714544Open ↗
06/23/2025103714544Open ↗
12/05/2016122382242Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
03/13/2017122382242Open ↗
07/20/2016122535710Open ↗
10/05/2015140375608Open ↗
Showing 3 of 5 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
03/21/2012121012233Open ↗
06/28/2010120398042Open ↗
10/30/2008110375969Open ↗
▸BISSUPERSEDING LETTER2
06/23/2025103714544Open ↗
05/02/2025103714544Open ↗
▸Cost, Insurance & Ownership17
▸BISCOST AFFIDAVIT15
03/13/2017122382242Open ↗
07/20/2016122535710Open ↗
11/27/2015122535710Open ↗
Showing 3 of 15 on file for this type
▸BISCIVIL PENALTY AFFADAVIT/REQUEST1
08/26/2015140375608Open ↗
▸BISPROJECT-SPECIFIC GL INSURANCE1
07/13/2015122382242Open ↗
▸Filing & Intake Forms13
▸BISEFILING COVER SHEET10
10/16/2015122535710Open ↗
05/06/2015122382242Open ↗
05/06/2015122382242Open ↗
Showing 3 of 10 on file for this type
▸BISBOROUGH INTAKE FORM2
05/27/2025103714544Open ↗
05/02/2025103714544Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
08/11/2015140375608Open ↗
▸Other Documents6
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION4
07/14/2015122382242Open ↗
07/14/2015122382242Open ↗
07/14/2015122382242Open ↗
Showing 3 of 4 on file for this type
▸BISPLOT DIAGRAM2
01/07/2015122232137Open ↗
09/26/2013121789092Open ↗