HPD06/15/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD06/15/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD06/15/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD06/15/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD10/18/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD08/21/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD07/21/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD07/15/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD02/20/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD02/20/2024HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD06/23/2023HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS FRONT YARD
HPD04/11/2023HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/11/2023HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD01/15/2023§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING, TOTAL 6 SQ FT IN THE 1st ROOM FROM EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 15673884 ISSUED 15-JAN-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
ECB09/20/2021UNLAWFUL ACTS,FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.FAILURE TO CORRECT AND CERTIFY SUMMONS#35331851X WORK WITHOUT A PERMIT ANDSUMMONS#35331852H FAILURE TO GROUND ELETRICAL SYSTEMS.REMEDY;COMPLY WI$12K due
DOB08/22/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/26/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB05/23/2019FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED: AT EXPOSURE #3 (REAR YARD), EXCESSIVE ACCUMITATION OF MATTRESS, BED FRAME, PLASTIC BINS AND OTHER VARIOUS ITEMS; DEBRIS, AT EXPOSURE #2, GARBAGE BAG$12K due
DOB05/16/2019FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB03/29/2019FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT EXP#3(RAR YARD)EXCESSIVE ACCUMILATION OF MATTRESS,VED FRAMES,PLASTIC BINS & OTHER VARIOUS ITEMS/DEBRIS AT EXP#2 EXCESSIVE ACCUMILATION OF GARBAGE/GAR$12K due
ECB02/02/2019FAILURE TO MAINTAIN BUILDING CODE COMPLIANT MANNER.2TIME OF INSPECTIONNOTED:EXSESIVE ACCUMILATION OF MATTRESS AND BED FRAME @REAR YARD EXP#3AND ACCUMILATION OF GARBAGE, DEBRIS, ITEMS PARTIALY OBSTRUCTING EGRESS$6K due
DOB09/19/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/19/2018FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB06/25/2018FAILURE TO GROUND ELECTRICAL SYSTEMS.I OBSERVED IN THE ELECTRICAL CLOSET ON THE GROUND FLOOR,A NEW SERVICE SWITCH PANEL COMBO WITHOUT A GROUNDING ELECTRODE CONDUCTOR AND A MAIN BONDING JUMPER.REM:PROVIDE GROUND$24K due
ECB06/25/2018SEC. 314.25 ELECTRICAL BOXES MISSING COVERS, I OBSERVED IN THE ELECTRICAL CLOSET ON GROUND FLOOR NEW & OLD SERVICE SWITCH PANEL COMBOS MISSING COVERS W/EXPOSED ENERGIZED PARTS SUBJECT TO UNNECESSARY TOUCH BY$800 due
ECB06/19/2018WORK WITHOUT A PERMIT.I OBSERVED IN THE ELECTRICAL CLOSET ON THE GROUND FLOOR A NEW SERVICE SWITCH PANEL COMBO NEW FEEDERS AND NEW ARMORED CABLES APPROXIMATELY 80%COMPLETED WITHOUT A PERMIT.PLEASE NOTE:APPLICAT$8K due
HPD01/23/2018§ 27-2005 ADM CODE PROVIDE A FIRE WATCH FOR THE ENTIRE BUILDING
DOB01/11/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB04/07/2016VP-VIOLATION UNSERVED ECB-ACTIVE
DOB04/07/2016VP-VIOLATION UNSERVED ECB-ACTIVE
DOB04/07/2016VP-VIOLATION UNSERVED ECB-ACTIVE
ECB10/16/2016FAILURE TO MAINTAIN BDLG IN CODE COMPLIANT MANNER.NOTED:WROUGHT IRON FENCE/GATE @ FRONT APPROX. 10" LEANING(INSTALLESD)OUTWARD ON TO PUBLIC SIDEWALK.REM:MAKE NECESSARY REPAIRS.Nothing owed — awaiting certificate of correction
ECB09/09/2016FENCE EXCEEDS 6 FOOT PERMITTED HEIGHT. NOTED: FENCE/GATE @ DRIVEWAY IS 7'1" HIGH @ TIME OF INSPECTION. REMEDY: CONFORM FENCE TO CODE.Nothing owed — awaiting certificate of correction
ECB09/09/2016VIOLATION OF PARKING REGULATIONS IN A RESIDENTIAL DISTRICT IS R5. NOTE: 2 WHITE PICKUPS IN DRIVEWAY W/O PLATES BEING USED AS DEAD STORAGE. REMEDY: CONFORM W/PARKING REGULATIONS.Nothing owed — awaiting certificate of correction