← Back
One story retail building
726 MANHATTAN AVENUE
BROOKLYN · BIN 3065657
💬 Discuss this project
1931Year Built
1Stories
K1Building Class
C4-3AZoning
1,450 sfGross Floor Area
1Units
1 Open Violation ▸FDNY Report ↗
One story retail building · Owner of record: R.K.E. LLC · 2,500 sf lot · 0.58 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction33p · 1 filing · 20 docs
Floor 6Under Construction32p · 1 filing · 20 docs
Floor 5Under Construction34p · 1 filing · 20 docs
Floor 4Under Construction33p · 1 filing · 20 docs
Floor 3Under Construction33p · 1 filing · 20 docs
Floor 2Under Construction33p · 1 filing · 20 docs
Floor 1Under Construction32p · 1 filing · 20 docs
CellarUnder Construction35p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JUST CONSULTING ENGINEERING307/29/2026
R & O ENGINEERING107/09/2026
LEANDRO NILS DICKSON ARCHITECT, LLC307/06/2026
VASILIOS ARTEMIOU PE312/23/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPEDITING 4 U403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
COUNTYWIDE BUILDERS INCGeneral Contractor409/16/2026
METFLOW FIRE CONTROL LLCFire Protection109/09/2026
TARGET PIPING NY LLCFire Protection109/09/2026
B&B MECH PLBG & HTG LLCPlumbing109/12/2026
CREATIVE PLUMBING INPlumbing109/13/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616307/06/2026
Building Lifecycle
All (129)Filed (10)Permit Issued (8)Violation (8)Objection (73)Special Inspection (30)
09/15/2026
Permit issued — Foundation
B01278224-S8-FO
09/11/2026
Permit issued — Plumbing
B01278224-S5-PL
09/10/2026
Permit issued — Plumbing
B01278224-S5-PL
09/08/2026
Permit issued — Sprinklers
B01278224-S6-EW-SP
09/08/2026
Permit issued — Sprinklers
B01278224-S6-EW-SP
08/24/2026
Violation issued (ECB, open)
Construction
08/23/2026
Objection resolved — Resolved
08/23/2026
Objection resolved — Resolved
08/21/2026
Objection raised — Other
08/20/2026
Permit issued — Mechanical Systems
B01278224-S4-MS
08/20/2026
Objection raised — Other
08/20/2026
Objection resolved — Resolved
08/19/2026
Objection resolved — Resolved
08/07/2026
Objection raised — Other
08/06/2026
Permit issued — General Construction
B01278224-I1-GC
08/05/2026
Special inspection requirement — Protection of exposed foundation insulation
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Insulation placement and R values
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Interior lighting power
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Lighting controls
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Energy Code Compliance Inspections
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Exterior lighting power
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Air barrier - visual inspection
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Fenestration areas
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Lighting in dwelling units
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Metering
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Fenestration air leakage
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Electrical motors and elevators
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Fire-Resistance Rated Construction
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SHAHRIAR QUAYYUM
08/05/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SHAHRIAR QUAYYUM
08/03/2026
Objection raised — Other
07/30/2026
Objection resolved — Addressed
07/29/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT PLUMBING APPLICATION FILED HEREWITH.
B01278224-S3
07/29/2026
Permit issued — Construction Fence
B01278224-S7-FN
07/29/2026
Objection raised — Cost
07/28/2026
Objection raised — Other
07/28/2026
Objection resolved — Addressed
07/16/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT PLUMBING APPLICATION FILED HEREWITH.
B01278224-S2
07/15/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT PLUMBING APPLICATION FILED HEREWITH.
B01278224-S1
07/09/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT PLUMBING APPLICATION FILED HEREWITH.
B01278224-S8
07/08/2026
Special inspection requirement — Structural Steel - Welding
07/08/2026
Special inspection requirement — Underpinning and alternate methods of support of buildings and adjacent property
07/08/2026
Special inspection requirement — Structural Steel - High Strength Bolting
07/08/2026
Special inspection requirement — Post-installed Anchors
07/08/2026
Special inspection requirement — Structural Steel - Details
07/08/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
07/08/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
07/06/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT PLUMBING APPLICATION FILED HEREWITH.
B01278224-P1
07/06/2026
Special inspection requirement — Maintenance information
SHAHRIAR QUAYYUM
07/06/2026
Special inspection requirement — Lighting in dwelling units
SHAHRIAR QUAYYUM
07/06/2026
Special inspection requirement — Fenestration air leakage
SHAHRIAR QUAYYUM
07/06/2026
Special inspection requirement — Metering
SHAHRIAR QUAYYUM
07/06/2026
Special inspection requirement — Insulation placement and R values
SHAHRIAR QUAYYUM
03/27/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
SUBSEQUENT PLUMBING APPLICATION FILED HEREWITH.
B01278224-S7
03/27/2026
Objection resolved — Resolved
03/27/2026
Objection resolved — Resolved
03/27/2026
Objection resolved — Resolved
Latest 60 of 129 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationPermit IssuedCOUNTYWIDE BUILDERS INC09/15/2026
DOB NOWPlumbingPermit IssuedCREATIVE PLUMBING IN09/11/2026
DOB NOWPlumbingPermit IssuedB&B MECH PLBG & HTG LLC09/10/2026
DOB NOWSprinklersPermit IssuedMETFLOW FIRE CONTROL LLC09/08/2026
DOB NOWSprinklersPermit IssuedTARGET PIPING NY LLC09/08/2026
DOB NOWMechanical SystemsPermit IssuedCOUNTYWIDE BUILDERS INC08/20/2026
DOB NOWGeneral ConstructionPermit IssuedCOUNTYWIDE BUILDERS INC08/06/2026
DOB NOWConstruction FencePermit IssuedCOUNTYWIDE BUILDERS INC07/29/2026
BISFPISSUEDACTIVE FIRE EXTINGUISHER CO INC09/10/2002
1 project · most recent 07/29/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/29/2026Permit IssuedCOUNTYWIDE BUILDERS INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Daikin RXTA24AAVJU 24,000 BTU · Vrf Outdoor ×3
RXTA48AAVJU 48,000 BTU · Vrf Outdoor ×2
RXTA60AAVJU 57,500 BTU · Vrf Outdoor ×1
RZA18AAVJU 18,000 BTU · Condensing Unit ×1
Heating
Daikin RXTA24AAVJU 27,000 BTU · Vrf Outdoor ×3
RXTA48AAVJU 52,000 BTU · Vrf Outdoor ×2
RXTA60AAVJU 57,000 BTU · Vrf Outdoor ×1
RZA18AAVJU 20,000 BTU · Condensing Unit ×1
Ventilation
Nutone PTE511RK 50 CFM · Exhaust Fan ×1
1 project · most recent 07/29/2026
Sprinkler System
FiledStatusContractorScope
07/29/2026Permit IssuedTARGET PIPING NY LLCSprinkler System
1 project · most recent 07/29/2026
Storm Water/Sanitary
FiledStatusContractorScope
07/29/2026Permit IssuedMETFLOW MECHANICAL LLCStorm, Water/Sanitary
1 project · most recent 12/16/2025
General Wiring
FiledStatusContractorScope
12/16/2025Permit IssuedFORSURE ELECTRIC NY INCGeneral Wiring
1 project · most recent 07/29/2026
Concrete
FiledStatusContractorScope
07/29/2026Permit IssuedCOUNTYWIDE BUILDERS INCConcrete
▾Special Inspection Requirements (DOB NOW) — 74
DateRequirementInspectorRole
08/05/2026Fire-Resistant Penetrations and JointsSHAHRIAR QUAYYUMspecial
08/05/2026Fenestration areasSHAHRIAR QUAYYUMenergy_progress
08/05/2026Electrical motors and elevatorsSHAHRIAR QUAYYUMenergy_progress
08/05/2026Fenestration air leakageSHAHRIAR QUAYYUMenergy_progress
08/05/2026Fire-Resistance Rated ConstructionSHAHRIAR QUAYYUMprogress
08/05/2026Energy Code Compliance InspectionsSHAHRIAR QUAYYUMprogress
08/05/2026Exterior Insulation and Finish Systems (EIFS)SHAHRIAR QUAYYUMspecial
08/05/2026Structural Stability – Alterations of existing buildingsSHAHRIAR QUAYYUMspecial
08/05/2026Lighting in dwelling unitsSHAHRIAR QUAYYUMenergy_progress
08/05/2026Insulation placement and R valuesSHAHRIAR QUAYYUMenergy_progress
08/05/2026MeteringSHAHRIAR QUAYYUMenergy_progress
08/05/2026Interior lighting powerSHAHRIAR QUAYYUMenergy_progress
08/05/2026Fenestration and door U-factor and product ratingsSHAHRIAR QUAYYUMenergy_progress
08/05/2026Air barrier - visual inspectionSHAHRIAR QUAYYUMenergy_progress
08/05/2026Lighting controlsSHAHRIAR QUAYYUMenergy_progress
08/05/2026Protection of exposed foundation insulationSHAHRIAR QUAYYUMenergy_progress
08/05/2026Maintenance informationSHAHRIAR QUAYYUMenergy_progress
08/05/2026Exterior lighting powerSHAHRIAR QUAYYUMenergy_progress
07/08/2026Subsurface Investigations (Borings/Test Pits)—special
07/08/2026Underpinning and alternate methods of support of buildings and adjacent property—special
07/08/2026Subsurface Conditions – Fill Placement & In-Place Density—special
07/08/2026Structural Steel - Details—special
07/08/2026Structural Steel - High Strength Bolting—special
07/08/2026Structural Steel - Welding—special
07/08/2026Post-installed Anchors—special
Latest 25 of 74.
▾Documents — 62 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/19/2026B01278224-S4Request digital key ↗
08/19/2026B01278224-S3Request digital key ↗
08/19/2026B01278224-S2Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
09/18/2008310200261Open ↗
▸BISWORK PERMIT APPLICATION1
09/23/2008310200261Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram3
08/19/2026B01278224-I1Open ↗
08/14/2026B01278224-P1Open ↗
08/13/2026B01278224-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)2
08/19/2026B01278224-I1Open ↗
08/14/2026B01278224-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/19/2026B01278224-I1Open ↗
▸Seals & Professional Certifications22
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/19/2026B01278224-S5Open ↗
08/19/2026B01278224-S4Open ↗
08/19/2026B01278224-S3Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026B01278224-P1Open ↗
08/27/2026B01278224-I1Open ↗
08/27/2026B01278224-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/23/2026B01278224-P1Open ↗
09/23/2026B01278224-P1Open ↗
08/27/2026B01278224-I1Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/19/2026B01278224-I1Open ↗
08/14/2026B01278224-P1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/19/2026B01278224-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/19/2026B01278224-S5Open ↗
08/19/2026B01278224-S4Open ↗
08/19/2026B01278224-I1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
09/18/2008310200261Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/19/2026B01278224-S7Open ↗
▸Inspections & Test Reports2
▸DOB NOWSOIL REPORT2
08/19/2026B01278224-S2Open ↗
08/19/2026B01278224-S8Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
09/18/2008310200261Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/18/2008310200261Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/18/2008310200261Open ↗
▸Other Documents7
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/19/2026B01278224-I1Open ↗
08/14/2026B01278224-P1Open ↗
08/13/2026B01278224-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/14/2026B01278224-P1Open ↗
08/13/2026B01278224-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/14/2026B01278224-P1Open ↗
08/13/2026B01278224-I1Open ↗