← Back
Two stories - detached, small or mid-size
73-04 193 STREET
QUEENS · Fresh Meadows-Utopia · BIN 4154253
💬 Discuss this project
1940Year Built
2Stories
A1Building Class
R2AZoning
1,560 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 3,700 sf lot · 0.42 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/20/2022$1000K—Private party → Private party$641/sf building
07/28/2016$749K—HIIC BUILDERS LLC → Private party$480/sf building
03/18/2016$620K—— → —$398/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
XIE ENGINEERING, P.C.308/01/2021
Building Lifecycle
All (20)Filed (3)Objection (2)Special Inspection (15)
08/17/2021
Objection raised — Other
08/17/2021
Objection resolved — Addressed
08/01/2021
Filed — Alteration
Q00552964-I1
08/01/2021
Filed — Alteration
PROPOSED TO REMOVE AND INSTALL PLUMBING FIXTURE FOR ENTIRE BUILDING. THE JOB IS CONJUNCTION WITH JOB@. THERE IS NO CHANGE OCCUPANCY, USE OR EGRESS.
Q00552956-I1
07/26/2021
Filed — Alteration CO
Proposed horizontal extension under the existing 2-story building. Convert the garage to living space. Make the interior renovation as the plan shown and obtain new C. of O.
Q00551936-I1
07/06/2021
Special inspection requirement — Concrete - Cast-In-Place
07/06/2021
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
07/06/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/06/2021
Special inspection requirement — Subgrade Inspections
07/06/2021
Special inspection requirement — Underpinning
07/06/2021
Special inspection requirement — Energy Code Compliance Inspections
07/06/2021
Special inspection requirement — Insulation placement and R values
07/06/2021
Special inspection requirement — Lighting in dwelling units
07/06/2021
Special inspection requirement — Fenestration areas
07/06/2021
Special inspection requirement — Permanent certificate
07/06/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
07/06/2021
Special inspection requirement — Fenestration air leakage
07/06/2021
Special inspection requirement — Protection of exposed foundation insulation
07/06/2021
Special inspection requirement — Lighting controls
07/06/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISPLISSUEDR.J. WELLBROCK INC.05/21/1993
BIS—ISSUEDN/A02/19/1993
1 project · most recent 08/01/2021
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/01/2021——Gas, Storm, Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
07/06/2021Concrete - Cast-In-Place—special
07/06/2021Excavations - Sheeting, Shoring, and Bracing—special
07/06/2021Fire-Resistant Penetrations and Joints—special
07/06/2021Subgrade Inspections—special
07/06/2021Underpinning—special
07/06/2021Energy Code Compliance Inspections—progress
07/06/2021Insulation placement and R values—energy_progress
07/06/2021Lighting in dwelling units—energy_progress
07/06/2021Fenestration areas—energy_progress
07/06/2021Permanent certificate—energy_progress
07/06/2021HVAC-R and service water piping design and insulation—energy_progress
07/06/2021Fenestration air leakage—energy_progress
07/06/2021Protection of exposed foundation insulation—energy_progress
07/06/2021Lighting controls—energy_progress
07/06/2021Fenestration and door U-factor and product ratings—energy_progress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/27/2026Q00551936-I1Request digital key ↗
08/27/2026Q00552964-I1Request digital key ↗
08/14/2026Q00552956-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
10/18/2016421355081Open ↗
▸Zoning, Tax Lot & Property Records2
▸BISZONING DIAGRAM1
10/20/2016421355081Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00551936-I1Open ↗
▸Seals & Professional Certifications6
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
10/19/2016421355081Open ↗
10/19/2016421355081Open ↗
09/19/2016421355081Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/27/2026Q00552964-I1Open ↗
08/13/2026Q00552956-I1Open ↗
08/13/2026Q00551936-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
10/18/2016421355081Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST1
09/19/2016421355081Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00551936-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00551936-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q00552956-I1Open ↗
08/13/2026Q00551936-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/19/2016421355081Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
09/19/2016421355081Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: SOIL INSPECTION1
10/19/2016421355081Open ↗
▸Approvals, Objections & Sign-offs1
▸BISSCHEDULE A - OCCUPANCY / USE1
09/19/2016421355081Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/19/2016421355081Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION3
11/03/2016421355081Open ↗
10/19/2016421355081Open ↗
10/19/2016421355081Open ↗
▸BISEFILING COVER SHEET1
09/19/2016421355081Open ↗
▸Other Documents3
▸BISPLOT DIAGRAM1
09/19/2016421355081Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q00551936-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00551936-I1Open ↗