Walk-up apt, over six families with stores · Owner of record: Zemund Realty · 5,175 sf lot · 5.21 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof5p · 1 filing · 3 docs
Floor 1Tea Two Tea14p · 4 filings · 20 docs
CellarFirst floor commercial tenant space renovation3p · 1 filing · 13 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Zemund Realty2303/22/2026
Lululala607/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Adel Sageer Architect405/21/2026
Jong Hae Chang Architect309/09/2024
Mje Professional Services109/06/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
C Plus Design Group403/21/2026
PS Engineers203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Reliable EnterprisesScaffold407/08/2026
Amko Electric Construction & Maintenance IElectrical203/21/2026
C Plus Design GroupGeneral Contractor107/08/2026
Zaq ConstructionGeneral Contractor104/09/2026
HP ServicesPlumbing107/08/2026
I Do Plumbing & HeatingPlumbing107/08/2026
Atlas-Acon Electric ServiceElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Zheng & Associates7330405/21/2026
JKM Architecture8906309/09/2024
Building Lifecycle
All (65)Filed (9)Permit Issued (7)Signed Off (1)Violation (34)Inspection (4)Special Inspection (10)
09/28/2026
Violation issued (ECB, open)
Construction
06/08/2026
Signed off — Alteration
INTERIOR RENOVATIONA AT EXT. TEA SHOP AT 1ST FLOOR. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
M01373733-I1
05/21/2026
Filed — Alteration
INTERIOR RENOVATIONA AT EXT. TEA SHOP AT 1ST FLOOR. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
M01373733-P1
05/21/2026
Filed — Alteration
MINOR PLUMBING WORK RELATED TO DOB JOB# M01373733. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
M01373774-P1
05/21/2026
Special inspection requirement — Tenant Protection Plan Compliance
Jinfar Liu
05/21/2026
Special inspection requirement — Tenant Protection Plan Compliance
Jinfar Liu
05/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jinfar Liu
05/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jinfar Liu
04/03/2026
Permit issued — General Construction
M01373733-I1-GC
04/03/2026
Permit issued — Plumbing
M01373774-I1-PL
03/30/2026
Filed — Alteration
INTERIOR RENOVATIONA AT EXT. TEA SHOP AT 1ST FLOOR. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
M01373733-I1
03/30/2026
Filed — Alteration
MINOR PLUMBING WORK RELATED TO DOB JOB# M01373733. NO CHANGE IN USE, EGRESS AND OCCUPANCY.
M01373774-I1
11/11/2025
Violation issued (HPD, closed)
C
10/07/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
09/30/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/18/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/09/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL TENANT SPACE ON THE FIRST FLOOR. WORK INCLUDES INSTALLATION OF NEW PARTITIONS, FINISHES, KITCHEN EQUIPMENT, AND LIGHT FIXTURES. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M01072504-P1
09/04/2024
Special inspection requirement — Tenant Protection Plan Compliance
09/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Min
08/09/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/29/2024
Permit issued — Plumbing
M01072504-S1-PL
07/24/2024
Permit issued — General Construction
M01072504-I1-GC
07/15/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL TENANT SPACE ON THE FIRST FLOOR. WORK INCLUDES INSTALLATION OF NEW PARTITIONS, FINISHES, KITCHEN EQUIPMENT, AND LIGHT FIXTURES. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M01072504-S1
07/02/2024
Filed — Alteration
INTERIOR RENOVATION OF EXISTING COMMERCIAL TENANT SPACE ON THE FIRST FLOOR. WORK INCLUDES INSTALLATION OF NEW PARTITIONS, FINISHES, KITCHEN EQUIPMENT, AND LIGHT FIXTURES. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
M01072504-I1
07/02/2024
Special inspection requirement — Tenant Protection Plan Compliance
John Min
06/27/2024
Special inspection requirement — Energy Code Compliance Inspections
Jong Hae Kim
06/26/2024
Special inspection requirement — Lighting controls
YOUNGSAM YU
06/26/2024
Special inspection requirement — Interior lighting power
YOUNGSAM YU
02/06/2024
Permit issued — Suspended Scaffold
M00997032-I1-SC
02/01/2024
Filed — Alteration
M00997032-I1
01/10/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/28/2023
Permit issued — Sidewalk Shed
M00929653-I1-SH
10/16/2023
Violation issued (ECB, closed)
Construction
09/06/2023
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
M00929653-I1
09/06/2023
Permit issued — Sidewalk Shed
M00929653-I1-SH
07/07/2023
Violation issued (HPD, closed)
B
07/07/2023
Violation issued (HPD, closed)
C
06/22/2023
Violation issued (HPD, closed)
A
06/22/2023
Violation issued (HPD, closed)
C
06/22/2023
Violation issued (HPD, closed)
B
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/02/2020
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/02/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/07/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/27/2014
Violation issued (HPD, closed)
B
03/28/2012
Violation issued (ECB, closed)
Construction
08/11/2011
Violation issued (FDNY_NOV, closed)
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/23/2006
Violation issued (HPD, open)
C
10/23/2006
Violation issued (HPD, open)
C
10/23/2006
Violation issued (HPD, open)
C
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/30/2001
Violation issued (HPD, open)
B
08/30/2001
Violation issued (HPD, open)
B
08/30/2001
Violation issued (HPD, open)
B
08/30/2001
Violation issued (HPD, open)
B
08/30/2001
Violation issued (HPD, open)
B
08/30/2001
Violation issued (HPD, open)
B
Latest 60 of 65 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offZaq Construction04/03/2026
DOB NOWPlumbingSigned-offHP Services04/03/2026
DOB NOWPlumbingPermit IssuedI Do Plumbing & Heating07/29/2024
DOB NOWGeneral ConstructionSigned-offC Plus Design Group07/24/2024
DOB NOWSuspended ScaffoldPermit IssuedNorthstar Contracting CP02/06/2024
DOB NOWSidewalk ShedPermit IssuedReliable Enterprises11/28/2023
DOB NOWSidewalk ShedPermit IssuedReliable Enterprises09/06/2023
BISFPISSUEDNY Fire06/16/2016
BISPLISSUEDRRP Plumbing03/16/2016
BISOTISSUEDGlobal Group Industries02/26/2016
BISPLISSUEDChinatown Plumbing & Heating01/19/2016
BISMHISSUEDIhome Improvement & Windo12/29/2015
BISEQISSUEDGood Century Construction09/13/2011
BISOTISSUEDGood Century Construction09/13/2011
BISOTISSUEDHappy Garden Construction07/15/2011
BISFPISSUEDNY Fire11/29/2010
BISOTISSUEDVip Supply09/13/2010
BISOTISSUED55C Construction Cop09/16/2008
BISOTISSUEDNew York Sign Contractor09/09/2008
BISFPISSUEDMaster Fire Systems06/08/2005
BISEQISSUEDColgate Scaffolding02/12/1999
BISFSISSUEDNeal M. Rudikoff09/26/1996
BISPLISSUEDCalray Gas Heat09/26/1996
BIS—ISSUEDWon Yip Construction08/27/1990
2 projects · most recent 05/21/2026
Water/Sanitary Gas
FiledStatusContractorScope
05/21/2026Signed-offHP ServicesWater/Sanitary
09/09/2024Permit IssuedI Do Plumbing & HeatingGas, Water/Sanitary
1 project · most recent 09/06/2023
FiledStatusContractorScope
09/06/2023Permit IssuedRichard Neu—
1 project · most recent 09/06/2023
Sidewalk Shed
FiledStatusContractorScope
09/06/2023Permit IssuedReliable EnterprisesSidewalk Shed
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
10/07/2024Pass-Final General Construction Non-Directive 14PassView ↗
09/30/2024Fail-Final General Construction Non-Directive 14FailView ↗
09/18/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/09/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/21/2026Tenant Protection Plan ComplianceJinfar Liuspecial
05/21/2026Tenant Protection Plan ComplianceJinfar Liuspecial
05/21/2026Fire-Resistant Penetrations and JointsJinfar Liuspecial
05/21/2026Fire-Resistant Penetrations and JointsJinfar Liuspecial
09/04/2024Tenant Protection Plan Compliance—special
09/04/2024Fire-Resistant Penetrations and JointsJohn Minspecial
07/02/2024Tenant Protection Plan ComplianceJohn Minspecial
06/27/2024Energy Code Compliance InspectionsJong Hae Kimprogress
06/26/2024Lighting controlsYOUNGSAM YUenergy_progress
06/26/2024Interior lighting powerYOUNGSAM YUenergy_progress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Tea Two TeaRestaurant / Food ServiceFloor 1
Project M01373733 Alteration · LOC Issued · 03/30/2026
Names are taken automatically from the text of each project’s filed documents (title blocks and cover sheets) and screened to exclude owners, landlords and designers. They may be incomplete or wrong; check the filing.
▾Documents — 144 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/29/2026M00929653-I1Request digital key ↗
08/28/2026M00997032-I1Request digital key ↗
08/26/2026M01072504-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits24
▸BISWORK PERMIT APPLICATION12
06/21/2016122535248Open ↗
03/30/2016122663064Open ↗
03/04/2016122663064Open ↗
Showing 3 of 12 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION12
06/03/2016122535248Open ↗
03/17/2016122536853Open ↗
03/01/2016122663064Open ↗
Showing 3 of 12 on file for this type
▸Seals & Professional Certifications35
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION11
10/06/2016122536853Open ↗
04/28/2016122663064Open ↗
03/01/2016122663064Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/29/2026M00929653-I1Open ↗
08/26/2026M01072504-S1Open ↗
08/17/2026M01373774-P1Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
03/01/2016122663064Open ↗
09/26/2011120826008Open ↗
07/19/2011120760337Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
09/26/2011120826008Open ↗
07/19/2011120760337Open ↗
09/13/2010120465558Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026M01072504-I1Open ↗
09/01/2026M01373774-P1Open ↗
08/25/2026M01373774-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026M01072504-I1Open ↗
09/01/2026M01072504-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/01/2016122663064Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE4
03/17/2016122536853Open ↗
03/01/2016122663064Open ↗
02/02/2016122536853Open ↗
Showing 3 of 4 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA1
05/01/2017122535248Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
03/01/2016122663064Open ↗
▸Environmental & Asbestos19
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/26/2026M01072504-S1Open ↗
08/17/2026M01373774-I1Open ↗
08/17/2026M01373774-P1Open ↗
Showing 3 of 7 on file for this type
▸BISTHIS IS NOT AN ASBESTOS PROJECT5
09/26/2011120826008Open ↗
09/26/2011120826008Open ↗
07/19/2011120760337Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)5
06/03/2016122535248Open ↗
03/01/2016122663064Open ↗
11/09/2015122536853Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
11/18/2010120532478Open ↗
08/15/2008110229618Open ↗
▸Energy Compliance10
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
10/06/2016122536853Open ↗
04/28/2016122663064Open ↗
03/01/2016122663064Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
10/06/2016122536853Open ↗
04/28/2016122663064Open ↗
09/30/2011120760337Open ↗
▸BISTECHNICAL REPORT: ENERGY2
09/30/2011120760337Open ↗
07/19/2011120760337Open ↗
▸BISTR8: Energy Code Progress Inspections1
09/26/2011120826008Open ↗
▸Approvals, Objections & Sign-offs12
▸BISADMINISTRATIVE OBJECTIONS6
09/26/2011120826008Open ↗
07/19/2011120760337Open ↗
11/18/2010120532478Open ↗
Showing 3 of 6 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
05/01/2017122535248Open ↗
10/06/2016122536853Open ↗
04/28/2016122663064Open ↗
Showing 3 of 5 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION1
10/06/2016122536853Open ↗
▸Cost, Insurance & Ownership15
▸BISCOST AFFIDAVIT14
05/01/2017122535248Open ↗
10/06/2016122536853Open ↗
06/03/2016122535248Open ↗
Showing 3 of 14 on file for this type
▸BISHIC LICENSE OR AFFIDAVIT1
03/04/2016122663064Open ↗
▸Filing & Intake Forms10
▸BISEFILING COVER SHEET6
06/03/2016122535248Open ↗
03/01/2016122663064Open ↗
11/09/2015122536853Open ↗
Showing 3 of 6 on file for this type
▸BISADDITIONAL INFORMATION2
04/11/2016122536853Open ↗
02/03/2016122536853Open ↗
▸BISeFiling Job Application Cover Sheet2
09/26/2011120826008Open ↗
09/13/2010120465558Open ↗
▸Other Documents4
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
07/02/2012120465558Open ↗
09/30/2011120760337Open ↗
▸DOB NOWManufacturer's Specifications1
08/13/2026M00997032-I1Open ↗
▸DOB NOWCalculations1
08/13/2026M00997032-I1Open ↗