← Back
Lodge room
73 WEST WASHINGTON PLCE
MANHATTAN · BIN 1008897
💬 Discuss this project
1847Year Built
3.5Stories
P2Building Class
R7-2Zoning
4,502 sfGross Floor Area
3Units
Rent Stabilized15 Open Violations ▸
Lodge room · Owner of record: 73 WASH PLACE, LLC · 2,144 sf lot · 2.1 FAR built · Flood zone X
Locations of Work
StructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction5p · 2 filings · 20 docs
Floor 9Under Construction1p · 1 filing · 17 docs
Floor 8
Floor 7
Floor 6
Floor 5Under Construction25p · 3 filings · 20 docs
Floor 4Under Construction25p · 3 filings · 20 docs
Floor 3Under Construction25p · 3 filings · 20 docs
Floor 2Under Construction25p · 3 filings · 20 docs
Floor 1Under Construction27p · 4 filings · 20 docs
CellarUnder Construction20p · 2 filings · 20 docs
BasementUnder Construction1p · 1 filing · 12 docs
Sub-BasementUnder Construction20p · 2 filings · 20 docs
1 job · most recent 02/07/2025
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
02/07/2025Permit IssuedANVA LLCAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric PUHY-P216TSNU-A 18 tons · Vrf Outdoor ×2
Heating
Mitsubishi Electric PUHY-P216TSNU-A 245,000 BTU · Vrf Outdoor ×2
1 job · most recent 08/12/2025
FiledStatusContractorScope
08/12/2025——90 heads
2 jobs · most recent 08/12/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/12/2025———
02/13/2025Permit IssuedBLAZE PLUMBING & HEATINGGas, Storm, Water/Sanitary
1 job · most recent 01/19/2021
FiledStatusContractorScope
01/19/2021CompleteNASH ELECTRIC SERVICES IN—
1 job · most recent 02/17/2021
Steel Concrete Masonry
FiledStatusContractorScope
02/17/2021Permit IssuedANVA LLCSteel, Concrete, Masonry
1 job · most recent 12/14/2020
Scaffold
FiledStatusContractorScope
12/14/2020Permit IssuedREPUBLIC SCAFFOLD&HOIST CScaffold
Building Lifecycle
All (74)Filed (9)Permit Issued (10)Signed Off (1)Violation (35)Inspection (6)Special Inspection (13)
05/01/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
05/01/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/29/2026
Violation issued (HPD, open)
A
03/13/2026
Permit issued — Mechanical Systems
M00407175-I1-MS
03/12/2026
Permit issued — Structural
M00409402-I1-ST
03/09/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/09/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/05/2026
Permit issued — Plumbing
M00407224-I1-PL
11/17/2025
Violation issued (HPD, open)
I
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/15/2025
Permit issued — Structural
M00409402-I1-ST
10/14/2025
Permit issued — Mechanical Systems
M00407175-I1-MS
08/19/2025
Permit issued — Structural
M00409402-I1-ST
08/12/2025
Filed — Alteration
INSTALL NEW SPRINKLER SYSTEM THROUGHOUT A SINGLE FAMILY HOUSE.
M00415628-I1
08/07/2025
Permit issued — Mechanical Systems
M00407175-I1-MS
08/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JACEK SZCZECH
06/04/2025
Violation issued (HPD, open)
A
05/14/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/24/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/20/2025
Permit issued — Plumbing
M00407224-I1-PL
02/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM SUK
02/13/2025
Filed — Alteration
1.INSTALL DOMESTIC HOT WATER HEATER SYSTEM, DOMESTIC HOT/COLD SYSTEM/PIPING, SANITARY/VENT PIPING, GAS PIPING, AND STORM DRAINAGE SYSTEM/PIPING. 2. INSTALL NEW EJECTOR PUMPS FOR CELLAR AND NEW ELEVATOR SUMP PUMP. REMOVAL OF EXISTING 5 BOILERS.
M00407224-P2
02/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
02/10/2025
Special inspection requirement — HVAC and service water heating system controls
JACEK SZCZECH
02/10/2025
Special inspection requirement — HVAC and service water heating equipment
JACEK SZCZECH
02/10/2025
Special inspection requirement — Maintenance information
JACEK SZCZECH
02/10/2025
Special inspection requirement — Mechanical Systems
JACEK SZCZECH
02/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
JACEK SZCZECH
02/10/2025
Special inspection requirement — Final
JACEK SZCZECH
02/10/2025
Special inspection requirement — Shutoff dampers
JACEK SZCZECH
02/10/2025
Special inspection requirement — HVAC insulation and sealing
JACEK SZCZECH
02/07/2025
Filed — Alteration
1.INSTALL DOMESTIC HOT WATER HEATER SYSTEM, DOMESTIC HOT/COLD SYSTEM/PIPING, SANITARY/VENT PIPING, GAS PIPING, AND STORM DRAINAGE SYSTEM/PIPING. 2. INSTALL NEW EJECTOR PUMPS FOR CELLAR AND NEW ELEVATOR SUMP PUMP. REMOVAL OF EXISTING 5 BOILERS.
M00407224-P1
02/07/2025
Filed — Alteration
INSTALL ENERGY RECOVERY UNITS, EXHAUST FANS, SPLIT VRF HEAT PUMP SYSTEM AND DUCTWORK THROUGHOUT THE ENTIRE SINGLE-FAMILY HOME.
M00407175-P1
02/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/22/2024
Violation issued (HPD, open)
I
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/01/2024
Violation issued (HPD, open)
A
11/15/2023
Violation issued (HPD, open)
I
08/31/2023
Signed off — Alteration
INSTALLATION OF A HEAVY DUTY SIDEWALK SHED AS PER PLANS IN CONJUNCTION WITH GENERAL CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH 2014 NYC BUILDING CODE, CHAPTER 33.
M00439649-I1
03/15/2023
Violation issued (HPD, open)
A
11/02/2022
Violation issued (HPD, open)
I
02/16/2022
Violation issued (HPD, open)
I
02/16/2022
Violation issued (HPD, open)
A
04/01/2021
Violation issued (HPD, open)
I
04/01/2021
Violation issued (HPD, open)
A
02/18/2021
Filed — Alteration
INSTALL ENERGY RECOVERY UNITS, EXHAUST FANS, SPLIT VRF HEAT PUMP SYSTEM AND DUCTWORK THROUGHOUT THE ENTIRE SINGLE-FAMILY HOME.
M00407175-I1
02/18/2021
Filed — Alteration
1.INSTALL DOMESTIC HOT WATER HEATER SYSTEM, DOMESTIC HOT/COLD SYSTEM/PIPING, SANITARY/VENT PIPING, GAS PIPING, AND STORM DRAINAGE SYSTEM/PIPING. 2. INSTALL NEW EJECTOR PUMPS FOR CELLAR AND NEW ELEVATOR SUMP PUMP. REMOVAL OF EXISTING 5 BOILERS.
M00407224-I1
02/17/2021
Filed — Alteration
REFRAME EXISTING JOISTS WITH NEW, EXTENSION IN THE REAR, ADDITIONAL PENTHOUSE FLOOR
M00409402-I1
12/16/2020
Permit issued — Sidewalk Shed
M00439649-I1-SH
12/15/2020
Permit issued — Supported Scaffold
M00439696-I1-SF
12/14/2020
Filed — Alteration
INSTALLATION OF A HEAVY DUTY SIDEWALK SHED AS PER PLANS IN CONJUNCTION WITH GENERAL CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH 2014 NYC BUILDING CODE, CHAPTER 33.
M00439649-I1
12/14/2020
Filed — Alteration
INSTALLATION OF A TEMPORARY SCAFFOLD AS PER PLANS IN CONJUNCTION WITH GENERAL CONSTRUCTION. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SCAFFOLD SHALL COMPLY WITH 2014 NYC BUILDING CODE, CHAPTER 33.
M00439696-I1
10/19/2020
Special inspection requirement — Sprinkler Systems
JACEK SZCZECH
11/08/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/25/2019
Violation issued (HPD, open)
I
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/06/2017
Violation issued (HPD, closed)
I
02/24/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/26/2016
Violation issued (HPD, closed)
I
10/01/2015
Violation issued (HPD, closed)
I
Latest 60 of 74 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
73 WASH PLACE3107/08/2026
73 WASHINGTON PLACE1703/21/2026
PROGRESSIVE ERA ASSOCIATION403/21/2026
SABHARWAL PROPERTIES103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/24/2022$8.0M—— → —$1,777/sf building
10/22/2014$10.0M—PROGRESSIVE ERA ASSOCIATION, INC. → 73 WASHINGTON PLACE, LLC$2,221/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KAM CHIU CONSULTING ENGINEER, P.C.608/12/2025
ARUN RIMAL102/17/2021
ASHRAF CORP212/14/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.1403/21/2026
EUROCELT EXPEDITING, INC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ANVA LLCGeneral Contractor607/08/2026
REPUBLIC SCAFFOLD&HOIST CGeneral Contractor407/08/2026
BLAZE PLUMBING & HEATINGPlumbing207/08/2026
PAUL OLSENElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J & M INSPECTIONS LLC8017308/12/2025
WILLIAM SUK ARCHITECTURE3373102/18/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedANVA03/13/2026
DOB NOWStructuralPermit IssuedANVA03/12/2026
DOB NOWPlumbingPermit IssuedBLAZE PLUMBING & HEATING03/05/2026
DOB NOWStructuralPermit IssuedANVA10/15/2025
DOB NOWMechanical SystemsPermit IssuedANVA10/14/2025
DOB NOWStructuralPermit IssuedANVA08/19/2025
DOB NOWMechanical SystemsPermit IssuedANVA08/07/2025
DOB NOWPlumbingPermit IssuedBLAZE PLUMBING & HEATING02/20/2025
DOB NOWSidewalk ShedSigned-offREPUBLIC SCAFFOLD&HOIST C12/16/2020
DOB NOWSupported ScaffoldPermit IssuedREPUBLIC SCAFFOLD&HOIST C12/15/2020
BIS—ISSUEDANVA LLC03/16/2026
BIS—ISSUEDANVA LLC06/18/2025
BIS—ISSUEDSAGE BUILDERS CORP02/14/2024
BIS—ISSUEDANVA LLC10/04/2023
BIS—ISSUEDANVA LLC11/29/2022
BIS—ISSUEDSAGE BUILDERS CORP09/30/2022
BIS—ISSUEDSAGE BUILDERS CORP10/01/2021
BIS—ISSUEDSAGE BUILDERS CORP03/08/2021
BISOTISSUEDTAOCON INC02/01/2016
BISEQISSUEDTAOCON INC11/09/2015
BISPLRE-ISSUEDDONATO PLUMBING GROUP INC10/14/2015
BISOTISSUEDTAOCON INC07/20/2015
BISOTISSUEDTAOCON INC07/20/2015
BISOTISSUEDDUTCHMAN CONTRACTING INC04/17/2015
BISOTISSUEDDUTCHMAN CONTRACTING INC03/17/2015
BIS—ISSUEDNYC CONSTR INC.02/27/2002
BISMHISSUEDPROGRESSIVE ERA ASSOCIATION03/28/1994
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
05/01/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/01/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/09/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/09/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/14/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/24/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
08/06/2025Fire-Resistant Penetrations and JointsJACEK SZCZECHspecial
02/14/2025Fire-Resistant Penetrations and JointsWILLIAM SUKspecial
02/12/2025Fire-Resistant Penetrations and Joints—special
02/10/2025HVAC and service water heating system controls JACEK SZCZECHenergy_progress
02/10/2025HVAC and service water heating equipment JACEK SZCZECHenergy_progress
02/10/2025Maintenance informationJACEK SZCZECHenergy_progress
02/10/2025Mechanical SystemsJACEK SZCZECHspecial
02/10/2025Fire-Resistant Penetrations and JointsJACEK SZCZECHspecial
02/10/2025FinalJACEK SZCZECHprogress
02/10/2025Shutoff dampersJACEK SZCZECHenergy_progress
02/10/2025HVAC insulation and sealing JACEK SZCZECHenergy_progress
02/07/2025Fire-Resistant Penetrations and Joints—special
10/19/2020Sprinkler SystemsJACEK SZCZECHspecial
▾Documents — 168 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch - Plumbing3
08/24/2026M00407224-P2Request digital key ↗
08/24/2026M00407224-P1Request digital key ↗
08/24/2026M00407224-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems2
08/25/2026M00407175-I1Request digital key ↗
08/25/2026M00407175-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
08/22/2026M00415628-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural1
09/04/2026M00409402-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/04/2026M00439649-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/04/2026M00439696-I1Request digital key ↗
▸Applications & Permits33
▸BISWORK PERMIT APPLICATION14
11/10/2025140962493Open ↗
06/18/2025140962493Open ↗
06/10/2025140962493Open ↗
Showing 3 of 14 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION13
10/02/2025140962493Open ↗
10/01/2025140962493Open ↗
08/14/2025140962493Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWLPC Approval/Permit6
08/13/2026M00407224-P2Open ↗
08/13/2026M00407175-I1Open ↗
08/13/2026M00407175-P1Open ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records5
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT2
11/17/2020140962493Open ↗
10/29/2015122391900Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION2
11/17/2020140962493Open ↗
11/09/2015122391900Open ↗
▸BISZONING DIAGRAM1
12/11/2020140962493Open ↗
▸Seals & Professional Certifications38
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/04/2026M00439649-I1Open ↗
08/24/2026M00407224-I1Open ↗
08/24/2026M00407224-P2Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT6
11/17/2020140962493Open ↗
11/02/2015140423478Open ↗
05/12/2015122391900Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
08/23/2026M00407175-I1Open ↗
08/23/2026M00407175-I1Open ↗
08/23/2026M00407175-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
05/12/2015122391900Open ↗
04/13/2015122358395Open ↗
04/13/2015122358395Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/23/2026M00407224-I1Open ↗
08/23/2026M00407175-I1Open ↗
08/23/2026M00407175-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
05/12/2015122391900Open ↗
04/13/2015122358395Open ↗
03/23/2015122336089Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
11/17/2020140962493Open ↗
11/02/2015140423478Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
11/17/2020140962493Open ↗
11/02/2015140423478Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
04/13/2015122358395Open ↗
▸Safety & Tenant Protection7
▸BISSRO MD ANTI-HARASSMENT CHECKLIST3
11/17/2020140962493Open ↗
11/02/2015140423478Open ↗
05/12/2015122391900Open ↗
▸BISSTREET TREE CHECKLIST2
11/17/2020140962493Open ↗
05/12/2015122391900Open ↗
▸BISTENANT PROTECTION PLAN AND NOTES1
11/17/2020140962493Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
11/22/2021140962493Open ↗
▸Environmental & Asbestos8
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
11/02/2015140423478Open ↗
04/13/2015122358395Open ↗
03/23/2015122336089Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
08/13/2026M00415628-I1Open ↗
08/13/2026M00407175-I1Open ↗
08/13/2026M00409402-I1Open ↗
▸BISASBESTOS: VARIANCE (DEP FORM V5)1
02/19/2021140962493Open ↗
▸BISAPPLICANT SHALL PROVIDE 1 ACP-21 FORMPRIOR TO SIGN OFF: TRU2217MN211
08/12/2025140962493Open ↗
▸Energy Compliance14
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
05/12/2015122391900Open ↗
04/13/2015122358395Open ↗
03/23/2015122336089Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
11/17/2020140962493Open ↗
11/02/2015140423478Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
08/05/2025140962493Open ↗
▸BISLIGHTING CONTROLS1
08/05/2025140962493Open ↗
▸BISLIGHTING IN DWELLING UNITS1
08/05/2025140962493Open ↗
▸BISFENESTRATION AIR LEAKAGE1
08/05/2025140962493Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
08/05/2025140962493Open ↗
▸BISINTERIOR LIGHTING POWER1
08/05/2025140962493Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
08/05/2025140962493Open ↗
▸BISAIR SEALING AND INSULATION - TESTING1
08/05/2025140962493Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
11/02/2015140423478Open ↗
▸Inspections & Test Reports12
▸BISTECHNICAL REPORT: RESPONSIBILITY6
08/05/2025140962493Open ↗
08/05/2025140962493Open ↗
11/17/2020140962493Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
11/26/2021140962493Open ↗
▸BISTR2: CONCRETE FIELD TESTING TECHNICAL REPORT1
08/12/2025140962493Open ↗
▸BISTR3: CONCRETE DESIGN MIX TECHNICAL REPORT1
11/22/2021140962493Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
08/05/2025140962493Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
08/05/2025140962493Open ↗
▸BISMASONRY1
08/05/2025140962493Open ↗
▸Approvals, Objections & Sign-offs12
▸BISSUPERSEDING LETTER5
06/18/2025140962493Open ↗
02/14/2024140962493Open ↗
02/22/2016122358395Open ↗
Showing 3 of 5 on file for this type
▸BISLANDMARKS APPROVAL3
11/17/2020140962493Open ↗
11/09/2015122391900Open ↗
11/02/2015140423478Open ↗
▸DOB NOWDEP Variance (V5) letter2
08/13/2026M00407175-I1Open ↗
08/13/2026M00407224-I1Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
11/30/2022140962493Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
05/12/2015122391900Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
11/17/2020140962493Open ↗
05/12/2015122391900Open ↗
04/13/2015122358395Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms16
▸BISEFILING COVER SHEET7
11/18/2020140962493Open ↗
11/04/2020140962493Open ↗
11/04/2020140962493Open ↗
Showing 3 of 7 on file for this type
▸BISBOROUGH INTAKE FORM5
06/18/2025140962493Open ↗
02/06/2024140962493Open ↗
11/30/2022140962493Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET2
11/17/2020140962493Open ↗
11/02/2015140423478Open ↗
▸BISADDITIONAL INFORMATION2
10/02/2025140962493Open ↗
08/14/2025140962493Open ↗
▸Other Documents8
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
11/17/2020140962493Open ↗
11/17/2020140962493Open ↗
▸BISPLOT DIAGRAM2
11/17/2020140962493Open ↗
05/12/2015122391900Open ↗
▸BISCHIMNEYS AND VENTS1
08/05/2025140962493Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
11/17/2020140962493Open ↗
▸BISMAINTENANCE INFORMATION1
08/05/2025140962493Open ↗
▸BISFIREPLACES1
08/05/2025140962493Open ↗